Note:
Remember,
the
drive
letter
must
be
mapped
to
the
root
of
the
NetWare
SYS
volume.
5.
When
you
are
prompted
to
enable
the
QLogic
failover
configuration,
do
not
enable
it.
(IBM
recommends
the
use
of
the
RDAC
multipath
driver
as
the
DS4000
LUN
failover/failback
driver,
in
a
Microsoft
Windows
environment
or
the
Novell
NetWare
native
multipath
device
driver
in
a
NetWare
environment.)
The
following
are
known
limitations.
v
The
DS4000
storage
products
do
not
support
the
use
of
SANSurfer
to
configure
failover
and
failback
paths
or
IO
load
balancing
for
the
DS4000
storage
subsystem
logical
drives
(LUNs)
using
the
QLogic
failover
version
(QLDirect)
of
the
FC
HBA
device
driver
in
Microsoft
Windows
environments.
IBM
only
supports
the
use
of
DS4000
RDAC
multipath
device
driver
in
conjunction
with
the
non-failover
version
of
the
QLogic
FC
HBA
device
driver.
v
The
DS4000
storage
products
do
not
support
the
use
of
LUN
masking
or
HBA
configuration
wizard/functions;
neither
do
the
DS4000
storage
products
support
non-Fibre
Channel
HBA
functions,
such
as
QLogic
SANSwitch
or
iSCSI
HBA
functions.
v
The
QLogic
SANSurfer
Pro
Utility
program
(formerly
known
as
IBM
FAStT
MSJ
program)
must
not
be
left
installed
on
X64
servers
with
Microsoft
Windows
Server
2003
64-Bit
edition,
while
the
servers
are
running
IOs
to
DS4000
storage
subsystems.
Install
the
QLogic
SANSurfer
®
Pro
Utility
program
if
you
need
to
perform
FC
HBA
updates
or
diagnostics;
then,
uninstall
it
immediately
after
you
have
completed
these
tasks.
v
There
is
no
64-Bit
version
of
the
QLogic
SANSurfer
Pro
Utility
program
(formerly
known
as
FAStT
MSJ)
for
Windows
Server
2003
IA64
or
x64
editions.
You
must
use
the
32-Bit
version
of
the
QLogic
SANSurfer
Pro
Utility
program
for
the
Windows
Server
2003
64-Bit
edition.
Uninstall
the
QLogic
SANSurfer
Pro
Utility
program
when
the
diagnostics
are
complete;
otherwise,
the
program
could
cause
the
server
to
crash
in
heavy
IO
loads.
Note:
For
information
about
other
possible
program
limitations,
please
see
the
README
file.
If
you
have
questions
about
installing
the
QLogic
SANsurfer
Pro
Utility,
please
see
the
README
file,
which
may
have
a
name,
for
example,
like
readme_SANsurfer_FAStMSJ_win32_NW.txt
.
Installing
on
the
Linux
platform
Note:
If
SANSurfer
is
already
installed,
uninstall
it
prior
to
installing
a
new
copy.
GUI
installation
To
perform
the
SANSurfer
Pro
Utility
installation
on
a
Linux
platform,
you
must
execute
four
steps.
1.
Open
a
shell
(command
prompt),
and
change
to
the
directory
that
contains
the
installation
file,
which
might
for
example,
be
named
sansurfer2.0.30b62_linux_install-i.bin
.
2.
At
the
prompt,
type
the
command
to
start
the
program
installation
wizard.
sh
./
program_name
where,
program_name
is
sansurfer2.0.30b62_linux_install-i.bin
Chapter
2.
Installing
the
FC
4Gbps
PCI-X
Adapter
device
drivers
and
updating
the
BIOS
code
11
Содержание System Storage DS4000 FC
Страница 2: ......
Страница 8: ...vi IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 10: ...viii IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 12: ...x IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 16: ...xiv IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 26: ...xxiv IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 66: ...40 IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 68: ...42 IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 70: ...44 IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 80: ...54 IBM System Storage DS4000 FC 4Gbps PCI X Single Dual Port HBA Installation and User s Guide...
Страница 83: ......
Страница 84: ...Part Number 39M5599 Printed in USA GC26 7814 00 1P P N 39M5599...