Parameter
Description
T10PIDisabled
The setting to turn on or turn off T10 PI
(Protection Information) for a specific logical
drive. For this parameter to have meaning, your
logical drive must be capable of T10 PI
(Protection Information). This parameter
changes a logical drive from one that supports
T10 PI (Protection Information) to a logical
drive that cannot support T10 PI (Protection
Information).
To remove T10 PI (Protection Information) from
a logical drive that supports T10 PI (Protection
Information), set this parameter to
TRUE
. To
return a logical drive to supporting T10 PI
(Protection Information), set this parameter to
FALSE
.
Note:
If you remove T10 PI (Protection
Information) from a logical drive, you cannot
reset T10 PI (Protection Information) for that
logical drive.
To reset T10 PI (Protection Information) for the
data on a logical drive, from which you
removed T10 PI (Protection Information):
1.
Remove the data from the logical drive.
2.
Delete the logical drive.
3.
Re-create a new logical drive with the
properties of the deleted logical drive.
4.
Set T10 PI (Protection Information) for the
new logical drive.
5.
Move the data to the new logical drive.
addCapacity
The setting to increase the storage size
(capacity) of the logical drive for which you are
defining properties. Size is defined in units of
bytes
,
KB
,
MB
,
GB
, or
TB
. The default value is
bytes
.
addDrives
The setting to add new disk drives to the logical
drive. For high-capacity disk drive expansion
enclosures, specify the enclosure ID value, the
drawer ID value, and the slot ID value for the
disk drive. For low-capacity drive expansion
enclosures, specify the enclosure ID value and
the slot ID value for the disk drive. Enclosure
ID values are
0
to
99
. Drawer ID values are
1
to
5
. Slot ID values are
1
to
32
. Enclose the
enclosure ID value, the drawer ID value, and
the slot ID value in parentheses. Use this
parameter with the
addCapacity
parameter if
you need to specify additional disk drives to
accommodate the new size.
redundancyCheckEnabled
The setting to turn on or turn off redundancy
checking during a media scan. To turn on
redundancy checking, set this parameter to
TRUE
. To turn off redundancy checking, set this
parameter to
FALSE
.
Chapter 3. Script Commands
3-219
Содержание System Storage DS3000
Страница 10: ...x IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 12: ...xii IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 46: ...2 12 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 382: ...3 336 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 476: ...7 16 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 504: ...9 12 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 512: ...10 8 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 530: ...11 18 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 590: ...12 60 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 594: ...13 4 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 596: ...14 2 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 598: ...A 2 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 599: ...Appendix A Examples of information returned by the show commands A 3...
Страница 600: ...A 4 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 601: ...Appendix A Examples of information returned by the show commands A 5...
Страница 602: ...A 6 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 603: ...Appendix A Examples of information returned by the show commands A 7...
Страница 604: ...A 8 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 605: ...Appendix A Examples of information returned by the show commands A 9...
Страница 606: ...A 10 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 607: ...Appendix A Examples of information returned by the show commands A 11...
Страница 608: ...A 12 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 609: ...Appendix A Examples of information returned by the show commands A 13...
Страница 610: ...A 14 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 611: ...Appendix A Examples of information returned by the show commands A 15...
Страница 623: ...Appendix A Examples of information returned by the show commands A 27...
Страница 624: ...A 28 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 625: ...Appendix A Examples of information returned by the show commands A 29...
Страница 626: ...A 30 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 627: ...Appendix A Examples of information returned by the show commands A 31...
Страница 628: ...A 32 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 632: ...B 4 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 648: ...F 4 IBM System Storage DS3000 DS4000 and DS5000 Command Line Interface and Script Commands Programming Guide...
Страница 651: ......
Страница 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...