Table 18. Other expansion enclosure parts (continued)
FRU Part Number
Description
Comments
01LJ126
Fan module
The expansion enclosure contains
four fan modules.
01LJ128
Expansion canister
01LJ130
Cable management arms (CMA)
The part contains the upper and
lower CMA.
01LJ132
Top cover
01LJ134
Fan interface board
01LJ607
Enclosure
Note: Replaces enclosure FRU P/N
01LJ112.
Includes the drive board, signal
interconnect board, and internal
power cables, in an otherwise
empty enclosure.
39M5388
16A power cord C19/C20 2 m
Connecting the components
After installing the rails and enclosures in the rack, the Storwize V5100 control enclosures are connected
to power, the network, and any optional expansion enclosures.
After all cabling connections are completed, the system components are powered on.
Connecting Ethernet cables to the node canisters
To provide system management connectivity for the system, connect Ethernet cables to Ethernet port 1
of both node canisters in the control enclosure.
Procedure
Optionally, connect Ethernet port 2 of each node canister in the system to a second IP network that will
provide redundant connection to the system management interfaces.
This port can also be used for iSCSI connectivity to the system by hosts on the network. If there is more
than one control enclosure in the system, ensure that port 2 of every node canister is connected to the
same network to provide access if the configuration node fails.
Connecting Fibre Channel cables to the control enclosure
If your system has one or more Fibre Channel adapters installed, use Fibre Channel cables to connect the
two node canisters in the enclosure to the switches in the Fibre Channel SAN.
Before you begin
Refer to the "Planning" section of the IBM Knowledge Center for instructions on determining the number
of required cables and their intended port locations.
Procedure
To install the cables, complete the following steps.
1. Referring to the "Planning" section of the documentation, connect the required number of Fibre
Channel cables to the node canisters in the control enclosure
Note: Both canisters must have the same number of cables connected.
Figure 66 on page 56 shows the location of optional Fibre Channel adapters in adapter slot 2 of each
of the two node canisters. The port numbers are also shown.
Chapter 2. Installing the system hardware 55
Содержание Storwize V5100 Series
Страница 12: ...xii Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 20: ...xx Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 24: ...xxiv Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 32: ...8 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 102: ...78 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 104: ...80 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 106: ...82 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 108: ...84 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 114: ...90 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 128: ...104 Storwize V5100 Quick Installation Guide for MTM 2078 424 2078 12F 2078 24F 2078 92F and 2078 U5B...
Страница 129: ......
Страница 130: ...IBM Part Number 02YC382 1P P N 02YC382...