IBM Slicestor 2584 Скачать руководство пользователя страница 37

Notices

This information was developed for products and services offered in the US. This material might be
available from IBM in other languages. However, you may be required to own a copy of the product or
product version in that language in order to access it.

IBM may not offer the products, services, or features discussed in this document in other countries.
Consult your local IBM representative for information on the products and services currently available in
your area. Any reference to an IBM product, program, or service is not intended to state or imply that
only that IBM product, program, or service may be used. Any functionally equivalent product, program,
or service that does not infringe any IBM intellectual property right may be used instead. However, it is
the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or
service.

IBM may have patents or pending patent applications covering subject matter described in this
document. The furnishing of this document does not grant you any license to these patents. You can send
license inquiries, in writing, to:

IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.

For license inquiries regarding double-byte character set (DBCS) information, contact the IBM Intellectual
Property Department in your country or send inquiries, in writing, to:

Intellectual Property Licensing
Legal and Intellectual Property Law
IBM Japan, Ltd.
19-21, Nihonbashi-Hakozakicho, Chuo-ku
Tokyo 103-8510, Japan

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS"
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically
made to the information herein; these changes will be incorporated in new editions of the publication.
IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.

Any references in this information to non-IBM websites are provided for convenience only and do not in
any manner serve as an endorsement of those websites. The materials at those websites are not part of
the materials for this IBM product and use of those websites is at your own risk.

IBM may use or distribute any of the information you provide in any way it believes appropriate without
incurring any obligation to you.

© Copyright IBM Corp. 2016, 2018

23

Содержание Slicestor 2584

Страница 1: ...IBM Cloud Object Storage System Version 3 13 1 Slicestor 2584 Installation Guide IBM...

Страница 2: ...ental notices v The information in the IBM Environmental Notices and User Guide provided on a DVD This edition applies to IBM Cloud Object Storage System Slicestor 2584 and is valid until replaced by...

Страница 3: ...n 5 Before you begin 5 Unpacking the storage system 5 Chapter 3 Installing the appliance into a rack 7 Mounting the system into a rack 7 Enclosure layout 8 Installing and removing disk drives in carri...

Страница 4: ...iv Slicestor 2584 Installation Guide...

Страница 5: ...moving a DDIC 11 8 Removing a cooling module 1 11 9 Removing a cooling module 2 12 10 Removing a PSU 1 12 11 Removing a PSU 2 13 12 Removing a module 1 6Gb s SAS EBOD module shown 13 13 Removing a mod...

Страница 6: ...vi Slicestor 2584 Installation Guide...

Страница 7: ...emissions in accordance with ISO 9296 1 2 3 xiii 2 SBB compute module LED descriptions 17 3 Ops module LED states 18 4 Drawer LED states 19 5 PSU LED states 20 6 Cooling module LED states 21 Copyright...

Страница 8: ...viii Slicestor 2584 Installation Guide...

Страница 9: ...a danger notice Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229 9054 which is included with your product CAUTION A caution notice indicates the presence of...

Страница 10: ...l possible unsafe conditions are corrected Assume that an electrical safety hazard is present Perform all continuity grounding and power checks specified during the subsystem installation procedures t...

Страница 11: ...nditions due to uneven mechanical loading always install the heaviest devices in the bottom of the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinet...

Страница 12: ...the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit For sliding drawers Do not pull o...

Страница 13: ...Model S03 35 deg C room ambient 9 3 9 3 75 75 Model S03 25 deg C room ambient w Acoustical doors Feature codes FC EC07 back FC EC08 front 7 4 7 4 55 55 Model S03 35 deg C room ambient w Acoustical doo...

Страница 14: ...xiv Slicestor 2584 Installation Guide...

Страница 15: ...ection provided by the equipment might be impaired v All rear modules are part of the fire enclosure and must only be removed when a replacement can be immediately added The system must not be run wit...

Страница 16: ...ning both drawers at the same time Do not attempt to force open a drawer when the other drawer is already open Rack system precautions The enclosure must be mounted in a rack Consider the following sa...

Страница 17: ...ing plug in modules and components Avoid contact with backplane components module connectors and other potential sources of ESD Product rating Product rating information can also be found on the back...

Страница 18: ...4 Slicestor 2584 Installation Guide...

Страница 19: ...enclosure ensure that you have the following accessories v Power Cord v Rack kit if installing within a rack Refer to your supplier for a list of qualified accessories for use with the enclosure The a...

Страница 20: ...Figure 1 Unpacking the storage system 6 Slicestor 2584 Installation Guide...

Страница 21: ...les and components Avoid contact with backplane components module connectors and other potential sources of ESD ESD damage is not covered by warranty Note Rail Kit Adjustment Range Inside of the front...

Страница 22: ...e enclosure fully home on its rails 5 Fasten the front of the enclosure using the enclosure fastening screws and washers x4 as shown in Figure 2 6 Fix the rear of the enclosure to the hold down bracke...

Страница 23: ...LEDs on the front of the enclosure and the modules on the back For detailed information about the LEDs see Chapter 4 LED states on page 17 Figure 3 Drive numbering for drawer 1 top Figure 4 Drive num...

Страница 24: ...IC into the slot and then push it down until it stops as shown in the following figure 2 Slide the top latch in the direction of the arrow until the latch clicks into place see Figure 6 Removing a DDI...

Страница 25: ...void damaging the connector pins Do not install if any pins appear to be bent CAUTION Do not remove these modules unless a replacement can be immediately added The system must not be run without all m...

Страница 26: ...remove covers from the PSU Danger of electric shock inside Return the PSU to your supplier for repair 1 Squeeze the retaining latch as shown in the following figure 2 Pull the PSU handle until the uni...

Страница 27: ...he procedure is the same for a SBB compute module 1 Grasp the module latch between the thumb and forefinger and squeeze them together to release the latch as shown in the following figure 2 Pull the l...

Страница 28: ...e new unit 5 Connect the cables to the new module If necessary refer to the note you made before you removed the cables from the defective compute module Battery removal Battery removal To remove the...

Страница 29: ...battery can release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Refer to the IBM Systems Environmental Notices for battery disposal guid...

Страница 30: ...16 Slicestor 2584 Installation Guide...

Страница 31: ...correctly Flashing green when there is an controller VPD error SAS Activity LEDs Steady green when there is a connection but no activity Flashing green when there is a connection and activity Etherne...

Страница 32: ...state X On Off Off Off Off Power on all functions good X On On X Off Off PSU fault LEDs fan fault LEDs Any PSU fault fan fault over or under temperature X On On X Off Off SBB module LEDs Any SBB modul...

Страница 33: ...On Off Fault LED on Drawer 1 Fault present on drawer 1 drive cable or fanout card fault X On X X Off On Fault LED on Drawer 2 Fault present on drawer 2 drive cable or fanout card fault Flashing X X X...

Страница 34: ...full capacity X disregard Power supply unit PSU LEDs Each PSU has its own indicators The following figure shows the LEDs for the power supply Table 5 PSU LED states PSU fail amber AC fail amber Power...

Страница 35: ...the LEDs for a cooling module Table 6 Cooling module LED states Module OK green Fan fault amber Status X Off Fan OK X On Communication lost with fan module controller X On Reported fan speed is out of...

Страница 36: ...22 Slicestor 2584 Installation Guide...

Страница 37: ...CS information contact the IBM Intellectual Property Department in your country or send inquiries in writing to Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan Ltd 19 21...

Страница 38: ...sent goals and objectives only All IBM prices shown are IBM s suggested retail prices are current and are subject to change without notice Dealer prices may vary This information is for planning purpo...

Страница 39: ...torage Insight IBM Cloud Object Storage Manager IBM Cloud Object Storage Slicestor IBM Cloud Object Storage Standard IBM Cloud Object Storage System IBM Cloud Object Storage Vault SecureSlice and Slic...

Страница 40: ...26 Slicestor 2584 Installation Guide...

Страница 41: ......

Страница 42: ...IBM Printed in USA...

Отзывы: