If you are going to use the switch in a single-switch setup, you can use
EZSwitchSetup to complete the basic configuration. See the EZSwitchSetup CD,
included with the switch, for more information.
You can also use the
IBM System Storage SAN42B-R Quick Start Guide
. If you do not
want to use EZSwitch Setup, follow the instructions in this section.
To configure the switch, complete the following tasks.
v
“Providing power to the switch”
v
“Creating a serial connection” on page 23
v
“Setting the switch IP address” on page 23
v
“Changing the switch name and chassis name” on page 24
v
“Creating an Ethernet connection” on page 24
v
“Setting the domain ID of the switch” on page 24
v
“Setting the date and time of the switch” on page 25
v
“Synchronizing local time with an external source” on page 26
v
“Correcting the time zone of a switch” on page 26
v
“FCIP and Fibre Channel routing services configuration” on page 27
v
“Installing SFP+ and QSFP transceivers and connecting cables” on page 27
v
“Verifying correct operation and backing up the configuration” on page 29
Attention:
Do not connect the switch to the network until the IP address is
correctly set.
Providing power to the switch
DANGER
An electrical outlet that is not correctly wired could place
hazardous voltage on metal parts of the system or the devices that
attach to the system. It is the responsibility of the customer to
ensure that the outlet is correctly wired and grounded to prevent
an electrical shock. (D004)
Complete these steps to power on the switch:
1.
Connect the power cords to both power supplies in the chassis.
2.
Connect the other end of the power cords to power sources on separate circuits
to protect against AC failure. Ensure that the cords have a minimum service
loop of 15 cm (6 in.) available and are routed to avoid stress.
The power supplies provide power to the switch as soon as they are connected
to a power source. Each power supply has two LEDs, one for AC status and
one for DC status. Both LEDs turn green within one second of power being
applied. The power status LED on the port side of the switch turns green as
soon as either power supply LED is green. The status LED is amber only until
FOS is loaded and then it turns green. The status LED is green while POST is
running.
Attention:
Power is supplied to the switch as soon as the first power supply
is connected to a power source. There are no switches on the power supplies to
turn the power on and off.
22
SAN42B-R Installation, Service, and User Guide
Содержание SAN42B-R
Страница 2: ......
Страница 6: ...iv SAN42B R Installation Service and User Guide...
Страница 8: ...vi SAN42B R Installation Service and User Guide...
Страница 10: ...viii SAN42B R Installation Service and User Guide...
Страница 22: ...xx SAN42B R Installation Service and User Guide...
Страница 56: ...32 SAN42B R Installation Service and User Guide...
Страница 62: ...38 SAN42B R Installation Service and User Guide...
Страница 72: ...48 SAN42B R Installation Service and User Guide...
Страница 94: ...70 SAN42B R Installation Service and User Guide...
Страница 95: ......
Страница 96: ...Part Number 00MA667 Printed in USA SC27 6633 00 1P P N 00MA667...