Each crossbar fabric module connects to 8 switching modules and 2 supervisor
modules. In addition, each crossbar fabric module supports four 55 Gbps fabric
ports connected to each switching module and one 55 Gbps fabric port connected
to each supervisor module.
The fan modules cover the fabric modules in the back of the chassis. Fan module 1
must be removed to access fabric modules 1 and 2, fan module 2 must be removed
to access fabric modules 3 and 4, and fan module 3 must be removed to access
fabric modules 5 and 6.
The LEDs on the crossbar fabric modules indicate the status of the modules.
Table 6 describes the LEDs.
Table 6. SAN384C-6 Crossbar Modules LEDs
LED
Status
Description
Status
Green
All diagnostics pass. The
module is operational
(normal initialization
sequence).
Orange
One of the following occurs:
The module is booting or
running diagnostics (normal
initialization sequence).
An over-temperature
condition occurred (a minor
threshold was exceeded
during environmental
monitoring).
Red, flashing
One of the following occurs:
The diagnostic test failed.
The module is not
operational because a fault
occurred during the
initialization sequence.
An over-temperature
condition occurred (a major
threshold was exceeded
during environmental
monitoring).
Fabric module has been
manually powered off.
Red
Bad slot ID parity.
Off
The module is not receiving
power.
Locater ID
Blue flashing
Operator has flagged this
card for identification.
Off
Operator has not flagged this
card for identification.
Since the crossbar fabric modules are located behind the fan modules in the
chassis, the LEDs on the crossbar fabric module are not easily visible from the back
Chapter 1. Introducing the IBM c-type SAN Directors
23
Содержание SAN192C-6
Страница 2: ......
Страница 8: ...vi SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 10: ...viii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 24: ...xxii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 114: ...90 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 122: ...98 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 142: ...Figure 44 AJK5 Figure 45 AJJX Figure 46 AJK4 118 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 143: ...Figure 47 AJK2 Figure 48 AJK1 Figure 49 AJJY Appendix B Cable and Port Specifications 119 ...
Страница 144: ...Figure 50 AJJV 120 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 146: ...122 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 158: ...134 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Страница 159: ......
Страница 160: ...IBM Part Number 02JD693 Printed in USA SC27 9276 00 1P P N 02JD693 ...