Table 13. Power supply/fan status LED patterns
LED color
Status of hardware
Recommended action
No light
Power supply/fan assembly is not seated
correctly.
Reseat power supply.
Steady green
Power supply/fan assembly is operating
normally.
No action required.
Flashing green
Power supply/fan assembly fault for one of
the following reasons:
v
The power cable is disconnected
v
Power supply/fan assembly is switched off
v
The power supply has failed
1.
Check the power cable connection.
2.
Verify that the power supply/fan assembly is
powered on.
3.
Run
psShow
and
fanShow
commands to
determine the source of the fault.
If the actions above do not resolve the problem,
replace the power supply/fan assembly.
Interpreting POST results
POST is a system check that is performed each time the switch is powered on,
rebooted, or reset, and during which the LEDs flash different colors.
To determine whether POST completed successfully and whether any errors were
detected:
1.
Verify that the LEDs on the switch indicate that all components are healthy (see
“LED activity” on page 25). If one or more LEDs do not display a healthy state:
a.
Verify that the LEDs are not set to “beacon” (this can be determined
through the
switchShow
command or Web Tools). For information about
how to turn beaconing on and off, see the
Fabric OS Administrator's Guide
or
the
Web Tools Administrator's Guide
.
b.
Follow the recommended action for the observed LED behavior, as listed in
the tables in “LED activity” on page 25.
2.
Verify that
diagShow
command displays that the diagnostic status for all ports
in the switch is OK.
3.
Review the system log for errors. Errors detected during POST are written to
the system log, which is viewed using the
errShow
command. For more
information about this command, see the
Fabric OS Command Reference
. For
information about specific error messages, see the
Fabric OS Message Reference
.
30
SAN06B-R Installation, Service, and User Guide
Содержание SAN06B-R
Страница 2: ......
Страница 8: ...vi SAN06B R Installation Service and User Guide...
Страница 12: ...x SAN06B R Installation Service and User Guide...
Страница 14: ...xii SAN06B R Installation Service and User Guide...
Страница 24: ...xxii SAN06B R Installation Service and User Guide...
Страница 32: ...6 SAN06B R Installation Service and User Guide...
Страница 62: ...36 SAN06B R Installation Service and User Guide...
Страница 68: ...42 SAN06B R Installation Service and User Guide...
Страница 80: ...54 SAN06B R Installation Service and User Guide...
Страница 83: ......
Страница 84: ...Part Number 98Y5370 Printed in USA GC27 2270 02 1P P N 98Y5370...