error may be an ACIF logic error. If you used a program
to create the structured fields for the image object,
contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
image object with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide for
assistance in determining the source of the problem.
APK217S DATA IN AN INPUT RECORD IS INVALID:
PARAMETER IN A BR STRUCTURED
FIELD CONTAINS UNACCEPTABLE
DATA.
Explanation: One of the parameters in the Begin
Resource (BR) structured field is invalid. The BR
structured field is contained in the print data set.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you placed the BR structured field
in the print data set, correct the error and resubmit the
print request. Refer to
Mixed Object Document Content
Architecture Reference for more information about the
structured field. If you used a program to place the BR
structured field in the print data set, contact your system
programmer.
System Programmer Response: If an IBM licensed
program was used to place the BR structured field in
the print data set, verify that the input to that program
was valid. If the input was valid, refer to
Advanced
Function Printing: Diagnosis Guide and the appropriate
Print Services Facility: Diagnosis Guide and Reference
for assistance in determining the source of the problem.
APK221S DATA IN A FORMDEF RESOURCE IS
INVALID: THE ORIENTATION VALUE
value IN THE MDD STRUCTURED FIELD
IS UNACCEPTABLE.
Explanation: The Medium Descriptor (MDD)
structured field has an invalid orientation value. The
MDD structured field is contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the error and resubmit the
print request. Refer to
Mixed Object Document Content
Architecture Reference for more information about the
structured field. If the structured field has no error, the
error may be an ACIF logic error. If you used a program
to create the structured fields for the form definition,
contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide for
assistance in determining the source of the problem.
|
APK244I
DATA IN AN INPUT RECORD OR
|
RESOURCE IS INVALID: THE xxx
|
STRUCTURED FIELD CONTAINS TOO
|
MANY REPEATING GROUPS.
|
Explanation: The structured field contains more
|
repeating groups than are allowed. The structured field
|
in error can be contained in a composed text page, an
|
overlay, or a page definition.
|
System Action: ACIF terminates.
|
User Response: If you created the structured fields
|
for the print data set or the resource, correct the error
|
and resubmit the print request. Refer to
Mixed Object
|
Document Content Architecture Reference for more
|
information about the structured field. If the structured
|
field has no error, the error may be an ACIF logic error.
|
If you used a program to create the structured fields for
|
the print data set or the resource, contact your system
|
programmer.
|
System Programmer Response: If an IBM licensed
|
program was used to create the structured fields for the
|
print data set or the resource with the error, verify that
|
the input to that program was valid. If the input was
|
valid, refer to
Advanced Function Printing: Diagnosis
|
Guide for assistance in determining the source of the
|
problem.
|
APK246S DATA IN AN INPUT RECORD OR
|
RESOURCE IS INVALID: A REQUIRED
|
TRIPLET with ID X
'
4B
'
WAS MISSING
|
FROM AN IOB STRUCTURED FIELD.
|
Explanation: The x or y axis origin for object content
|
or an object area size (X
'
4C
'
) triplet was specified on
|
an IOB but no measurement units (X
'
4B
'
) triplet was
|
specified. The structured field is contained in a print
|
data set or overlay.
|
System Action: ACIF stops processing the input data
|
set.
|
User Response: If you placed the IOB structured field
|
in the input data set or overlay, correct the error and
|
resubmit the ACIF job. Refer to
Mixed Object Document
|
Content Architecture Reference for more information
|
about the structured field. If you used a problem to
|
place the IOB structured field in the print data set or
|
overlay, contact your system programmer.
|
System Programmer Response: No response is
|
necessary.
148
ACIF User’s Guide
Содержание S544-5285-01
Страница 1: ...IBM Print Services Facility IBM AFP Conversion and Indexing Facility User s Guide S544 5285 01...
Страница 2: ......
Страница 3: ...IBM Print Services Facility IBM AFP Conversion and Indexing Facility User s Guide S544 5285 01...
Страница 10: ...viii ACIF User s Guide...
Страница 21: ...Part 1 Information Common to AIX OS 390 MVS VM and VSE Environments Copyright IBM Corp 1993 1999 1...
Страница 22: ...2 ACIF User s Guide...
Страница 40: ...20 ACIF User s Guide...
Страница 41: ...Part 2 Using ACIF in the AIX Environment Copyright IBM Corp 1993 1999 21...
Страница 42: ...22 ACIF User s Guide...
Страница 72: ...52 ACIF User s Guide...
Страница 96: ...76 ACIF User s Guide...
Страница 99: ...Part 3 Using ACIF in the OS 390 MVS VM and VSE Environments Copyright IBM Corp 1993 1999 79...
Страница 100: ...80 ACIF User s Guide...
Страница 106: ...86 ACIF User s Guide...
Страница 134: ...Figure 24 Example of a Customer s Phone Bill 114 ACIF User s Guide...
Страница 142: ...122 ACIF User s Guide...
Страница 196: ...176 ACIF User s Guide...
Страница 197: ...Part 4 Appendixes Copyright IBM Corp 1993 1999 177...
Страница 198: ...178 ACIF User s Guide...
Страница 206: ...186 ACIF User s Guide...
Страница 210: ...190 ACIF User s Guide...
Страница 226: ...206 ACIF User s Guide...
Страница 253: ......
Страница 255: ...Spine information IBM IBM Print Services Facility User s Guide AFP Conversion and Indexing Facility...