Fill Count
. The number of cartridge labels to be added to the end of the list when the
Volume Label
field is next modified. This number may be one or greater. If the list fills up before the
Fill Count
is
exhausted, filling stops, and a message box is displayed (see Maximum Volumes Allowed below).
Fill Increment
. In a multiple-cartridge fill, this field determines how each new cartridge label is
generated from the previous one. A cartridge label is six alphanumeric characters. The
Fill Increment
is
added to the least significant part of a cartridge label to generate a new label.
Volume Label
. The cartridge label to be added to the end of the Volume List. If
Fill Count
is greater
than 1, this will be the first label of a fill sequence. The label must be exactly six characters long.
Maximum Volumes Allowed
. The maximum number of cartridge labels that will be allowed in the
Volume List (10,000).
Total Count
. The total number of labels currently in the Volume List.
Volume List
. A list of cartridge/volume labels specifying the cartridges to be moved. You cannot enter
labels directly into this list, but must construct it in one of the three ways described above. Use the
scrollbar to move up and down the list of labels.
You can select one or more labels from the list for the purpose of removing them from the list (see
Clear
Selected
below).
Buttons
Clear All
. Clears the Volume List, and resets
Fill Count
and
Fill Increment
to 1.
Clear Selected
. If one or more cartridges are selected (highlighted) in the Volume List, clicking on this
button will remove them from the list. Note that this does not actually delete anything from HPSS.
Move Cartridges
. Begins moving the listed cartridges. A start message is displayed on the message line
at the bottom of the window, and all window features are disabled, except for the
Dismiss
button; this
prevents you from modifying any data on the window while the move is in progress.
It is a good idea to have the
HPSS Alarms and Events
window open while moving proceeds, so that all
relevant log messages can be viewed. Move operation initiation, completion and errors will be reported
in the
HPSS Alarms and Events
window.
While moving proceeds, status messages are displayed on the status bar. When the move is finished, a
completion message is displayed and the window features are reenabled. At this point new data can be
entered for a new move.
8.6. Monitoring and Managing Volume Mounts
Volume mounts are performed by the PVL. Every volume mount is associated with a PVL job. The
PVL
Job Queue
window, lists all PVL jobs and the
PVL Request Information
window lists detailed
information about a single PVL job.
The PVL reports every tape mount request in the
Tape Mount Requests
window. Tapes which need to be
returned to the robot from a shelf or vault location are reported in the
Tape Check-In Requests
window.
Each of these windows is described in detail in this section.
HPSS Management Guide
November 2009
Release 7.3 (Revision 1.0)
283
Содержание RELEASE 7.3
Страница 14: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 14...
Страница 195: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 195...
Страница 210: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 210...
Страница 214: ...7 2 2 PVL Drive Information Window HPSS Management Guide November 2009 Release 7 3 Revision 1 0 214...
Страница 215: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 215...
Страница 222: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 222...
Страница 266: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 266...
Страница 293: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 293...
Страница 367: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 367...
Страница 372: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 372...
Страница 384: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 384...
Страница 388: ...HPSS Management Guide November 2009 Release 7 3 Revision 1 0 388...