2.
Determine where to place the system unit in the rack. As you plan for installing the system unit in a
rack, consider the following information:
v
Organize larger and heavier units into the lower part of the rack.
v
Plan to install units into the lower part of the rack first.
v
Record the Electronic Industries Alliance (EIA) locations in your plan.
3.
If necessary, remove the filler panels to allow access to the inside of the rack enclosure where you
plan to place the unit, as shown in Figure 1.
4.
Determine to place the system in the rack. Record the EIA location.
5.
Facing the front of the rack and working from the right side, use tape, a marker, or pencil to mark
the lower hole of each EIA unit.
6.
Repeat step 5 for the corresponding holes located on the left side of the rack.
7.
Go to the rear of the rack.
8.
On the right side, find the EIA unit that corresponds to the bottom EIA unit marked on the front of
the rack.
Figure 1. Removing the filler panels
2
Installing the 7063-CR1 into a rack