• Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top

of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them

to stabilize your body position (for example, when working from a ladder).

• Stability hazard:

– The rack may tip over causing serious personal injury.
– Before extending the rack to the installation position, read the installation instructions.
– Do not put any load on the slide-rail mounted equipment mounted in the installation position.
– Do not leave the slide-rail mounted equipment in the installation position.

• Each rack cabinet might have more than one power cord.

– For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed

to disconnect power during servicing.

– For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls

the power to the system unit(s), or disconnect the customer’s DC power source, when

directed to disconnect power during servicing.

• Connect all devices installed in a rack cabinet to power devices installed in the same rack

cabinet. Do not plug a power cord from a device installed in one rack cabinet into a power device

installed in a different rack cabinet.

• An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts

of the system or the devices that attach to the system. It is the responsibility of the customer to

ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (R001 part

1 of 2)

(R001 part 2 of 2):

CAUTION:
• Do not install a unit in a rack where the internal rack ambient temperatures will exceed the

manufacturer's recommended ambient temperature for all your rack-mounted devices.

• Do not install a unit in a rack where the air flow is compromised. Ensure that air flow is not

blocked or reduced on any side, front, or back of a unit used for air flow through the unit.

• Consideration should be given to the connection of the equipment to the supply circuit so that

overloading of the circuits does not compromise the supply wiring or overcurrent protection. To

provide the correct power connection to a rack, refer to the rating labels located on the

equipment in the rack to determine the total power requirement of the supply circuit.

• (For sliding drawers.) Do not pull out or install any drawer or feature if the rack stabilizer

brackets are not attached to the rack or if the rack is not bolted to the floor. Do not pull out more

than one drawer at a time. The rack might become unstable if you pull out more than one drawer

at a time.

• (For fixed drawers.) This drawer is a fixed drawer and must not be moved for servicing unless

specified by the manufacturer. Attempting to move the drawer partially or completely out of the

rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001

part 2 of 2)

Safety notices  vii

Содержание Power System IC922

Страница 1: ...Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X IBM...

Страница 2: ...ual G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER9 processor and to all associated models Copyright Inte...

Страница 3: ...ent rules and slot priorities for the 9183 22X system 30 PCIe adapters by feature code 33 Installing a PCIe adapter 81 Common procedures for servicing or installing features 89 Before you begin 89 Ide...

Страница 4: ...iv...

Страница 5: ...1 800 300 8751 German safety information Das Produkt ist nicht f r den Einsatz an Bildschirmarbeitspl tzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Laser safety information IBM servers can...

Страница 6: ...verything unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PDP and rem...

Страница 7: ...devices that attach to the system It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 R001 part 2 of 2 CA...

Страница 8: ...hat you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings are...

Страница 9: ...position for example when working from a ladder Stability hazard The rack may tip over causing serious personal injury Before extending the rack to the installation position read the installation ins...

Страница 10: ...ultiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 x Power Systems Installing t...

Страница 11: ...ing into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of opt...

Страница 12: ...out appreciable force so take care not to push or lean Keep riser tilt adjustable angling platform option flat at all times except for final minor angle adjustment when needed Do not stand under overh...

Страница 13: ...itable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outsid...

Страница 14: ...xiv Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 15: ...tions Center http www 05 ibm com e business linkweb publications servlet pbi wss This bulletin provides a list of the key IBM system installation activities and a list of activities that might be bill...

Страница 16: ...all the system unit into the rack Procedure 1 Read the Rack safety notices http www ibm com support knowledgecenter POWER9 p9hbf p9hbf_racksafety htm 2 Determine where to place the system unit in the...

Страница 17: ...h that the mark can also be seen from the rear of the rack 5 Mark the corresponding hole on the left side of the rack 6 Go to the rear of the rack 7 On the right side find the EIA unit that correspond...

Страница 18: ...e components relate to each other Procedure 1 At the front of the rack align the pins on end of the left rail 1 with the rear of the rack Figure 2 Aligning the end of the left rail to the rear of the...

Страница 19: ...ail retention bracket out 1 and pull the front of the rail toward the front of the rack until the pins are aligned with the correct holes in the rack 2 Swivel the rail retention bracket so that it loc...

Страница 20: ...rd until they click twice into place 3 Carefully lift the server and tilt it into position over the slide rails so that the rear nail heads on the server line up with the rear slots on the slide rails...

Страница 21: ...ng parts Item Description A Inner cable management arm tab B Inner mounting bracket C Outer cable management arm tab D Outer mounting bracket E CMA latch F Outer cable management arm tab Figure 5 Rela...

Страница 22: ...present remove and discard any plug that covers the ports on the rear of the system The port covers ensure that you are reminded that you must reset the Administrator password on your managed system u...

Страница 23: ...r Description 1 Video Graphics Array VGA Note Cables up to 3 meters are supported 2 Serial Note Cables up to 3 meters are supported 3 Dedicated BMC Ethernet Use this port for the BMC IPMI interface et...

Страница 24: ...e rack rear door will close To install the cable management arm on a 7014 T42 or 9363 RC4 rack complete the following steps a Insert the inner cable management arm tab A to the inner mounting bracket...

Страница 25: ...t on the front of the system has the same restriction g Route the cables through the cable management arm h At each point where you removed the cable management arm baskets attach a hook and loop clos...

Страница 26: ...systems the operating system runs directly on the Open Power Abstraction Layer OPAL firmware For more information about installing the Linux operating system on bare metal systems see Installing Linu...

Страница 27: ...rrect missing or damaged parts consult any of the following resources Your IBM reseller IBM Rochester manufacturing automated information line at 1 800 300 8751 United States only The Directory of wor...

Страница 28: ...stem service management monitoring maintenance and control For more information see Managing OpenBMC based systems http www ibm com support knowledgecenter POWER9 p9eih p9eih_openbmc_kickoff htm Note...

Страница 29: ...surface until the service procedure is completed and if applicable until the service access cover is replaced Attention Attach an electrostatic discharge ESD wrist strap to the front ESD jack to the...

Страница 30: ...d insert it into the drive slot Important Ensure that the drive is fully seated and is all the way into the system c Lock the drive bay handle A by pushing in the handle release as shown in the follow...

Страница 31: ...m Learn the memory module placement rules for the system The considerations for installing memory modules in the system follow The system supports up to 32 DDR4 RDIMM memory modules The system support...

Страница 32: ...re shows the locations for memory modules in the 9183 22X system Figure 17 Memory module slot locations The following table shows the order in which memory modules must be placed in the 9183 22X syste...

Страница 33: ...nnected to an unpainted metal surface until the service procedure is completed and if applicable until the service access cover is replaced Attention Attach an electrostatic discharge ESD wrist strap...

Страница 34: ...ate the memory module to install The following figure shows the location of memory modules in the system Figure 19 Locating the memory modules 20 Power Systems Installing the System and Ordered Parts...

Страница 35: ...g pin A as shown in the following figure Figure 20 Retracting the retaining pin and removing the left cable holder c Lift the drive cable holder out of the system 5 If the memory socket is covered by...

Страница 36: ...system complete the following steps to remove the power distribution board Removing the power distribution board requires that the power supplies be partially removed from the system a Remove the dri...

Страница 37: ...le holder out of the system d Remove the cables from the top of the power distribution board e To remove the power distribution board unlatch tab A unplug and lift the power distribution board from th...

Страница 38: ...ll the memory module complete the following steps a Push the locking tabs to the open position away from the slot in the direction shown in the following figure 24 Power Systems Installing the System...

Страница 39: ...c Press firmly on each side of the memory module until the locking tab locks in place with an audible click 8 If you removed a PCIe riser replace the PCIe riser by using the following procedure a Move...

Страница 40: ...er by using the following procedure a Replace the drive cable holder in the system Ensure that the alignment pins match the slots in the holder b Reset the retaining pin A to lock the holder in place...

Страница 41: ...place the power distribution board by using the following procedure a Replace the power distribution board by plugging it into the system backplane as shown in the following figure Use the alignment p...

Страница 42: ...tion board a Replace the drive cable holder in the system Ensure that the alignment pins match the slots in the holder b Reset the retaining pin A to lock the holder in place as shown in the following...

Страница 43: ...lace the drive cables into the drive cable holder 11 Replace the air baffle A straight down into the chassis as shown in the following figure Ensure that the pins inside the system side walls align pr...

Страница 44: ...ities for the 9183 22X system Find information about the placement rules and slot priorities for the Peripheral Component Interconnect Express PCIe adapters that are supported for the system PCIe slot...

Страница 45: ...ts double wide adapters CPU 1 Yes 10 PCIe3 x8 Full height Half length CPU 1 No PCIe adapter placement rules Use this information to select slots for installing PCIe adapters in the system Table 7 on p...

Страница 46: ...with 2 mini SAS cables FC EK41 Adapter FRU number 02WG017 5 10 2 EK43 Broadcom HBA 9305 16i PCIe3 X8 with 4 mini SAS cables FC EK43 Adapter FRU number 02WG020 5 1 EK47 EK47 Broadcom MegaRAID 9361 8i S...

Страница 47: ...apter FC EN0S FC EN0T FC EN0U and FC EN0V CCIN 2CC3 Adapter FRU number 00E2715 1 6 2 7 4 EN0U PCIe2 4 port 10 Gb 1 GbE SR RJ45 adapter FC EN0S FC EN0T FC EN0U and FC EN0V CCIN 2CC3 Adapter FRU number...

Страница 48: ...adapter FC EK4L Adapter FRU number 02CM988 EK4M NVIDIA T4 PCIe GPU accelerator adapter FC EK4M Adapter FRU number 02CM978 EL3Z PCIe2 2 port 10 GbE BaseT RJ45 adapter FC EL3Z FC EL55 FC EN0W and FC EN...

Страница 49: ...speed Each of the Ethernet ports can be connected by using CAT5e or later UTP cables for 1000 Mbps network attachment CAT5 or CAT3 UTP cables for 100 Mbps or 10 Mbps network attachment The cables are...

Страница 50: ...Figure 31 FC 5260 and FC EL4M PCIe2 4 port 1 GbE adapter 36 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 51: ...M I O bus architecture PCIe2 x4 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgec...

Страница 52: ...ting system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites...

Страница 53: ...Cu Adapter is a PCI Express PCIe generation 3 Gen3 x8 adapter The adapter provides two 10 Gb SFP ports and supports both the Ethernet network interface controller NIC function and RDMA over Converged...

Страница 54: ...us architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter P...

Страница 55: ...more information about adapter cabling see the Cable and Transceiver information on page 41 Transceivers IBM qualifies and supports SFP optical transceiver FC EB46 to install into the adapter Customer...

Страница 56: ...ms support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website...

Страница 57: ...Figure 35 PCIe3 LP 2 port 25 10 Gb NIC RoCE SFP28 Adapter FC EC2T Installing and configuring the 9183 22X 43...

Страница 58: ...bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter...

Страница 59: ...end of these cables For more information about adapter cabling see Cable and Transceiver information on page 45 Transceivers For 25 GbE IBM qualifies and supports SFP28 optical transceiver FC EB47 to...

Страница 60: ...split cable EN01 10 Gb s 1 m 3 3 ft copper active twinax Ethernet cable EN02 10 Gb s 3 m 9 8 ft copper active twinax Ethernet cable EN03 10 Gb s 5 m 16 4 ft copper active twinax Ethernet cable EN03 10...

Страница 61: ...a low profile adapter and FC EC63 is a full height adapter The PCIe4 x16 1 Port enhanced data rate EDR 100 GB Infiniband IB ConnectX 5 CAPI Capable Adapter is a PCI Express PCIe generation 4 Gen4 x16...

Страница 62: ...4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_m...

Страница 63: ...omercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter...

Страница 64: ...4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_m...

Страница 65: ...SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can...

Страница 66: ...Figure 39 2 port 100 GbE RoCE En Connectx 5 Gen4 PCIe x16 adapter FC EC66 52 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 67: ...p9eab_mtm_pciplacement htm and select the system you are working on Cables For 100G IBM offers either Direct Attach Copper DAC cables up to 2 M or Active Optical Cables AOC up to 100 M QSFP28 based tr...

Страница 68: ...ansceiver matrix Feature Description EB59 100Gbase SR4 optical transceiver MTP MPO cable purchased separately FC EB2J 10 M FC EB2K 30 M EB5J QSFP28 Passive Copper 100 Gb Ethernet Cable 5 M EB5K QSFP28...

Страница 69: ...ng devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central h...

Страница 70: ...ion and Downloads Specifications Item Description Adapter FRU number 02WG017 I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adap...

Страница 71: ...ion of enabling libraries firmware and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare ipr...

Страница 72: ...tion and Downloads Specifications Item Description Adapter FRU number 02WG020 I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe ada...

Страница 73: ...ebsite http www14 software ibm com webapp set2 sas f lopdiags info LinuxAlerts html EK47 Broadcom MegaRAID 9361 8i SAS3 X8 2 GB cache controller and CacheVault Power Module with 2 mini SAS cables FC E...

Страница 74: ...Figure 43 Broadcom 9361 8i SAS3 X8 adapter 60 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 75: ...Power Module For more information about the Broadcom MegaRAID 9361 8i SAS3 X8 adapter refer to the Broadcom website https www broadcom com products storage raid controllers megaraid sas 9361 8i Use th...

Страница 76: ...latest version of enabling libraries firmware and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support custo...

Страница 77: ...Figure 45 FC EK4L low profile NVIDIA T4 PCIe GPU accelerator adapter Installing and configuring the 9183 22X 63...

Страница 78: ...n about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select th...

Страница 79: ...ration 3 gen3 PCIe adapter This adapter is a high performance x8 short form adapter also referred to as a PCIe Host Bus Adapter HBA The adapter provides two ports of 16 Gb Fibre Channel capability usi...

Страница 80: ...e virtualization capabilities with support for N_Port ID Virtualization NPIV and virtual fabric VF Provides support for message signaled interrupts extended MSI X Provides support for 255 VFs and 1024...

Страница 81: ...Figure 47 PCIe3 16 Gb 2 port Fibre Channel adapter FC EL43 and EN0B Installing and configuring the 9183 22X 67...

Страница 82: ...hitecture PCIe base and CEM 3 0 x8 PCIe bus interface Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm...

Страница 83: ...6 71 ft 0 5 400 m 1 64 1312 34 ft 8 Gbps 0 5 21 m 1 64 68 89 ft 0 5 50 m 1 64 164 04 ft 0 5 150 m 1 64 492 12 ft 0 5 190 m 1 64 623 36 ft 16 Gbps 0 5 15 m 1 64 49 21 ft 0 5 35 m 1 64 114 82 ft 0 5 100...

Страница 84: ...ave the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system...

Страница 85: ...t connectivity with a nominal data rate of 10 Gbps gigabits per second Figure 49 on page 72 shows the FC EN0S and FC EN0U adapter Figure 50 on page 73 shows the FC EN0T and FC EN0V adapter Each of the...

Страница 86: ...DP TCP segmentation Offload TSO for IPv4 and IPv6 Supports TCP segmentation or large send offload Supports EEPROM SPI and single EEPROM Figure 49 PCIe2 4 Port 10 Gb 1 GbE SR Copper SFP RJ45 adapter FC...

Страница 87: ...fications Item Description Adapter FRU number 00E2715 Regular height tailstock part number 00E2863 Low profile tailstock part number 00E2720 Wrap plug FRU number 12R9314 SFP SR wrap plug 10N7405 1 Gb...

Страница 88: ...108 26 feet 0 5 meters to 82 meters 1 64 feet to 269 02 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet Operating system or partition requirements If you are installing a new feature ensure th...

Страница 89: ...network convergence adapter The 10 Gb RJ45 ports can function in the NIC mode The adapter can be used as the host local area network LAN adapter The adapter supports interrupt moderation to deliver i...

Страница 90: ...port 10 GbE BaseT RJ45 adapter FC EL55 or FC EN0W Figure 52 PCIe2 LP 2 port 10 GbE BaseT RJ45 adapter FC EL3Z or FC EN0X 76 Power Systems Installing the System and Ordered Parts for the IBM Power Syst...

Страница 91: ...opics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support cust...

Страница 92: ...and use shortwave laser optics The adapter operates at link speeds of 4 8 16 and 32 Gbps and automatically negotiates to the highest speed possible Each port has two LED indicators that are on the bra...

Страница 93: ...ling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC Syst...

Страница 94: ...next to each connector These LEDs communicate boot status and give a visual indication of the operating state The LEDs have five defined state solid on solid off slow blink fast blink and flashing The...

Страница 95: ...see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 so...

Страница 96: ...D jack to the rear ESD jack or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware When you use an ESD wrist strap follow all electrical s...

Страница 97: ...gged into the system backplane continue with step 4 on page 83 If the PCIe adapter is plugged into a PCIe riser continue with step 7 on page 85 4 Remove the PCIe slot cover from the system backplane b...

Страница 98: ...f the PCIe adapter 6 Insert the PCIe adapter aligning it properly and inserting it fully into the slot as shown in the following figure Replace the tailstock screw to secure the PCIe adapter to the sy...

Страница 99: ...pter Continue with step 8 on page 88 7 To insert a PCIe adapter into a PCIe riser complete the following steps a Lift the PCIe riser up out of the system as shown in the following figure Installing an...

Страница 100: ...Ie riser b Removing the tailstock screw and remove the PCIe tailstock filler A from the riser B as shown in the following figure 86 Power Systems Installing the System and Ordered Parts for the IBM Po...

Страница 101: ...the PCIe adapter A into the proper slot in the PCIe riser B as shown in the following figure Replace the tailstock screw to secure the PCIe adapter to the PCIe riser Figure 60 Inserting a PCIe adapte...

Страница 102: ...re 61 Inserting the PCIe adapter riser 8 Replace any plugs that you removed from the PCIe adapter Insert the cables into the PCIe adapter 9 Replace the air baffle A straight down into the chassis as s...

Страница 103: ...stalling removing and replacing features in the system Before you begin Observe these precautions when you are installing removing or replacing features and parts in the IBM Power System IC922 9183 22...

Страница 104: ...erly wired outlets When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Do not attempt to switch...

Страница 105: ...n read the installation instructions Do not put any load on the slide rail mounted equipment mounted in the installation position Do not leave the slide rail mounted equipment in the installation posi...

Страница 106: ...e if the rack stabilizer brackets are not attached to the rack or if the rack is not bolted to the floor Do not pull out more than one drawer at a time The rack might become unstable if you pull out m...

Страница 107: ...wer cables To remove all hazardous voltages disconnect all power cords and power cables L003 L005 CAUTION Hazardous energy present Voltages with hazardous energy might cause heating when shorted with...

Страница 108: ...m planetwide 7 If you encounter difficulties during the installation contact your service provider your IBM reseller or your next level of support 8 Ensure that the top cover is on when the system is...

Страница 109: ...Figure 63 Front control panel LEDs Figure 64 Front drive LEDs Figure 65 Rear LEDs Installing and configuring the 9183 22X 95...

Страница 110: ...cing Procedure You can activate the blue system identify LED by pressing the Identify LED button on the control panel for at least half a second Figure 67 Locating the Identify LED button You can use...

Страница 111: ...arge ESD wrist strap to the front ESD jack to the rear ESD jack or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware When you use an ESD...

Страница 112: ...or or or 98 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 113: ...ult in splattered metal burns or both L005 6 If the power distribution board needs to be removed if the system backplane needs to be removed or if DIMM 0 needs to be installed removed or replaced part...

Страница 114: ...e Placing a 9183 22X system into the service position on page 109 CAUTION Do not place any object on top of a rack mounted device unless that rack mounted device is intended for use as a shelf R008 L0...

Страница 115: ...ave the electrostatic discharge ESD wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface If not do so now 2 Replace the service access cover Fo...

Страница 116: ...r replaced a PCIe adapter update the adapter firmware See Getting firmware fixes for vendor I O adapters from the vendor website www ibm com support knowledgecenter POWER9 p9ei8 p9ei8_update_other_ada...

Страница 117: ...er to the unit 2 Press the power on switch that is shown in the following figure Note It might take several minutes for the power on LED to begin flashing Do not continue to press the power on switch...

Страница 118: ...for the system StorCLI commands available at the operating system Learn about the StorCLI commands that are available at the operating system To show a summary of the drive and controller status stor...

Страница 119: ...ff default pi DimmerSwitch ds default automatic auto none maximum max MaximumWithoutCaching maxnocache WT WB AWB nora ra direct cached cachevd Strip 8 16 32 64 128 256 512 1024 AfterVd X EmulationType...

Страница 120: ...ou want to replace use the command nvme list If you are searching for a failed drive you can check each drive using the command nvme smart log device To turn on the identify LED use the command dd if...

Страница 121: ...he 9183 22X system Find information about removing and replacing covers for the IBM Power System IC922 9183 22X system Removing the service access cover from a 9183 22X system To remove the service ac...

Страница 122: ...performance the service access cover must be installed and fully seated before you power on the system Procedure 1 Place the cover A on the system unit such that the alignment pins on the cover are al...

Страница 123: ...erating position Placing a 9183 22X system into the service position To place a system into the service position complete the steps in this procedure Before you begin Notes When you place the system i...

Страница 124: ...following figure Figure 74 Placing the system into the service position 3 Grasp the EIA holders at B and C above the latches do not pull the system by using the latches to pull the system out of the...

Страница 125: ...m Find information about removing and replacing power cords in the IBM Power System IC922 9183 22X server Disconnecting power cords from the 9183 22X system To disconnect a power cord complete the ste...

Страница 126: ...n the following figure Note This system might be equipped with two or more power supplies If the removing and replacing procedures require the power to be off then ensure that all the power sources to...

Страница 127: ...system To connect a power cord complete the steps in this procedure Procedure 1 Open the rear rack door on the system unit that you are servicing 2 Using your labels reconnect the power cords to the...

Страница 128: ...sure to maintain at least a 5 cm 2 in diameter loop Use the hook and loop fastener to tie the power cord to the power supply handle Figure 79 Routing the power cord loop in the cable management arm 4...

Страница 129: ...static discharge from damaging your hardware When you use an ESD wrist strap follow all electrical safety procedures An ESD wrist strap is used for static control It does not increase or decrease your...

Страница 130: ...or or or 116 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 131: ...splattered metal burns or both L005 3 Remove the power supplies from the system as shown in the following figure a To release a power supply from its position in the system pull the locking tab A to t...

Страница 132: ...ound jack or connected to an unpainted metal surface If not do so now 2 Replace the power supplies as shown in the following figure a Place your other hand underneath the power supply b Align the powe...

Страница 133: ...re 81 Replacing the power supplies in the system 3 Reconnect the power cords to the power supplies For instructions see Connecting power cords to the 9183 22X system on page 113 Additional procedures...

Страница 134: ...120 Power Systems Installing the System and Ordered Parts for the IBM Power System IC922 9183 22X...

Страница 135: ...duct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner s...

Страница 136: ...ology content successfully Overview The IBM Power Systems servers include the following major accessibility features Keyboard only operation Operations that use a screen reader The IBM Power Systems s...

Страница 137: ...rovide you as the customer the ability to collect personally identifiable information from end users via cookies and other technologies you should seek your own legal advice about any laws applicable...

Страница 138: ...linie 2014 30 EU zur Angleichung der Rechtsvorschriften ber die elektromagnetische Vertr glichkeit in den EU Mitgliedsstaatenund h lt die Grenzwerte der EN 55022 EN 55032 Klasse A ein Um dieses sicher...

Страница 139: ...elle Informationen Das Ger t erf llt die Schutzanforderungen nach EN 55024 und EN 55022 EN 55032 Klasse A Japan Electronics and Information Technology Industries Association JEITA Notice This statemen...

Страница 140: ...energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cau...

Страница 141: ...luding the fitting of non IBM option cards German Notice Deutschsprachiger EU Hinweis Hinweis f r Ger te der Klasse B EU Richtlinie zur Elektromagnetischen Vertr glichkeit Dieses Produkt entspricht de...

Страница 142: ...en nach EN 55024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This sta...

Страница 143: ...or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void...

Страница 144: ...e above instructions are not being properly followed You may not download export or re export this information except in full compliance with all applicable laws and regulations including all United S...

Страница 145: ......

Страница 146: ...IBM...

Отзывы: