b. Disable any additional adapters other than the Local Area Connection.
c. Right click the adapter and select Properties.
d. Click Internet Protocol Version 4 (TCP/IPv4) and select Properties.
Note: If you are returning the device to the network after you set up the Operations Console, record
the IP information that is displayed.
e. Select Obtain an IP address automatically. This ensures that the PC receives an IP address in the
169.254.x.x range.
4. To disable the PC firewall, complete the following steps.
Note: All PC firewalls must be disabled for the initial connection.
a. In the Windows control panel, click Firewall settings and disable the firewall.
b. In the Windows control panel, click Security center. Check for a firewall and, if present, disable it.
c. Scan all tasks that are running on the PC for any other software firewalls and disable the firewall.
5. Power on the server by completing the following steps:
a. Set the manual initial program load (IPL) by completing the following steps:
i) Locate the server's control panel.
ii) Press the Up arrow key until you see 02, and press Enter.
iii) Press Enter again. A < (less than symbol) appears next to N.
iv) Press the Up Arrow key. The N changes to an M.
v) Press Enter.
vi) Press Enter twice. A 02 is displayed on the control panel.
b. After you have the server set to a manual IPL, push the white power button to power on the server.
Note: During the IPL, the system displays C6004031 on the control panel, which indicates that the
system is searching for an Operations Console. The system might take 20 - 30 minutes to complete
this action. If A6005008 is displayed on the control panel, this means that no Operations Console
is available. This might indicate that the system is not preinstalled with IBM i and you must set the
console type to LAN.
6. Perform this step if the system is not preinstalled with IBM i. For setting the console type to LAN,
complete the following steps:
a. Enable the control panel functions by completing the following steps:
i) Select function 25 on the control panel and press Enter. The return code must be 00.
ii) Select function 26 on the control panel and press Enter.
Note: If you see a FF return code, go back to function 25 and press Enter, then return to function
26 and press Enter.
b. Check your current setting(s). Use console service functions (65+21+11) to check the current
setting.
• A600 500A = No console defined
• A603 500A = LAN console
• A604 500A = HMC console
If the system reference code (SRC) = A603500A, skip to step “7” on page 8. For all others SRCs,
continue with the next step.
c. Set console type to LAN.
For release 7.4 and earlier, complete the following steps.
i) Use the 65+21+11 sequences until it returns A603500B. This indicates that the console type
will be changed to LAN.
Installing the IBM Power S1014 (9105-41B) 7