v
Yes:
Go to step 30.
v
No:
Continue with the next step.
23.
Does the list of all partitions you recorded in step 11 on page 82 contain more than one entry?
v
Yes:
Continue with the next step.
v
No:
Go to step 30.
24.
Is the error class recorded in step 23?
v
Yes:
Continue with the next step.
v
No:
Go to step 30.
25.
Perform all the following steps for each entry in the list of all partitions you recorded in step 11 on
page 82, except for the partition you were using to debug the original problem.
26.
From the list of all partitions, open the IVM virtual terminal window of a partition, and then type
diag
at the AIX command prompt.
27.
When the diagnostic operating instructions are displayed, complete the following steps:
1.
Press Enter.
2.
Select the Task Selection option.
3.
Select the Log Repair option.
4.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the resource associated with that repair action.
v
If the resource associated with your repair action is not displayed on the Resource List, select sysplanar0.
5.
Click Commit after you make your selection.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
28.
Exit from diagnostics in this partition and return to the AIX command prompt.
29.
Have all the partitions in the list of all partitions you recorded in step 11 on page 82 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 25 to process the next partition in the list you recorded in step 11 on page 82.
30.
Have all the serviceable events recorded in step 4 on page 82 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 5 on page 82 and process the next service action event in the list of serviceable events recorded in
31.
While processing all service action events, were you directed to step 14 on page 83?
84
Power Systems: System backplane for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
Содержание Power 730 Express 8231-E2B
Страница 1: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 2: ......
Страница 3: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 14: ...2 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 44: ...32 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 110: ...98 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 111: ......
Страница 112: ...IBM Printed in USA...