If the system-level diagnostics tests...
Then...
Resulted in some test failures
Determine the cause of the problem.
1.
Exit Maintenance mode by entering the
following command:
halt
2.
Perform a clean shutdown and
disconnect the power supplies.
3.
Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4.
Reconnect the power supplies and power
on the storage system.
5.
Rerun the system-level diagnostics tests.
Resetting the date and time on the system
After you reconnect the battery and reboot Data ONTAP, you must reset the date
and time on the system.
Procedure
1.
Display the current date on the node or nodes by entering the following
command:
For...
Issue the command...
7-Mode
date
Note:
If your system is in an HA pair ,
make sure that you display the date and
time on the partner node and set the target
node to those values.
Clustered Data ONTAP
system date show
Note:
Make sure that you display the date
and time on the other nodes in the cluster
and set the target node to those values.
2.
Set the date by entering the following command:
Replacing N6200 series system devices
101
Содержание N6270
Страница 12: ...xii IBM System Storage N6200 Series Hardware and Service Guide...
Страница 16: ...xvi IBM System Storage N6200 Series Hardware and Service Guide...
Страница 18: ...xviii IBM System Storage N6200 Series Hardware and Service Guide...
Страница 20: ...xx IBM System Storage N6200 Series Hardware and Service Guide...
Страница 46: ...20 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 130: ...104 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 134: ...108 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 146: ...120 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 147: ......
Страница 148: ...Printed in USA GA32 0838 04...