background image

3. Unscrew and remove the quantity-4 rail kit rear-mounting bracket screws to adjust the rack post-to-

post distance for the left rail subassembly.

4. Relocate the left rail mounting bracket to approximately match the rack post-to-post distance

recorded in Step 1, above.

This bracket has one inch of available adjustment after the screws are secured. After torquing the

quantity-4 screws removed in Step 3, verify that the bracket can be adjusted to the exact rack post-

to-post distance determined in Step 1. Torque to 1.36 N-m (12 lbf-in)

5. Repeat Step 1 through Step 4 for the right outer rail subassembly.

Chapter 4. Installation  31

Содержание Medium J11

Страница 1: ...IBM Cloud Object Storage System Version 3 14 13 Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual 4957 J11 4958 J11 4957 J12 4958 J12 IBM...

Страница 2: ...The information in the IBM Environmental Notices and User Guide provided on a DVD This edition applies to IBM Cloud Object Storage System Slicestor J11 J12 and is valid until replaced by new editions...

Страница 3: ...y 4 Rack system safety precautions 4 Chapter 3 System overview 5 Enclosure chassis 5 Enclosure configuration 5 Enclosure variants 6 Enclosure core product 7 Enclosure front panel 7 Enclosure rear pane...

Страница 4: ...s 55 Replacing a PSU module 56 Removing a PSU module 56 Installing a PSU module 58 Replacing a system fan module 58 Removing a system fan module 58 Installing a system fan module 59 Replacing a contro...

Страница 5: ...J11 disk slots highlighted 12 12 The following highlights illustrate the slots to be populated in order from left to right as disks are added for the four configurations noted in the above table 13 1...

Страница 6: ...Removing a controller fan 2 of 2 61 33 Removing an HS Expander 1 of 2 62 34 Removing an HS Expander 2 of 2 63 35 Removing a disk drive module 1 of 2 64 36 Removing a disk drive module 2 of 2 64 37 Dri...

Страница 7: ...rear panel 17 9 LEDs system fan module rear panel 18 10 LEDs Expansion module rear panel 20 11 LED Dual path LFF disk drive carrier modules top panel 22 12 LEDs Controller channel fan module top panel...

Страница 8: ...24 4U enclosure dimensions 71 25 Disk Enclosure weights 71 26 Ambient temperature and humidity 71 27 Power cooling module specifications 72 28 Unpacking the enclosure 3 piece box with packing 77 viii...

Страница 9: ...nd disk drives prior to attempting this installation Only personnel proficient in working with computer hardware and disk drives should attempt to install this appliance enclosure After all appliances...

Страница 10: ...x IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 11: ...open or service any power supply assembly Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm The product might be...

Страница 12: ...e system Use care when handling equipment to avoid cuts scrapes and pinching D005 DANGER If the receptacle has a metal shell do not touch the shell until you have completed the voltage and grounding c...

Страница 13: ...ide front or back of a unit used for air flow through the unit Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does not compr...

Страница 14: ...ery information flat panel display refrigeration and water cooling systems external power supplies and safety data sheets Electromagnetic Compatibility Notices Class A Notices The following Class A st...

Страница 15: ...European Community and Morocco Notice Germany Notice Safety and environmental notices xv...

Страница 16: ...ciation JEITA Notice Japan Voluntary Control Council for Interference VCCI Notice Korea Notice People s Republic of China Notice Russia Notice xvi IBM Cloud Object Storage System Medium Large J11 J12...

Страница 17: ...1 5 Product description Models A10 C10 M10 J10 J11 J12 Declared A weighted sound power level LWA m B Declared A Weighted Sound Pressure Level LpA m dB Statistical adder for verification Kv B Operatin...

Страница 18: ...um of LWA m and Kv 4 All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296 5 B dB abbreviations for bels and decibels respectively 1 B 10 dB 6 Notice Government...

Страница 19: ...mation Technical support contacts For more information on the product or help with troubleshooting contact IBM Support at ibm com mysupport or visit the Directory of worldwide contacts Copyright IBM C...

Страница 20: ...xx IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 21: ...cautions must be followed to protect yourself and the appliance Do not work alone with high voltage components Be aware of the locations of the power switch on the appliance and the room s emergency p...

Страница 22: ...lent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present 2 IBM Cloud Object Storage System Medium Large J...

Страница 23: ...le slots See Figure 9 on page 11 for removable lids see Figure 10 on page 11 and Figure 11 on page 12 for disk slots and CRU module slot indexing Belt straps and optional lift handles are designed to...

Страница 24: ...Do not remove covers from the PSU or any other CRU module There is a danger of electric shock inside Return the plug in module to your supplier for repair Important The RJ 45 socket on IOMs is not cur...

Страница 25: ...isk drive base planes Four 24 hard disk drive base plane boards support 96 disk drive connections in the drive channel A ten hard disk drive base plane board supports 10 disk drive connections in the...

Страница 26: ...ariants Medium and Large Disk Enclosure variants are described The IBM COS Medium and Large Disk Enclosure is configured as an expansion enclosure as shown in the table below The enclosure supports 10...

Страница 27: ...nit modules Fan module system four system fan modules for enclosure cooling Two interface slots one of which holds an IOM with four mini SAS hard disk SFF 8644 ports and a serial port The other slot c...

Страница 28: ...enclosure forward for in rack servicing tasks Enclosure rear panel The Disk Enclosure rear panel components are described Concept The following enclosure rear panel diagram intentionally omits the lif...

Страница 29: ...howing module slot indexing as viewed from the rear panel Figure 5 IBM COS Medium and Large Disk Enclosure rear panel module slot index diagram Expansion module The following figure shows the expansio...

Страница 30: ...e 8 System fan module detail Enclosure top panel The Disk Enclosure top panel is described Overview The following figure shows a top view of the Disk Enclosure with simplified covers The figure is ori...

Страница 31: ...ules and limited access to IOMs C Fixed cover does not remove It provides protection for the IOMs Figure 10 Top panel with covers not shown The following figure provides a conceptual diagram of module...

Страница 32: ...lated Medium Disk Enclosure J11 disk drive slots The IBM COS Medium J11 Disk Enclosure provides support for up to 53 disk drive modules It can be partially populated to allow use with fewer than 53 di...

Страница 33: ...ted with new disks to avoid the need to resize the pool multiple times For more information see the Resizing a storage pool section in the Manager Administration Guide Partially populated Large Disk E...

Страница 34: ...y present the user with an option to resize the storage pool to take advantage of the additional capacity To make this resize operation more efficient this should not be done until all disk enclosures...

Страница 35: ...installed in the rack This LED is normally off and illuminates only during the identification process Drive activity LED green The LED illuminates blinking green to indicate disk drive activity If the...

Страница 36: ...riencing a system hardware fault with a component accessible via the enclosure top panel Amber display indicates that the top lid on the left should be removed to locate the faulty component within th...

Страница 37: ...eplacement must be completed as soon as possible after the removal of the defective PSU to avoid a thermal exception The replacement procedure should be completed within an absolute maximum of three m...

Страница 38: ...take a few seconds Replacement must be completed as soon as possible after the removal of the defective system fan to avoid a thermal exception The replacement procedure should be completed within an...

Страница 39: ...e versa within the enclosure An enclosure system fault occurs when incompatible configurations are detected The replacement procedure should be completed within an absolute maximum of three minutes Im...

Страница 40: ...A fault has been detected or a service action is required 4 Power OK Green The expansion module is operating normally Blinking green System is booting Off The expansion module is powered off 5 Etherne...

Страница 41: ...tch tab on left and disk PCB facing up Revolve the module 90 about the horizontal axis latch is facing up module is standing on end Revolve the module 90 about the vertical axis latch is facing up dis...

Страница 42: ...t LFF disk LED behavior see the Disk drive carrier module LED on page 48 section Controller channel fan module The controller channel fan module supplements the system fans by circulating airflow with...

Страница 43: ...ander module top panel Table 13 HS expander module LEDs Module LED LED behavior states HS Expander Status LED Expander OK Off Expander fault ID amber blinking amber Power off Off Enclosure management...

Страница 44: ...24 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 45: ...utions on page 55 4 Install the Disk Enclosure into the rack space See Installing the Disk Enclosure on page 30 5 Cable the Disk Enclosure to IBM COS Medium and Large Disk Enclosures See Routing cable...

Страница 46: ...y that the site where you will install your storage system has the following A mechanical lift that can safely hoist a 280 lb high density enclosure for installation into a 1 2 m rack A proper redunda...

Страница 47: ...ect that damage has happened photograph the package before opening for possible future reference Retain original packaging materials for use with returns 2 The unpacking sequence pertaining to 4U encl...

Страница 48: ...lated from the remainder of the packaging As a visual aid for this unpacking task see Chapter 9 Enclosure packaging on page 75 for more information about the packaging materials The illustration shows...

Страница 49: ...For rackmount installation do not install the disk drive modules until after the enclosure is mounted in the rack Required tools 2 Phillips screwdriver Requirements for rackmount installation You can...

Страница 50: ...k The cable management arm CMA comprises sub assemblies that attach to the Disk Enclosure rails and rack Warning Do not attempt to install the enclosure into the rack with disks preloaded into drive s...

Страница 51: ...e rack post to post distance recorded in Step 1 above This bracket has one inch of available adjustment after the screws are secured After torquing the quantity 4 screws removed in Step 3 verify that...

Страница 52: ...ps from left to right 8 Insert the right rail subassembly into the rack Attach the adjustable rear mounting bracket to the rail first ensuring that the rail subassembly occupies the lower 2U portion o...

Страница 53: ...sure that the quantity 2 all in one rail kit mounting hardware fully seats into the rack post mounting hole 10 Secure the front and back rail kit mounting brackets with the three 10 32 panhead screws...

Страница 54: ...safe handling precautions ensure the middle slide ball bearing track is fully seated to the front of the middle slide This step is critical for proper rail sequencing and full engagement of the inner...

Страница 55: ...Lower the lift only after the service position is reached and the rail is locked in place Lower the lift by no more than 2 3 while the chassis is inserted from the service position into the rack The i...

Страница 56: ...ess both to disengage the service protection lock Continue depressing springs while inserting the chassis far enough to bypass the locks on both sides 20 Continue inserting the chassis all the way int...

Страница 57: ...the B mark on the CMA arm is pointed upward The B bracket should reside outside of the CMA ramp lip see middle photo 24 Clip the CMA A bracket onto the chassis CMA attachment bracket from Step 22 Ens...

Страница 58: ...escribes the routing of cables through the CMA including using the CMA baskets and the CMA storage shelf located at the rear of the enclosure Procedure 1 Install the data cables and route them through...

Страница 59: ...in the C bracket to allow the inner cable capture arm to seat properly The CMA bracket may need to be shifted slightly in order for the thumbscrew to find the PEM thread in the CMA shelf Secure the th...

Страница 60: ...connectors into the PSUs c Route the cables as shown ensuring they lay flat on the CMA shelf and through the PSU cable clip assembly d Reinstall the M3 panhead screw from Step 3a while torquing the s...

Страница 61: ...b Use all available space on the CMA shelf to make the first 180 bend into the first CMA basket c Keep pairs of dual SAS cables parallel and close together d After all cables including PSU cables are...

Страница 62: ...ections before you remove the PSU from the enclosure Whether standard single lead or bifurcated Y lead power cords must only be connected to a supply range of 200 240V AC as indicated on each PSU s ha...

Страница 63: ...Enclosure must be powered off before attaching the first of the two supplied Mini SAS HD cables Make the first cable connection between the far left port on the HBA as shown in the figure and the top...

Страница 64: ...44 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 65: ...n powering up make sure to power up the enclosures and associated data host in the following order Expansion enclosures first This ensures that the disks in the drive enclosure have enough time to com...

Страница 66: ...umber Software SES The enclosure UID number can be read and set through the management interfaces and SES 46 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation a...

Страница 67: ...ystem Contact IBM support for replacements if Power cables are missing or damaged Plugs are incorrect Power cables are too short Controller Node does not recognize the enclosure system 1 Verify that t...

Страница 68: ...re individually described in the narrative subsections that follow the table Disk drive carrier module LED Disk drive status is monitored by an amber LED mounted on the front of each drive carrier mod...

Страница 69: ...s powered on Check for logs pertaining to the failure If the Fault LED is on a fault condition is detected Re seat the IOM in its slot Check for logs pertaining to the failure If the above actions do...

Страница 70: ...he enclosure will take action such as shutting down in order to protect the enclosure s data content Alarm messages are signaled by the SES pages see Enclosure management on page 23 4 An IOM fault wil...

Страница 71: ...ion of heated air from rear to front Use of the enclosure in a fully enclosed rack is not recommended 4 Verify that all blank modules are in place 5 Reduce the ambient temperature Thermal alarm Table...

Страница 72: ...e front panel illuminates See also Front panel LEDs on page 14 Check the status of the other front panel LEDs Also check the LEDs on the back and top panels must remove a lid of the enclosure to narro...

Страница 73: ...S Medium Large Disk Enclosure support hot plug replacement of redundant expansion modules power supplies fan modules and HS expanders Hot add replacement of expansion enclosures is also supported Firm...

Страница 74: ...ly to other components 2 See Enclosure chassis on page 5 for a description of the chassis CRU 3 See Rackmount rail kit on page 30 and Routing cables using the CMA on page 38 for descriptions of the ra...

Страница 75: ...ntact by transporting and storing products in static safe containers Keep electrostatic sensitive parts in their containers until they arrive at static protected workstations Place parts in a static p...

Страница 76: ...e is in operation Before removing the PSU disconnect the power from the PSU by physically removing the power source in order to ensure your system has warning of imminent power shutdown A faulty PSU m...

Страница 77: ...the figure below Figure 28 Removing a PSU 2 of 2 Note The remove PSU illustrations show a module with a single power connection The procedure applies equally to single cord and dual cord PSU modules...

Страница 78: ...osure rear panel illustrations TIP Replacing a system fan module Procedures for the removal and installation of system fan modules This section provides procedures for replacing a failed system fan mo...

Страница 79: ...See also the detail in the figure below Figure 30 Removing a system fan 2 of 2 Installing a system fan module About this task Refer to Figure 29 on page 59 and Figure 30 on page 59 when performing th...

Страница 80: ...ontroller module fan See Figure 9 on page 11 Reattach top lid B when you complete the procedure If a system fan module fails the remaining fan is sufficient to maintain operation of the enclosure You...

Страница 81: ...arrow since you will insert the module into the slot rather than remove it Important Handle the controller fan carefully and avoid damaging connectors Procedure 1 Check for damage especially to all mo...

Страница 82: ...on page 55 section Tip The illustrations show controller fan module replacement as you face the enclosure front and view the top panel See also Figure 11 on page 12 and Figure 9 on page 11 Removing an...

Страница 83: ...ete the procedure Replacing a drive carrier module Procedures for the removal and installation of a drive carrier module A disk drive module consists of a disk in a carrier or sled Disk Drive in Carri...

Страница 84: ...rive carrier module Procedure 1 Press the latch in the carrier handle towards the handle hinge to release the carrier handle as shown in the figure below Figure 35 Removing a disk drive module 1 of 2...

Страница 85: ...into the enclosure Make sure that the drive carrier is positioned such that the front face of the disk is facing up and the handle opens from the left as you face the enclosure top panel The module sh...

Страница 86: ...enclosure during operation The I O module IOM denotes a controller module You may need to replace an expansion module when The Fault LED is illuminated Logs or events in the firmware indicate a probl...

Страница 87: ...eration See CAUTION bullets regarding electrostatic discharge and anti static protection in the ESD precautions on page 55 section Illustrations in the IOM replacement procedures show rear panel views...

Страница 88: ...during removal Figure 41 Removing the IOM 2 of 2 Installing the IOM About this task See CAUTION bullets regarding electrostatic discharge and anti static protection in the ESD precautions on page 55...

Страница 89: ...IOM that is only partially seated will prevent optimal performance of the enclosure Verify that the module is fully seated before continuing 4 Set the module in position by manually closing the latch...

Страница 90: ...70 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 91: ...0 70 kg 1 50 lb IOM 0 80 kg 1 80 lb IOM fan module 0 345 kg 0 80 lb HS expander module 0 10 kg 0 20 lb Disk Enclosure fully populated with 106 drives maximum weight 145 60 kg 321 00 lb 1 Weights show...

Страница 92: ...rack horizontal impact on all sides 4 in drop tests Vibration operating 0 18 Grms 5Hz to 500 Hz 30 min per axis Vibration non operating 0 54 Grms 6Hz to 200 Hz ISTA 3E Vibration relocation ISTA3H air...

Страница 93: ...Meets EN61000 3 2 EU EN 31000 3 3 EU EN 55024 EU KN 24 KN 35 S Korea Output 12V 164A 12V Standby Voltage 3 5A Hot pluggable Yes Switches and LEDs AC power cable connect and one bi tonal status indicat...

Страница 94: ...74 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 95: ...2 Unpacking the enclosure 3 piece box with packing assembly view The figure below shows an illustrated parts catalog IPC representation of the enclosure master container to complement the assembly vie...

Страница 96: ...Figure 43 Unpacking the enclosure 3 piece box with packing master container 76 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 97: ...t strength L cardboard 2 9 Insert CMA holder cardboard 2 3 Edge protector height each corner 4 10 Foam inner drawer front top 1 4 Insert wall cardboard 1 11 Plastic bag with enclosure belt straps 1 5...

Страница 98: ...78 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 99: ...Japan Ltd 19 21 Nihonbashi Hakozakicho Chuo ku Tokyo 103 8510 Japan INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED...

Страница 100: ...is entirely coincidental COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy...

Страница 101: ...n your country for connection by any means whatsoever to interfaces of public telecommunications networks Further certification may be required by law prior to making any such connection Contact an IB...

Страница 102: ...82 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...

Страница 103: ......

Страница 104: ...IBM...

Отзывы: