background image

Manual LPCI-COM-8SM 

5

Chapter 1: Introduction

 

  

This serial interface card was designed for effective multipoint transmission in any one of three 
modes on each channel. These modes are RS232, RS422 and RS485 (EIA485) protocol. 
The RS485 mode may be run in three manners. It may be run as a standard RTS controlled 
channel, an “Auto RTS (referred to by some as Auto RS485)” mode or as a “4 wire RS485 
mode channel. 
  
The card is 6.60 inches long and may be installed in 3.3 or 5-volt PCI-bus slots of IBM PC or 
compatible computers. The card features eight independent, asynchronous serial ports, type 
16788 buffered UARTs.  
 
This series of cards are available in 4-port and RS-232 only versions. 
 

Features

 

 

  Eight- or four-port RS-232/422/485 serial communications 

  High performance 16788 class UARTs with 64-byte FIFO for each TX and RX 

  Supports data communication speeds up to 921.6kbps 

  Software compatible with all operating systems 

  6’ breakout cable terminating with industry-standard DB9M connectors 

 

Applications 
 

  POS (Point-of-sale) Systems 

 Gaming 

Machines 

 Transportation 

Stations 

 Telecommunications 

 Industrial 

Automation 

  ATM (Automated Teller Machine) Systems 

  Multiple terminal control 

 Office 

Automation 

 Kiosks 

  

Functional Description 
 
RS422 Balanced Mode Operation

 

  

The card supports RS422 communications and uses differential balanced drivers for long range 
and noise immunity. The card also has the capability to add load resistors to terminate the 
communications lines. RS422 communications requires that a transmitter supply a bias voltage 
to ensure a known "zero" state. Also, receiver inputs at each end of the network should be 
terminated to eliminate "ringing". The card supports biasing by default and supports termination 
by jumpers on the card. If your application requires the transmitter to be un-biased, please 
contact the factory. 

Содержание LPCI-COM-4SM

Страница 1: ...go CA 92121 858 550 9559 FAX 858 550 7322 contactus accesio com www accesio com MODEL LPCI COM 8SM LPCI COM 4SM LPCI COM232 8 LPCI COM232 4 Low Profile PCI Multi Port Serial Communications Cards USER...

Страница 2: ...S nor the rights of others IBM PC PC XT and PC AT are registered trademarks of the International Business Machines Corporation Printed in USA Copyright 2004 2005 by ACCES I O Products Inc 10623 Rosell...

Страница 3: ...parts not excluded by warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonable...

Страница 4: ...implified Termination Schematic 11 Data Cable Wiring 11 Baud Rate Ranges 12 Interrupts 12 Table 3 1 WindowsNT Registry Values 12 Figure 3 2 Option Selection Map 13 Other jumpers 14 Chapter 4 Address S...

Страница 5: ...and RX Supports data communication speeds up to 921 6kbps Software compatible with all operating systems 6 breakout cable terminating with industry standard DB9M connectors Applications POS Point of s...

Страница 6: ...against lost data in multitasking operating systems while maintaining 100 percent compatibility with the original IBM serial port The system assigns the address es A crystal oscillator is located on t...

Страница 7: ...etion of the transmission of the character default or can be set to wait up to one additional character s transmission time after data transfer is complete and then disabled The receiver is therefore...

Страница 8: ...es BRKT 551 SCB Strengthening bracket for use with standard height PCI bracket only ADAP9 Screw terminal adaptor DB9F to 9 screw terminals ADAP9 2 Screw terminal adaptor with two DB9F connectors and 1...

Страница 9: ...5 etc CD Software Installation The following instructions assume the CD ROM drive is drive D Please substitute the appropriate drive letter for your system as necessary DOS 1 Place the CD into your CD...

Страница 10: ...DOS Windows NT Windows 3 1 or any other non PNP compliant operating system should set the PNP CMOS option to BIOS or Motherboard Save the option and continue booting the system 9 Most computers shoul...

Страница 11: ...nel are located near the output connector They are labeled by channel The load jumper is labeled LD The other two jumpers are used to connect the transmit and receive lines for the two wire RS485 mode...

Страница 12: ...d to use address 0xFC00 with an interrupt of 05 the values in the Registry are Serial2 subkey PortAddress REG_DWORD 0xFC00 Interrupt REG_DWORD 5 DosDevices REG_SZ COM3 InterruptStatus REG_DWORD 0xFC40...

Страница 13: ...485 2 wire mode This mode may use Auto RTS 2 RS422 3 RS232 4 RS485 4 wire mode The jumpers on the card must be properly placed in order to have the card function properly In order to select the basic...

Страница 14: ...tter and A8 3 RS 485 or RS 422 Loads One jumper must be installed for each channel which requires a load This jumper is located at the cable connector end of the card and is labeled with the channel l...

Страница 15: ...etected on the PCI bus the addresses assigned to each function on each of the cards and the respective IRQs if any allotted Alternatively some operating systems Windows 95 98 2000 XP can be queried to...

Страница 16: ...ndows Programming The card installs into Windows as COM ports Thus the Windows standard API functions can be used In particular CreateFile and CloseHandle for opening and closing a port SetupComm SetC...

Страница 17: ...4 addresses The interrupt status register is located at base 40h Baud Rates On the card the UART clock frequency is 1 8432 MHz Below is a table of popular divisor frequencies Baud Rate Divisor x1 Divi...

Страница 18: ...iques cable connect to chassis ground at the aperture shielded twisted pair wiring etc be used for the input output wiring DB 9 Male Pin for each of Ch A G RS 232 Signals Industry Standard RS 485 Sign...

Страница 19: ...s used are specified as capable of 1Mbps The highest baud rate achievable using the standard oscillator and divisor is 921 6kbps Address Continuously mappable within 0000 to FFFF hex range of PCI bus...

Страница 20: ...l all receive Balanced Differential Signals The reason that RS422 and RS485 devices can drive longer lines with more noise immunity than RS232 devices is that a balanced differential drive method is u...

Страница 21: ...Mode Voltage Range 7V Receiver Input Resistance 4K Table A 2 RS422 Specification Summary To prevent signal reflections in the cable and to improve noise rejection in both the RS422 and RS485 mode the...

Страница 22: ...lowing illustration shows a typical multidrop or party line network Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the line Figure A 1 T...

Страница 23: ...5 2 1 5 9 13 17 21 25 29 3 2 6 10 14 18 22 26 30 4 3 7 11 15 19 23 27 31 5 331 331 331 331 672 672 672 672 6 38 42 46 50 54 58 62 66 7 35 39 43 47 51 55 59 63 8 36 40 44 48 52 56 60 64 9 4 8 12 16 20...

Страница 24: ...anual or just want to give us some feedback please email us at manuals accesio com Please detail any errors you find and include your mailing address so that we can send you any manual updates 10623 R...

Отзывы: