background image

IBM Ethernet Appliance J56S
Getting Started Guide

April 2010
Part Number:

This document describes how to install the IBM Ethernet Appliance J56S.

Contents

About This Guide .............................................................................................3
Step 1: Prepare the Site ...................................................................................4

Rack-Mounting Requirements ...................................................................4
Required Tools ..........................................................................................5

Step 2: Install the Mounting Hardware ............................................................6

Install the Mounting Hardware in a Four-Post Rack or Cabinet or an

Open-Frame Rack ..............................................................................6

Step 3: Install the Device .................................................................................8

Install the Device Using a Lift ....................................................................8
Install the Device Without a Mechanical Lift ...........................................10

Remove Components .......................................................................11
Lift the Chassis into the Rack ............................................................11
Reinstall Components ......................................................................12

Step 4: Connect External Devices and IOC Cables .........................................13

Connect to a Network for Out-of-Band Management ...............................13
Connect a Management Console .............................................................13
Connect the IOC Cables ..........................................................................13

Step 5: Connect Ground and Power Cables ...................................................14

Connect the Grounding Cable .................................................................14
Connect Power to an AC-Powered Ethernet Appliance ............................15
Connect Power to a DC-Powered Ethernet Appliance .............................16

Step 6: Perform Initial Software Configuration ..............................................18
Safety Warnings ............................................................................................23
Compliance Statements for NEBS ..................................................................25

1

Содержание J56S

Страница 1: ...tall the Device Using a Lift 8 Install the Device Without a Mechanical Lift 10 Remove Components 11 Lift the Chassis into the Rack 11 Reinstall Components 12 Step 4 Connect External Devices and IOC Ca...

Страница 2: ...r EMC Requirements 25 Canada 25 European Union 25 Hardware and Software Documentation for IBM Ethernet Appliance J56S 26 Requesting Technical Support 27 Revision History 27 2 IBM Ethernet Appliance J5...

Страница 3: ...rol Boards SCBs in nonredundant fabric configurations By installing different combinations of IOCs and SPCs you can tailor both the number of gigabit ports and the maximum security processing capacity...

Страница 4: ...mounting brackets extend the width to 19 in 48 3 cm The rack must be strong enough to support the weight of the fully configured device up to 163 5 lb 74 2 kg If you stack five fully configured devic...

Страница 5: ...illed rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack Required Tools To unpack the Ethernet appliance and prepare for installation you need the foll...

Страница 6: ...on page 6 2 On the back of each rack rail partially insert a mounting screw into the lowest hole specified in Table 2 on page 6 3 Install the mounting shelf on the back of the rack rails Rest the bott...

Страница 7: ...Figure 2 Mounting Hardware for a Four Post Rack or Cabinet Step 2 Install the Mounting Hardware 7 Step 2 Install the Mounting Hardware...

Страница 8: ...nstall the Device Without a Mechanical Lift on page 10 Install the Device Using a Lift 1 Ensure the rack is in its permanent location and is secured to the building Ensure that the installation site a...

Страница 9: ...f the chassis and the mounting shelf overlap by approximately two inches 6 Slide the chassis onto the mounting shelf until the mounting brackets contact the rack rails The shelf ensures that the holes...

Страница 10: ...ove Components on page 11 Lift the Chassis into the Rack on page 11 Reinstall Components on page 12 Figure 5 Components to Remove from the Front of the Device Figure 6 Components to Remove from the Re...

Страница 11: ...s on removing device components see Install the Ethernet Appliance Without a Mechanical Lift in the IBM Ethernet Appliance J56S Hardware Guide Lift the Chassis into the Rack Lifting the chassis and mo...

Страница 12: ...IL FAIL ESD OK OK OK OK OK OK OK 2 3 4 5 ACO LT YELL O W ALAR M RED ALAR M NC NO C NC NO C RE O RE 1 0 1 2 3 5 4 3 2 1 0 1 0 g004249 Reinstall Components 1 Attach an electrostatic discharge ESD ground...

Страница 13: ...he Routing Engine 3 Plug the other end of the cable into the network device Connect a Management Console 1 Turn off the power to the management device 2 Plug the RJ 45 end of the serial cable into the...

Страница 14: ...ble and cause problems that are difficult to diagnose CAUTION Do not let fiber optic cable hang free from the connector Do not allow fastened loops of cable to dangle which stresses the cable at the f...

Страница 15: ...wrist and connect the strap to one of the ESD points on the chassis For more information about ESD see the IBM Ethernet Appliance J56S Hardware Guide 2 Locate the power cord or cords you will use to c...

Страница 16: ...he PS FAIL LED does not light If any of the status LEDs indicates that the power supply is not functioning normally repeat the installation and cabling procedures Connect Power to a DC Powered Etherne...

Страница 17: ...ctrostatic discharge ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis For more information about ESD see the IBM Ethernet Appliance J56S Hardware Gu...

Страница 18: ...tus LEDs on each power supply faceplate If a DC power supply is correctly installed and functioning normally the PWR OK BRKR ON and INPUT OK LEDs light green steadily Step 6 Perform Initial Software C...

Страница 19: ...ffic interface edit admin set interfaces ge 0 0 0 unit 0 family inet address address prefix length admin set interfaces ge 0 0 1 unit 0 family inet address address prefix length 12 Configure the defau...

Страница 20: ...TVn2KY3 uQe4xzQCxpR2j7sKuV Pa0 SECRET DATA login user admin uid 928 class super user authentication encrypted password 1 cdOPmACd QvreBsJkNR1EF0uurTBkE SECRET DATA services ssh web management http int...

Страница 21: ...ge 0 0 1 0 policies from zone trust to zone untrust policy bob match source address any destination address any application any then permit 18 Commit the configuration to activate it on the device ed...

Страница 22: ...admin commit 20 When you have finished configuring the device exit configuration mode edit admin exit admin 22 Step 6 Perform Initial Software Configuration IBM Ethernet Appliance J56S Getting Started...

Страница 23: ...vice attach an ESD strap to an ESD point and place the other end of the strap around your bare wrist Failure to use an ESD strap could result in damage to the device CAUTION An external Surge Protecti...

Страница 24: ...e it component side up on a flat antistatic surface or in an electrostatic bag When you install the device always make the ground connection first and disconnect it last Wire the DC power supply using...

Страница 25: ...DC return i e DC I as defined in GR 1089 CORE Compliance Statements for EMC Requirements Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A es...

Страница 26: ...appliances and routing operations firewall and security services system alarms and events and network performance This guide also shows how to administer user authentication and access upgrade softwa...

Страница 27: ...sion 01 Initial Release Copyright International Business Machines Corporation 2008 2009 All rights reserved Printed in USA US Government Users Restricted Rights Use duplication or disclosure restricte...