background image

IBM Flex System FC5022 16Gb SAN Scalable Switches

5

Benefits

The switches offer the following key benefits:

Exceptional price/performance for growing SAN workloads

The FC5022 16 Gb Switch delivers exceptional price/performance for growing SAN workloads 

through a combination of market-leading 1600 MB/sec throughput per port and an affordable 
high-density, 12-port to 48-port  form factor. 

Enhanced server performance while using 16 Gb Gen 5 FC technology

IBM testing demonstrates that using 16 Gb FC adapters on the server and the FC5022 modules can 

help achieve the following server enhancements, even if 8 Gb FC storage is used:

o

Up to 30-50% better virtual machine density and higher number of concurrent users due to 

increased storage bandwidth
o

Up to 20-40% fewer servers required to support the workload specified

o

Twice lower number and higher speed of inter-switch links required in scalable SANs

o

Higher reliability and availability of services due to fewer number of components used to build the 

solution
o

Twice faster access to the business critical data

o

Lower acquisition costs due to fewer number of systems and components

o

Shorten ROI time frame and decrease overall TCO with the efficient utilization of server resources 

and lower power, cooling, and management costs
o

See IBM Redpaper “Positioning IBM Flex System 16 Gb Fibre Channel Fabric for 

Storage-Intensive Enterprise Workloads” for details:

http://www.redbooks.ibm.com/abstracts/redp4921.html?Open

Superior scalability both for internal and external ports that reduces costs and increases availability

The FC5022 16 Gb switch is the only switch that provides up to 28 internal server facing FC ports, 

which allows the Flex Chassis to scale to 28 server ITEs in a single chassis (when using double 
density half-width ITEs) that lowers the overall per-server cost of the solution. These 28 internal ports 
also enable greater path redundancy for ITEs using the 4-port FC mezzanine adapters. Additionally, 
the FC5022 offers an industry leading 20 external SFP+ ports that allows for multi-chassis scalability 
up to 18 chassis without the use of external FC switches, thereby greatly reducing the overall cost of 
the Flex Solution. 

Accelerating fabric deployment and serviceability with Brocade ClearLink and Fabric Vision

Brocade ClearLink is a feature supported by the FC5022 16 Gb Switch that enables administrators to 

quickly identify and isolate 16 Gbps optic, port, and cable problems, reducing fabric deployment and 
diagnostic times. Brocade Fabric Vision Technology offers innovative diagnostic, monitoring, and 
management capabilities to help administrators avoid problems, maximize application performance, 
and reduce operational costs. 

A building block for virtualized, private cloud storage

The FC5022 16 Gb Switch supports multi-tenancy in cloud environments through VM-aware 

end-to-end visibility and monitoring, Quality of Service (QoS), and fabric-based advanced zoning 
features. The FC5022 enables secure long distance extensions to virtual private or hybrid clouds with 
dark fiber support, as well as in-flight encryption and data compression.

Simplified interconnect to existing SAN environments with Brocade Access gateway (NPIV) 

operational mode

All models of the FC5022 16 Gb Switch can be deployed as a full-fabric switch or as an Access 

Gateway, which simplifies fabric topologies and heterogeneous fabric connectivity.  Access Gateway 

Содержание FC5022

Страница 1: ...ue differentiation in the market including Increased server density The 28 internal FC ports allow up to 28 Information ITEs in a single chassis which lowers the average server cost of the solution Gr...

Страница 2: ...ex System FC5022 16 Gb Fabric Watch Upgrade 00Y3320 A3HN ESW3 IBM Flex System FC5022 16 Gb ISL Trunking Upgrade 00Y3322 A3HP ESW4 The part numbers for the switches include the following items One IBM...

Страница 3: ...on by model for IBM Flex System FC5022 switches Table 3 Feature comparison by model Feature 24 port 16 Gb ESB SAN switch 24 port 16 Gb SAN switch 16 Gb SAN switch Number of licensed ports 24 24 12 Num...

Страница 4: ...bre Channel FC ports After all port licenses have been assigned you can manually move those licenses from one port to another Because this is dynamic no defined ports are reserved except ports 0 and 2...

Страница 5: ...the only switch that provides up to 28 internal server facing FC ports which allows the Flex Chassis to scale to 28 server ITEs in a single chassis when using double density half width ITEs that lowe...

Страница 6: ...for 16 Gb SFP or 8 Gb SFP transceivers supporting 4 Gb 8 Gb and 16 Gb port speeds supported SFP modules are listed in Table 2 Ports are activated with the Dynamic Ports on Demand feature External port...

Страница 7: ...ng functionality contained within the Ethernet Control MIB II RFC1213 MIB UUID put into MIB structure End to end optics and link validation Ability to send switch events and syslogs to the IBM Chassis...

Страница 8: ...FC standards FC AL 2 INCITS 332 1999 FC GS 5 ANSI INCITS 427 includes the following FC GS 4 ANSI INCITS 387 2004 FC IFR INCITS 1745 D revision 1 03 under development FC SW 4 INCITS 418 2006 includes...

Страница 9: ...route to two switch bays for redundancy and performance Figure 2 Location of the switch bays in the IBM Flex System Enterprise Chassis The connections between the 2 port adapters that are installed i...

Страница 10: ...must be installed in a corresponding slot of the compute node slot A1 when switches are installed in bays 1 and 2 or slot A2 when switches are in bays 3 and 4 With compute nodes that have an integrat...

Страница 11: ...Module bay 2 Port 3 Module bay 1 Slot 3 full wide compute nodes only Port 4 Module bay 2 Port 1 Module bay 3 Port 2 Module bay 4 Port 3 Module bay 3 Slot 4 full wide compute nodes only Port 4 Module b...

Страница 12: ...Y2379 A3HU A3HU Yes IBM Flex System FC5052 2 port 16Gb FC Adapter 95Y2386 EC23 A45R Yes IBM Flex System FC5054 4 port 16Gb FC Adapter 95Y2391 EC2E A45S Yes IBM Flex System FC5172 2 port 16Gb FC Adapte...

Страница 13: ...the switch physically by illuminating via the management software The Error LED switch module error indicates that the switch module has failed the POST or detected an operational fault One mini USB R...

Страница 14: ...5 km LC Management ports External 1 GbE management port UTP Category 5 5E and 6 up to 100 meters RJ 45 External RS 232 management port DB 9 to mini USB or RJ 45 to mini USB console cable comes with op...

Страница 15: ...eports and certificates per EN60950 1 2001 IEC60950 1 2001 Canada CSA C22 2 No 950 or 60950 Germany TUV VDE IEC 950 EN 60950 TUV component report IEC60950 CB Report and Certificate FCC Title 47 CFR Pa...

Страница 16: ...dapters installed in compute nodes Table 10 shows the components used when connecting the 16 Gb FC adapters to the 16 Gb FC switches Table 10 Components used when connecting the 16 Gb FC adapters to t...

Страница 17: ...ssi cgi bin ssialias infotype dd subtype ca htmlfid 897 ENUS112 053 IBM US Announcement Letter for the 16Gb 24 port SAN switch http ibm com common ssi cgi bin ssialias infotype dd subtype ca htmlfid...

Страница 18: ...part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurri...

Страница 19: ...s of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the ap...

Отзывы: