12
OpenPower 720 Technical Overview and Introduction
1.5 System racks
The Enterprise Rack Models T00 and T42 are 19-inch wide racks for general use with
IBM
Sserver
OpenPower, p5, pSeries, and RS/6000 rack-based or rack drawer-based
systems. The racks provide increased capacity, greater flexibility, and improved floor space
utilization.
The OpenPower 720 uses a 4U rack-mounted server drawer.
If an OpenPower 720 system is to be installed in a non-IBM rack or cabinet, you should
ensure that the rack conforms to the EIA
1
standard EIA-310-D (see 1.5.6, “OEM rack” on
page 16).
1.5.1 IBM RS/6000 7014 Model T00 Enterprise Rack
The 1.8-meter (71 inch) Model T00 is compatible with past and present OpenPower, p5,
pSeries, and RS/6000 racks and is designed for use in all situations that have previously used
the older rack models R00 and S00. The T00 rack has the following features:
36 EIA units (36U) of usable space.
Optional removable side panels.
Optional highly perforated front door.
Optional side-to-side mounting hardware for joining multiple racks.
Standard black or optional white color in OEM format.
Increased power distribution and weight capacity.
An optional reinforced (ruggedized) rack feature (FC 6080) provides added earthquake
protection with modular rear brace, concrete floor bolt-down hardware, and bolt-in steel
front filler panels.
Support for both AC and DC configurations.
DC rack height is increased to 1926 mm (75.8 inches) if a power distribution panel is fixed
to the top of the rack.
Up to four Power Distribution Units (PDUs) can be mounted in the proper bays, but others
can fit inside the rack. See 1.5.3, “AC Power Distribution Unit and rack content” on
page 13.
Optional rack status beacon (FC 4690). This beacon is designed to be placed on top of a
rack and cabled to servers, such as a OpenPower 720, and other components, such as a
Note: Only Express Product Offerings configurations will have SKU Identifiers. No BTO
configuration even if it meets the definition of an Express Product Offering configuration will
have SKU Identifier. Any modifications to an Express hardware configuration will suppress
the SKU Identifier.
1
Electronic Industries Alliance (EIA). Accredited by American National Standards Institute (ANSI), EIA provides a
forum for industry to develop standards and publications throughout the electronics and high-tech industries.
Note: It is the customer’s responsibility to ensure that the installation of the drawer in the
preferred rack or cabinet results in a configuration that is stable, serviceable, safe, and
compatible with the drawer requirements for power, cooling, cable management, weight,
and rail security.