Power
problems
Power
symptom
Suggested
action
The
blade
server
does
not
turn
on.
1.
Make
sure
that:
a.
The
power-on
LED
on
the
front
of
the
BladeCenter
unit
is
lit.
b.
The
LEDs
on
all
the
BladeCenter
power
modules
are
lit.
c.
If
the
blade
server
is
in
blade
bays
7
through
14,
power
modules
are
in
power-module
bays
1,
2,
3,
and
4.
d.
The
power-on
LED
on
the
blade-server
control
panel
is
flashing
slowly.
v
If
the
power-on
LED
is
flashing
rapidly
and
continues
to
do
so,
the
blade
server
is
not
communicating
with
the
management
module;
reseat
the
blade
server
and
go
to
step
v
If
the
power
LED
is
off,
either
the
blade
bay
is
not
receiving
power,
the
blade
server
is
defective,
or
the
LED
information
panel
is
loose
or
defective.
e.
Local
power
control
for
the
blade
server
is
enabled
(use
the
BladeCenter
management-module
Web
interface
to
make
sure),
or
the
blade
server
was
instructed
through
the
management
module
(Web
interface)
to
turn
on.
2.
If
you
just
installed
an
option
in
the
blade
server,
remove
it,
and
restart
the
blade
server.
If
the
blade
server
now
turns
on,
troubleshoot
the
option
(see
the
documentation
that
comes
with
the
option
for
information).
3.
Try
another
blade
server
in
the
blade
bay;
if
it
works,
replace
the
faulty
blade
server.
4.
If
the
problem
remains,
have
the
blade
server
serviced.
Memory
problems
Memory
symptom
Suggested
action
The
amount
of
system
memory
displayed
is
less
than
the
amount
of
physical
memory
installed.
Make
sure
that:
v
The
memory
modules
are
seated
correctly.
v
You
have
installed
the
correct
type
of
memory.
v
All
banks
of
memory
on
the
DIMMs
are
enabled.
The
server
might
have
automatically
disabled
a
DIMM
bank
when
it
detected
a
problem.
v
The
DIMMs
are
not
defective.
If
a
DIMM
has
failed,
an
8-digit
error
code
will
be
displayed
in
the
following
format:
“25C0
xx
yy
”.
To
identify
the
specific
DIMM
that
has
failed,
see
“25C0
xx
yy
”
in
beginning
on
page
and
obtain
the
values
for
“
xx
”
and
“
yy
”.
Replace
the
failing
DIMM;
then,
restart
the
server.
v
The
blade-server
firmware
code
automatically
updated
the
memory
configuration,
if
you
changed
the
memory.
If
the
problem
remains,
call
for
service.
Chapter
10.
Solving
problems
89
Содержание eServer BladeCenter JS20 Type 8842
Страница 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ERserver...
Страница 8: ...vi BladeCenter JS20 Type 8842 Installation and User s Guide...
Страница 28: ...12 BladeCenter JS20 Type 8842 Installation and User s Guide...
Страница 72: ...56 BladeCenter JS20 Type 8842 Installation and User s Guide...
Страница 114: ...98 BladeCenter JS20 Type 8842 Installation and User s Guide...
Страница 136: ...120 BladeCenter JS20 Type 8842 Installation and User s Guide...
Страница 149: ......
Страница 150: ...Part Number 25K8416 Printed in USA 1P P N 25K8416...