32
IBM® xSeries 250: Installation Guide
3.
Install the hard disk drive in the hot-swap bay:
a.
If there is a small gap above or below the drive, separate the gap filler from
the slim filler panel and insert it in the gap.
Note:
A drive placement guide is located on the inside edge of the bezel. The
drive placement guide indicates the placement for slim-high drives.
The guide also shows the SCSI ID assigned to the drive.
b. Ensure that the tray handle is open (that is, perpendicular to the drive).
c.
Align the drive assembly with the guide rails in the bay.
d. Gently push the drive assembly into the bay until the drive stops.
e.
Push the tray handle to the closed (locked) position.
f.
Check the hard disk drive status indicators to verify that the hard disk drive
is operating properly.
If the amber hard-disk status light for a drive is lit continuously, that
individual drive is faulty and needs to be replaced. If the green hard-disk
activity light is flashing, the drive is being accessed.
Note:
If your server has an optional ServeRAID adapter installed, you must
configure your disk arrays after installing hard disk drives. Refer to the
information that comes with your ServeRAID adapter for details.
Содержание eServer 250 xSeries
Страница 3: ...IBM IBM xSeries 250 Installation Guide SC21 P901 90 ...
Страница 6: ...iv IBM xSeries 250 Installation Guide ...
Страница 12: ...x IBM xSeries 250 Installation Guide ...
Страница 18: ...6 IBM xSeries 250 Installation Guide ...
Страница 56: ...44 IBM xSeries 250 Installation Guide ...
Страница 58: ...46 IBM xSeries 250 Installation Guide ...
Страница 66: ...54 IBM xSeries 250 Installation Guide ...
Страница 83: ......
Страница 84: ...IBM Part Number 21P9019 Printed in the United States of America 21P9 19 ...