__
35.
Press
Enter
to
confirm
your
choice.
The
configuration
will
start
and
may
take
30
to
60
minutes
to
complete.
__
36.
When
the
device
parity
protection
is
complete,
the
message
Selected
units
have
been
included
successfully
appears
on
the
Work
with
disk
configuration
display.
__
37.
Select
Display
disk
configuration
on
the
Work
with
disk
configuration
display
and
press
Enter.
__
38.
Select
Display
disk
configuration
status
on
the
Display
disk
configuration
display
and
press
Enter.
__
39.
If
you
have
more
than
one
ASP,
determine
the
auxiliary
storage
pool
(ASP)
to
which
you
want
to
add
the
disk
units.
__
40.
Press
F12,
twice.
__
41.
Select
Add
units
to
the
ASPs
and
balance
data
on
the
Work
with
disk
configuration
display.
Press
Enter.
__
42.
Specify
the
ASP
that
you
determined
in
step
on
the
Specify
ASPs
to
Add
Units
to
display.
Press
Enter.
__
43.
The
Confirm
Add
Units
display
appears
showing
the
configuration
your
system
will
have
when
the
add
operation
completes.
Note:
If
you
have
selected
the
wrong
ASP,
press
F12
to
change
your
options.
Press
the
Enter
key
to
continue.
The
add
process
will
take
several
minutes
to
complete.
__
44.
When
the
message
Selected
units
have
been
added
successfully
appears,
return
to
the
Main
Menu
.
(Press
F3
three
times
and
press
Enter.)
__
45.
Go
to
step
__
46.
Select
Display
disk
configuration
on
the
Work
with
Disk
Configuration
display.
Press
Enter.
__
47.
Select
Display
disk
configuration
status
on
the
Display
Disk
Configuration
display.
Press
Enter.
__
48.
If
you
have
more
than
one
ASP,
determine
the
auxiliary
storage
pool
(ASP)
to
which
you
want
to
add
the
disk
units.
__
49.
Press
F12,
twice.
__
50.
Select
Add
units
to
ASPs
on
the
Work
with
Disk
Configuration
display.
Press
Enter.
__
51.
Specify
the
number
of
the
ASP
to
which
you
want
to
add
the
disk
unit.
The
system
ASP
is
ASP
1
.
Press
Enter.
Notes:
a.
When
an
even
number
of
disk
units
are
added
to
a
mirrored
ASP,
they
will
automatically
become
mirrored
protected.
b.
If
ASP
is
mirror
protected,
disk
units
must
be
added
in
pairs.
__
52.
The
Confirm
Add
Units
display
appears
showing
the
configuration
your
system
will
have
when
the
add
operation
completes.
Chapter
3.
Install
43xx
disk
units
19
Содержание E Server i Series
Страница 1: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver...
Страница 2: ......
Страница 3: ...iSeries 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure Version 5 ERserver...
Страница 6: ...iv 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 34: ...28 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 37: ...270 800 or 810 in a rack Open or remove the front cover 31...
Страница 40: ...7104 or 7116 expansion unit 34 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 41: ...820 system unit Disk unit locations 35...
Страница 42: ...825 system unit 36 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 60: ...54 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 66: ...60 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 74: ...68 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 76: ...70 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 84: ...recommended cables and connectors 78 43xx Disk Unit 71xx Disk Expansion Unit 71xx Disk Unit Enclosure V5R3...
Страница 85: ......
Страница 86: ...Printed in USA...