background image

the BSY bit whenever it is ready to accept commands. Device 0 may assert DASP-
to indicate device activity.

Hard Reset, Soft Reset

If Device 1 is present Device 0 shall read PDIAG- to determine when it is valid to
clear the BSY bit and whether Device 1 has reset without any errors, otherwise
Device 0 shall simply reset and clear the BSY bit. DASP- is asserted by Device 0
(and Device 1 if it is present) in order to indicate device active.

Execute Device Diagnostic

If Device 1 is present, Device 0 shall read PDIAG- to determine when it is valid to
clear the BSY bit and if Device 1 passed or failed the EX E C UT E DEVICE DIAG-
NOSTIC command, otherwise Device 0 shall simply execute its diagnostics and then
clear the BSY bit. DASP- is asserted by Device 0 (and Device 1 if it is present) in
order to indicate the device is active.

In all the above cases: Power on, RESET-, Soft reset, and the E X EC U T E DEVICE DIAGNOSTIC

command the Device 0 Error register is shown in Figure 65.

ÚÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÂÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿

³

D e v i c e 1

³

P D I A G

Ä

³

D e v i c e 0

³³

E r r o r

³

³

P r e s e n t ?

³

A s s e r t e d ?

³

P a s s e d

³³

R e g i s t e r

³

ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÅÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´

³

Y e s

³

Y e s

³

Y e s

³³

0 1 h

³

³

Y e s

³

Y e s

³

N o

³³

0 x h

³

³

Y e s

³

N o

³

Y e s

³³

8 1 h

³

³

Y e s

³

N o

³

N o

³³

8 x h

³

³

N o

³

( n o t r e a d )

³

Y e s

³³

0 1 h

³

³

N o

³

( n o t r e a d )

³

N o

³³

0 x h

³

ÀÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÁÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

W h e r e x i n d i c a t e s t h e a p p r o p r i a t e D i a g n o s t i c C o d e f o r
t h e P o w e r o n , R E S E T - , S o f t r e s e t , o r D e v i c e D i a g n o s t i c
e r r o r .

Figure 65. Reset error register values

10.3 Sector Addressing Mode

All addressing of data sectors recorded on the device's media is by a logical sector address. The logical CHS
address for DTTA-3xxxxx is different from the actual physical CHS location of the data sector on the disk
media.

DTTA-3xxxxx support both Logical CHS Addressing Mode and LBA Addressing Mode as the sector
addressing mode.

The host system may select either the currently selected CHS translation addressing or LBA addressing on a
command-by-command basis by using the L bit in the DEVICE/HEAD register. So a host system must set
the L bit to 1 if the host uses LBA Addressing mode.

General Operation Descriptions

75

Содержание DTTA-350320

Страница 1: ...OEM HARD DISK DRIVE SPECIFICATIONS for DTTA 3xxxxx 16 8GB 3 2GB 3 5 Inch Hard Disk Drive with ATA Interface Revision 2 0 S00K 0286 02 ...

Страница 2: ......

Страница 3: ...OEM HARD DISK DRIVE SPECIFICATIONS for DTTA 3xxxxx 16 8GB 3 2GB 3 5 Inch Hard Disk Drive with ATA Interface Revision 2 0 S00K 0286 02 ...

Страница 4: ...his publication may contain reference to or information about IBM products machines and programs programming or services that are not announced in your country Such references or infor mation must not be construed to mean that IBM intends to announce such IBM products programming or services in your country Technical information about this product is available by contacting with local IBM represen...

Страница 5: ...s 15 5 0 Physical Format 17 5 1 Shipped Format 17 6 0 Specification 19 6 1 Electrical interface specification 19 6 1 1 Connectors 19 6 1 2 Signal Definition 20 6 1 3 Interface Logic Signal Levels 23 6 2 Signal Timings 24 6 2 1 Reset Timings 24 6 2 2 PIO Timings 25 6 2 3 DMA Timings 27 6 2 4 Ultra DMA Timings 29 6 2 5 Addressing of HDD Registers 37 6 2 6 Cabling 37 6 3 Jumper Settings 38 6 3 1 Loca...

Страница 6: ... C Tick Mark 58 6 12 Safety 59 6 12 1 Underwriters Lab UL Approval 59 6 12 2 Canadian Standards Authority CSA Approval 59 6 12 3 IEC Compliance 59 6 12 4 German Safety Mark 59 6 12 5 Flammability 59 6 12 6 Secondary Circuit Protection 59 6 13 Packaging 59 Part 2 ATA Interface Specification 61 7 0 General 63 7 1 Introduction 63 7 2 Terminology 63 8 0 Deviations From Standard 65 9 0 Registers 67 9 1...

Страница 7: ...word 80 10 7 4 Operation example 81 10 7 5 Command Table 84 10 8 Protected Area Function 86 10 8 1 Example for operation In LBA mode 86 10 9 Write Cache Function 87 10 10 Reassign Function 87 10 10 1 Auto Reassign Function 88 10 11 Automatic Drive Maintenance ADM 88 11 0 Command Protocol 89 11 1 PIO Data In Commands 89 11 2 PIO Data Out Commands 90 11 3 Non Data Commands 91 11 4 DMA Commands 92 11...

Страница 8: ... Multiple C6h 145 12 30 Sleep E6h 99h 146 12 31 S M A R T Function Set B0h 147 12 31 2 Device Attributes Data Structure 150 12 31 3 Device Attribute Thresholds Data Structure 154 12 31 4 Error Reporting 155 12 32 Standby E2h 96h 157 12 33 Standby Immediate E0h 94h 159 12 34 Write Buffer E8h 160 12 35 Write DMA CAh CBh 161 12 36 Write DMA Queued CCh 163 12 37 Write Long 32h 33h 165 12 38 Write Mult...

Страница 9: ...rpm Note The specifications are subject to change without notice 1 1 Glossary Word Meaning Kbpi 1 000 Bit Per Inch Mbps 1 000 000 Bit per second GB 1 000 000 000 bytes MB 1 000 000 bytes KB 1 000 bytes 32 KB 32 x 1 024 bytes 64 KB 64 x 1 024 bytes Mb sq in 1 000 000 bits per square inch MLC Machine Level Control S M A R T Self Monitoring and Analysis Reporting Technology 1 2 General Caution The dr...

Страница 10: ...2 OEM Specifications for DTTA 3xxxxx ...

Страница 11: ...Kbytes Write Cache Queued feature support On The Fly correction 12 Bytes Automatic Error Recovery procedures for read and write commands Self Diagnostics on Power on and resident diagnostics Data Trandfer PIO Mode 4 16 6 MB sec Ultra DMA 33 33 3 MB sec CHS and LBA mode Transparent Defect Management with ADR Automatic Defect Reallocation Power Saving modes S M A R T function support Seculity functi...

Страница 12: ...4 OEM Specifications for DTTA 3xxxxx ...

Страница 13: ...Part 1 Functional Specification Copyright IBM Corp 1998 5 ...

Страница 14: ...6 OEM Specifications for DTTA 3xxxxx ...

Страница 15: ...es DTTA 351680 16 9 16383 16 15 63 33 022 080 16 907 304 960 DTTA 351350 13 5 16383 16 15 63 26 414 640 13 524 295 680 DTTA 351290 12 9 16383 16 15 63 25 385 472 12 997 361 664 DTTA 351010 10 1 16383 16 15 63 19 807 200 10 141 286 400 DTTA 350840 8 4 16383 16 15 63 16 514 064 8 455 200 768 DTTA 350640 6 4 12592 13431 16 15 63 12 692 736 6 498 680 832 DTTA 350430 4 3 8400 8960 16 15 63 8 467 200 4 ...

Страница 16: ... 3 Ultra DMA 33 Data Buffer Size KB 464 464 Rotational Speed RPM 5400 7200 Average Latency msec 5 56 4 17 Recording Density Kbpi 196 1 max 178 1 max Track Density TPI 13 700 13 700 Areal Density Gb sq in 2 687 max 2 440 max Number of Zone 8 8 Number of Data Disks 5 4 3 3 2 2 1 5 5 4 Number of Data Heads 10 8 6 5 4 3 2 10 9 7 Servo Method Embeded Sector Servo Embeded Sector Servo 8 OEM Specificatio...

Страница 17: ...command when the requested data is not in the buffer exclude Physical seek time Latency time Figure 3 Command Overhead Note The above table gives an average time 3 3 2 Mechanical Positioning 3 3 2 1 Average Seek Time Without Command Overhead Including Settling Figure 4 Mechanical Positioning Performance Typical and Max are given throughout the performance specification by Typical Average of the dr...

Страница 18: ...eek Length 1 to max Tn in Inward measured seek time for a n track seek Tn out Outward measured seek time for a n track seek 3 3 2 2 Full Stroke Seek Without Command Overhead Including Settling Figure 5 Full Stroke Seek Time Full stroke seek is measured as the average of 1000 full stroke seeks with a random head switch from both directions inward and outward 3 3 2 3 Head Switch Time Head Skew Figur...

Страница 19: ...and outward 3 3 2 6 Average Latency Figure 9 Latency Time 3 3 3 Drive Ready Time Figure 10 Drive Ready Time Ready The condition in which the drive is able to perform a media access command e g read write immediately Power On This includes the time required for the internal self diagnostics Note Max Power On to ready Time is the maximum time period Device 0 waits up to for Device 1 to assert PDIAG ...

Страница 20: ...inder 512 B of Surface per cylinder 1 Head Switch Time C Cylinder Change Time D of Surface One Revolution Time Instantaneous Buffer Host Transfer Rate Mbyte sec defines the maximum data transfer rate on AT Bus It also depends on the speed of the host The measurement method is given in 3 3 5 Throughput on page 13 Description DTTA 35xxxx DTTA 37xxxx Disk Buffer Transfer Zone 0 Instantaneous typical ...

Страница 21: ...tency sec D Sustained DiskÄBuffer Transfer Rate byte sec E BufferÄHost Transfer Rate byte sec DRQ Data ReQuest interval sec 3 3 5 2 Random Access The above table gives the time required to execute a total of 1000x read commands which access a random LBA T A B C 512 D 512 E DRQ 4096 where T Calculated Time sec A Command Process Time Command overhead sec B Average Seek Time sec C Latency sec D Avera...

Страница 22: ... or hard reset can change the mode to standby Notes 1 Upon Power down or Spindle stopped a head locking mechanism will secure the heads in the ID parking position 3 3 6 1 Mode Transition Time Figure 13 Mode Transition Time Note The actual spin down time will exist however the command will be processed immediately From To DTTA 371440 DTTA 371290 DTTA 371010 DTTA 351680 DTTA 351350 DTTA 351290 DTTA ...

Страница 23: ...data in the write cache have been flushed onto the disk Checking just before power off is recommended to prevent data loss To confirm successful completion of Software Reset To confirm successful completion of Flush Cache command To confirm successful completion of Check Power Mode command 4 3 Equipment Status Equipment status is available to the host system any time the drive is not ready to read...

Страница 24: ...16 OEM Specifications for DTTA 3xxxxx ...

Страница 25: ... tracks of inner zone Ä Ä ÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂ Ä Ä N N 1 N 2 N 3 Defect Defect Ä Ä ÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁ Ä Ä A A ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ Skip Skip Defects are skipped without any constraint such as track or cylinder boundary The calculation from LBA to physical is done automatically by internal table Note There is possibility to reallocate sectors...

Страница 26: ...18 OEM Specifications for DTTA 3xxxxx ...

Страница 27: ... mate with AMP part 1 480424 0 using AMP pins part 350078 4 strip or part 61173 4 loose piece or their equivalents Pin assignments are shown below Figure 14 Power Connector Pin Assignments 6 1 1 2 AT Signal Connector The AT signal connector is a 40 pin connector Pin 1 2 3 4 Voltage 12 V GND GND 5 V Copyright IBM Corp 1998 19 ...

Страница 28: ... Notes 1 O designates an output from the Drive 2 I designates an input to the Drive 3 I O designates an input output common 4 OC designates Open Collector or Open Drain output 5 The signal lines marked with are redefined during the Ultra DMA protocol to provide special func tions These lines change from the conventional to special definitions at the moment the Host decides to allow a DMA burst if ...

Страница 29: ...6 bit wide data word This signal is an Open Drain output with 24 mA sink capability and an external resistor is needed to pull this line to 5 volts DASP This is a time multiplexed signal which indicates that a drive is active or that device 1 is present This signal is driven by Open Drain driver and internally pulled up to 5 volts through a 10kΩ resistor During Power On initialization or after RES...

Страница 30: ... is a 3 state line with 24mA sink capability and internally pulled down to GND through 10 kΩ resistor HDMARDY Ultra DMA This signal is used only for Ultra DMA data transfers between host and drive HDMARDY is a flow control signal for Ultra DMA data in bursts This signal is held asserted by the host to indicate to the device that the host is ready to receive Ultra DMA data in transfers The host may...

Страница 31: ...an Ultra DMA data in transfer Note The termination resistors at the device side are implemented as follows Device Termination implemented on HDD side 33 ohm for DD0 thru DD15 DMARQ INTRQ 82 ohm for CS0 CS1 DA00 DA01 DA02 DIOR DIOW DMACK 22 ohm for IORDY 6 1 3 Interface Logic Signal Levels The interface logic signal has the following electrical specifications Inputs Input High Voltage Ä 2 0 V min I...

Страница 32: ...ÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄ PARAMETER DESCRIPTION Min Max usec sec ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄ T0 ÄRESET low width 25 ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄ T1 ÄRESET high to not BUSY ÄÄ 31 ÀÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÙ Figure 17 System Reset timing 24 OEM Specifications for ...

Страница 33: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ IORDY ÀÄÄÄÄÄÄÄÄÄÙ ÄÄT11ÄÄ ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄ PARAMETER DESCRIPTION MIN MAX Note nsec nsec ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄ T0 Cycle time 120 Ä T1 ÄCS0Ä1 DA00Ä02 valid to ÄDIOR ÄDIOW active 25 Ä T2 ÄDIOR ÄDIOW pulse width 70 Ä T2I ÄDIOR ÄDIOW recovery 25 ...

Страница 34: ...ors and read multiple operations the interval from the end of negation of the DRQ bit until setting of the next DRQ bit is as follows In case that a host reads the status register only before the sector or block transfer DRQ interval DRQ interval 5 2µsec In case that a host reads the status register after or both before and after the sector or block transfer DRQ interval 14 4µsec 26 OEM Specificat...

Страница 35: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÄÄÄÄÄTGÄÄÄÄÄ TH Ä ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ WRITE DATA ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ nsec ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄ PARAMETER DESCRIPTION MIN MAX Note ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄ T0 Cycle time 240 Ä TC ÄDMACK active to DMARQ inactive Ä 80 TD ÄHIOR ÄHIOW ...

Страница 36: ...RITE DATA ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄ ÀÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÙ nsec ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄ PARAMETER DESCRIPTION MIN MAX Note ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄ T0 Cycle time 120 Ä TD ÄHIOR ÄHIOW pulse width 70 Ä TE ÄHIOR data setup 20 Ä TF ÄHIOR data hold 5 Ä TG ÄHIOW data setup 20 Ä TH ÄH...

Страница 37: ... Data ÀÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Host drives DB Device drives DB nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tui Unlimited interlock...

Страница 38: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tsr Strobe to ready response time Ä 50 Ä 30 Ä 20 Trfs Ready to final strobe time Ä 75 Ä 60 Ä 50 ÀÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 39: ...ÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device drives DB Host drives DB nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Trfs Ready to final strobe time Ä 75 Ä 60 Ä 50 Trp Ready to pause time 160 Ä 125 Ä 100 Ä Tli...

Страница 40: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device drives DB Host drives DB nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tss Time from strobe to stop assertion 50 Ä 50 Ä 50 Ä Tli Limited interlock time 0 150 0 150 0...

Страница 41: ...ÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Host drives DB ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tui Unlimited interlock time 0 Ä 0 Ä 0 Ä Tack Setup time before ÄDMACK assertion 20 Ä...

Страница 42: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tsr Strobe to ready response time Ä 50 Ä 30 Ä 20 Trfs Ready to final strobe time Ä 75 Ä 60 Ä 50 ÀÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 43: ...ÄÄÄÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Host drives DB ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Trfs Ready to final strobe time Ä 75 Ä 60 Ä 50 Trp Ready to pause time 160 Ä 125...

Страница 44: ...ÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Host drives DB ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ nsec ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ MODE0 MODE1 MODE2 PARAMETER DESCRIPTION ÃÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄÅÄÄÄÄÂÄÄÄÄ MIN MAX MIN MAX MIN MAX ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄ Tss Time from strobe to stop assertion 50 Ä 50 Ä 50 Ä Tli Limited interlock time 0 ...

Страница 45: ...eg 0 1 1 0 0 Cylinder low Reg Cylinder low Reg 0 1 1 0 1 Cylinder high Reg Cylinder high Reg 0 1 1 1 0 Drive Head Reg Drive Head Reg 0 1 1 1 1 Status Reg Command Reg ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Control Block Registers ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 1 0 1 1 0 Alt Status Reg Device control Reg 1 0 1 1 1 Drive address Re...

Страница 46: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄ ÚÄÄÄ ÚÄÄÄ ÚÄÄÄ ÚÄÄÄ I G E C A ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÚÄÄÄÄÄ ÚÄÄÄ ÚÄÄÄ ÚÄÄÄ ÚÄÄÄ H F D B ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÙ ÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Figure 30 Jumper Pin Assignment 6 3 3 Jumper Function Device 0 Device 1 Cable Select and Device 0 Forcing Device 1 Present can be selec...

Страница 47: ...ABLE SELECT H F D B ÀÄÙ ÀÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄ ÚÄ I G E C A DEVICE 0 H F D B Forcing DEVICE 1 PRESENT ÀÄÙ ÀÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Figure 31 Jumper Block Setting Position Notes 1 All other setting patterns are reserved Do not make other setting 2 When CABLE SELECT is specified AT interface signal 28 CSEL is referred to determin the d...

Страница 48: ...D B ÀÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄ ÚÄ ÚÄÄÄÄÄÄÄ I G E C A ÀÄÄÄÄÄÄÄÙ DEVICE 0 H F D B Forcing DEVICE 1 PRESENT ÀÄÙ ÀÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Figure 32 Jumper Block Setting Position Notes 1 All other setting patterns are reserved Do not make other setting 2 When CABLE SELECT is specified AT interface signal 28 CSEL is referred to determin the dr...

Страница 49: ...ÀÄÄÄÄÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄ ÚÄ I G E C A DEVICE 0 ÚÄÄÄÄÄÄÄ Forcing DEVICE 1 PRESENT H F D B ÀÄÙ ÀÄÙ ÀÄÄÄÄÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Figure 33 Jumper Block Setting Position Notes 1 All other setting patterns are reserved Do not make other setting 2 When CABLE SELECT is specified AT interface signal 28 CSEL is referred to determin the ...

Страница 50: ...D B ÀÄÙ ÀÄÄÄÄÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄ ÚÄ ÚÄÄÄÄÄÄÄ I G E C A ÀÄÄÄÄÄÄÄÙ DEVICE 0 ÚÄÄÄÄÄÄÄ Forcing DEVICE 1 PRESENT H F D B ÀÄÙ ÀÄÙ ÀÄÄÄÄÄÄÄÙ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Figure 34 Jumper Block Setting Position Notes 1 All other setting patterns are reserved Do not make other setting 2 When CABLE SELECT is specified AT interface signal 28 CSEL i...

Страница 51: ...ude 300 to 3048 m Non Operating Conditions Temperature 40 to 65 C Relative Humidity 5 to 95 R H non condensing Maximum Wet Bulb Temperature 35 C non condensing Maximum Temperature Gradient 15 C Hour Altitude 300 to 12 000 m Note The system has to provide sufficient ventilation to maintain a surface temperature below 60 C at the center of the top cover of the drive Non operating condition should no...

Страница 52: ...s 5Volts 12Volts Total W Pop Mean Std Dev Pop Mean Std Dev Idle Average 0 29 0 02 0 45 0 1 6 9 Idle ripple peak to peak 0 25 0 04 0 7 0 15 Seek peak 0 55 0 02 1 7 0 2 Seek average 1 0 33 0 02 0 7 0 1 10 1 Start up max 0 7 0 02 2 0 1 RND R W peak 0 8 0 15 0 75 0 1 RND R W average 2 0 42 0 15 0 65 0 1 9 9 Standby Sleep average 0 165 0 01 0 0045 0 001 0 9 Figure 38 Power Supply Current of DTTA 351680...

Страница 53: ...r system frame which has no electrical level difference at the four screws position and has less than 300 millivolts peak to peak level difference to the file power connector ground Figure 39 Power Supply Current of DTTA 351010 350840 350640 350430 350320 All values in Amps 5Volts 12Volts Total W Pop Mean Std Dev Pop Mean Std Dev Idle Average 0 29 0 02 0 16 0 05 3 4 Idle ripple peak to peak 0 22 0...

Страница 54: ...30 350320 Figure 41 Typical Current Wave Form of 12V at Start Up of DTTA 351010 350840 350640 350430 350320 6 5 1 2 DTTA 351680 351350 351290 Figure 42 Typical Current Wave Form of 12V at Start Up of DTTA 351680 351350 351290 46 OEM Specifications for DTTA 3xxxxx ...

Страница 55: ...6 5 1 3 DTTA 371440 371290 371010 Figure 43 Typical Current Wave Form of 12V at Start Up of DTTA 371440 371290 371010 Specification 47 ...

Страница 56: ...implementation On The Fly correction performed as a part of read channel function recovers up to 12 symbols of error in 1 sector 1 symbol is 8 bits 6 6 4 Cable Noise Interference To avoid any degradation of performance throughput or error when the interface cable is routed on top or comes in contact with the HDA assembly the drive must be grounded electrically to the system frame by four screws Th...

Страница 57: ... 5 hard disk drive form factor Figure 45 Physical Dimension and Weight DTTA 371440 DTTA 371290 DTTA 371010 DTTA 351680 DTTA 351350 DTTA 351290 DTTA 351010 DTTA 350840 DTTA 350640 DTTA 350430 DTTA 350320 Height mm 25 4 0 4 25 4 0 4 25 4 0 4 Width mm 101 6 0 4 101 6 0 4 101 6 0 4 Length mm 146 0 0 6 146 0 0 6 146 0 0 6 Weight gram 630 Max 630 Max 530 Max Specification 49 ...

Страница 58: ...Figure 46 Mechanical Dimension 50 OEM Specifications for DTTA 3xxxxx ...

Страница 59: ...6 7 3 Connector Locations Figure 47 Connector Locations Specification 51 ...

Страница 60: ...6 7 4 Hole Locations The Figure 48 on page 52 shows the outline of DTTA 3xxxxx which includes the hole locations Figure 48 Mounting Positions and the Tappings 52 OEM Specifications for DTTA 3xxxxx ...

Страница 61: ...rol Type Electrical Screw Driver should be used Mechnical Latch Type Electrical Screw Driver is not recommended because of possibility of mechanical shock higher than specification value which may cause HDD damage The system is responsible for mounting the drive securely enough to prevent from excessive motion or vibration of the drive at seek operation or spindle rotation using appropriate screws...

Страница 62: ...G RMS Overall RMS root mean square level of vertical vibration is 0 56G RMS Note The specified levels are measured at the mounting points 6 8 1 2 Swept Sine Vibration The hard disk drive will meet the criteria shown below while operating in respective conditions No errors 0 5 G 0 peak 5 300 5 Hz sine wave 0 5 oct min sweep rate with 3 minutes dwells at 2 major resonances No data loss 1 G 0 peak 5 ...

Страница 63: ...evel are applied to the drive ten pulses for each direction and for all three axes There must be a minimum of 30 seconds delay between shock pulses The input level is applied to a base plate where the drive is attached with four screws 6 8 4 Non Operating Shock The drive withstands the following half sine shock pulse No data loss with 75G 11ms No data loss with 175G 2ms The shocks are applied for ...

Страница 64: ...rive subsystem are measured under the following conditions Idle mode Powered on disks spinning track following unit ready to receive and respond to control line commands Operating mode Continuous random cylinder selection and seek operation of actuator with a delay for a time period achieving the required seek rate Ns according to the following formula Ns 0 4 Tt Tl where Ns average seek rate in se...

Страница 65: ...ne meter above the drive surface Random operation mode is simulated with 40 seek and 60 idle in time 6 9 2 2 Sound Pressure Level The hard disk drives meet the following sound pressure level Figure 53 Sound Pressure Level of DTTA 35xxxx Mode Mean Max Idle on Track 33 dBA 37 dBA Random Operation 38 dBA 41 dBA Figure 54 Sound Pressure Level of DTTA 37xxxx Mode Mean Max Idle on Track 34 dBA 38 dBA Ra...

Страница 66: ...l meet the worldwide EMC requirements listed below IBM will provide technical support to assist users in complying with the EMC requirements United States Federal Communications Commission FCC Rules and Regulations Class B Part 15 European Economic Community EEC directive number 76 889 related to the control of radio fre quency interference and the Verband Deutscher Elektrotechniker VDE requiremen...

Страница 67: ...1 6 12 5 Flammability Printed Circuit boards used in this product are made of material with a UL recognized flammability rating of V 1 or better The flammability rating is marked or etched on the board All other parts not considered electrical components are made of material with a UL recognized flammability rating of V 1 or better except minor mechanical parts 6 12 6 Secondary Circuit Protection ...

Страница 68: ...60 OEM Specifications for DTTA 3xxxxx ...

Страница 69: ...Part 2 ATA Interface Specification Copyright IBM Corp 1998 61 ...

Страница 70: ...62 OEM Specifications for DTTA 3xxxxx ...

Страница 71: ... of Information technology AT Attachment with Packet Interface Extension ATA ATAPI 4 Revision 17 dated on 30 October 1997 with certain limitations described in 8 0 Deviations From Standard on page 65 7 2 Terminology Device Device indicates DTTA 3xxxxx Host Host indicates the system that the device is attached to Copyright IBM Corp 1998 63 ...

Страница 72: ...64 OEM Specifications for DTTA 3xxxxx ...

Страница 73: ...k Power Mode Check Power Mode command returns FFh to Sector Count Register when the device is in Idle mode This command does not support 80h as the return value Hard Reset Hard reset response is not the same as that of power on reset Refer to section 10 1 Reset Response on page 73 for detail Copyright IBM Corp 1998 65 ...

Страница 74: ...66 OEM Specifications for DTTA 3xxxxx ...

Страница 75: ...ount A N 0 1 1 Sector Number Sector Number A N 0 1 1 2 LBA bits 0Ä 7 2 LBA bits 0Ä 7 A N 1 0 0 Cylinder Low Cylinder Low A N 1 0 0 2 LBA bits 8Ä15 2 LBA bits 8Ä15 A N 1 0 1 Cylinder High Cylinder High A N 1 0 1 2 LBA bits 16Ä23 2 LBA bits 16Ä23 A N 1 1 0 Device Head Device Head A N 1 1 0 2 LBA bits 24Ä27 2 LBA bits 24Ä27 A N 1 1 1 Status Command ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 76: ... At the end of the command this register is updated to reflect the current cylinder number In LBA Mode this register contains Bits 16 23 At the end of the command this register is updated to reflect the current LBA Bits 16 23 The cylinder number may be from zero to the number of cylinders minus one 9 4 Cylinder Low Register This register contains the low order bits of the starting cylinder address...

Страница 77: ...bled 9 7 Drive Address Register ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Drive Address Register ÃÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄ 7 6 5 4 3 2 1 0 HIZ ÄWTG ÄH3 ÄH2 ÄH1 ÄH0 ÄDS1 ÄDS0 ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÙ Figure 58 Drive Address Register This register contains the inverted drive select and head select addresses of the currently selected drive Bit De...

Страница 78: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register ÃÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄ 7 6 5 4 3 2 1 0 ICRCE UNC 0 IDNF 0 ABRT TK0NF AMNF ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÙ Figure 60 Error Register This register contains status from the last command executed by the device or a diagnostic code At the completion of any command except Execute Device Diagnostic the contents o...

Страница 79: ...defined otherwise on some commands These definitions are given in the command descriptions 9 12 Sector Number Register This register contains the starting sector number for any disk data access for the subsequent command The sector number is from one to the maximum number of sectors per track In LBA mode this register contains Bits 0 7 At the end of the command this register is updated to reflect ...

Страница 80: ... just before a seek begins When an error occurs this bit is not changed until the Status Register is read by the host at which time the bit again indicates the current seek complete status When the device enters into or is in Standby mode or Sleep mode this bit is set by device in spite of not spinning up SERV SRV Service SRV is set to one when the device is ready to transfer data after it release...

Страница 81: ...reset reset ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄ Aborting Host interface Ä o o Aborting Device operation Ä 1 1 Initialization of hardware o x x Internal diagnostic o x x Spinning spindle o x x Initialization of registers 2 o o o DASP handshake o o x PDIAG handshake o o o Reverting programmed parameters to default o 3 3 Ä Number of CHS set by Initialize Device Parameter Ä M...

Страница 82: ...ÄÄÄÄÄÄÄÄÄÄÄÄ Code Description ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 01h No error detected ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 02h Formatter device error ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 03h Sector buffer error ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 04h ECC circuitry error ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 05h Controller microprocessor error ÃÄÄÄÄÄÄ...

Страница 83: ...own in Figure 65 ÚÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÂÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device 1 PDIAGÄ Device 0 Error Present Asserted Passed Register ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÅÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Yes Yes Yes 01h Yes Yes No 0xh Yes No Yes 81h Yes No No 8xh No not read Yes 01h No not read No 0xh ÀÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÁÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Where x indicates the appropriate Diagnostic Code for the...

Страница 84: ...e linearly mapped with the first LBA addressed sector sector 0 being the same sector as the first logical CHS addressed sector cylinder 0 head 0 sector 1 Irrespective of the logical CHS translation mode currently in effect the LBA address of a given logical sector does not change The following is always true LBA cylinder heads_per_cylinder heads sectors_per_track sector 1 where heads_per_cylinder ...

Страница 85: ...ll be cleared and INTRQ negated by a Status reg ister read or a write to the Command register When the device is ready to continue the processing of a bus released command and BSY or DRQ is set to one i e the device is processing another command on the bus the device requests service by setting SERV to one SERV shall remain set until all commands ready for service have been serviced At command com...

Страница 86: ...es The idle command also sets the standby timer count and starts the standby timer The Standby and Standby Immediate commands move a device to standby mode immediately from the active or idle modes The standby command also sets the standby timer count The Sleep command moves a device to sleep mode The device s interface becomes inactive at the com pletion of the sleep command A reset is required t...

Страница 87: ... being used and the identity of these attributes is vendor specific and proprietary 10 6 2 Attribute values Attribute values are used to represent the relative reliability of individual performance or calibration attri butes The valid range of attribute values is from 1 to 253 decimal Higher attribute values indicate that the analysis algorithms being used by the device are predicting a lower prob...

Страница 88: ...d or a security erase unit command Device Unlocked mode The device enables all commands If a password is not set this mode is entered after power on otherwise it is entered by a security unlock or a security erase unit command Device Frozen mode The device enables all commands except those which can update the device lock function set change password The device enters this mode via a Security Free...

Страница 89: ...e end users must set the master password even if only single level password protection is required 10 7 4 Operation example 10 7 4 1 Master Password setting The system manufacturer dealer can set a new Master Password from default Master Password using the Security Set Password command without enabling the Device Lock Function 10 7 4 2 User Password setting When a User Password is set the device w...

Страница 90: ...Erase Prepare Media access NonÄmedia access command 1 command 1 Password Erase Unit ÀÄ Match Password ÄÄÄÄÄÄ N Match N Y Y Complete Reject Complete Erase Unit V V V V ÀÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Enter Device Lock function Unlock mode Disable V ÀÄÄÄÄ Normal operation All commands are available V Freeze Lock command V Enter Device Frozen mode Normal Operation except Set Password Disable Pa...

Страница 91: ...d with Master Password V Normal operation but data lost Figure 69 Password Lost 10 7 4 5 Attempt limit for SECURITY UNLOCK command The SECURITY UNLOCK command has an attempt limit The purpose of this attempt limit is to prevent that someone attempts to unlock the drive by using various passwords many times The device counts the password mismatch If the password does not match the device counts it ...

Страница 92: ...or s w retry Command aborted Executable Executable Read Verify Sector s w o retry Command aborted Executable Executable Read Verify Sector s w retry Command aborted Executable Executable Recalibrate Executable Executable Executable Security Disable Password Command aborted Executable Command aborted Security Erase Prepare Executable Executable Executable Security Erase Unit Executable Executable C...

Страница 93: ... Command aborted Executable Executable Write DMA Queued Command aborted Executable Executable Write Long w o retry Command aborted Executable Executable Write Long w retry Command aborted Executable Executable Write Multiple Command aborted Executable Executable Write Sector s w o retry Command aborted Executable Executable Write Sector s w retry Command aborted Executable Executable Write Verify ...

Страница 94: ...omer usable device size 6 292 242 432 byte 6 2GB Customer usable sector count 12 289 536 BB8600h LBA range for protected area BB8600h to C1ACFFh 1 Shipping HDDs from HDD manufacturer When the HDDs are shipped from HDD manufacturer the device has been tested to have usable capacity of 6 4GB besides flagged media defects not to be visible by system 2 Preparing HDDs at system manufacturer Special uti...

Страница 95: ... responsibility to write the data subsequently onto the disk While writing data after completed acknowledgment of a write command soft reset or hard reset does not affect its operation But power off terminates writing operation immediately and unwritten data are to be lost Soft reset Check Power Mode and Flush Cache commands during writing the cached data are executed after the completion of writi...

Страница 96: ...eration a sequence of media verification is performed automatically When the result of this verification meets the criteria this sector is reallocated Recovered read errors When a read operation for a sector failed once then recovered at the specific ERP step this sector of data is reallocated automatically A media verification sequence may be run prior to the relocation according to the pre defin...

Страница 97: ...er responding Interrupts are cleared when the host reads the Status Register issues a reset or writes to the Command Register Figure 128 on page 171 shows the device timeout values 11 1 PIO Data In Commands These commands are Identify Device Read Buffer Read Long Read Multiple Read Sectors SMART Read Attribute Values SMART Read Attribute Thresholds Execution includes the transfer of one or more 51...

Страница 98: ...will set BSY 0 ERR 1 and DRQ 1 The device will then store the error status in the Error Register and interrupt the host The registers will contain the location of the sector in error The errored location will be reported with CHS mode or LBA mode the mode is decided by mode select bit bit 6 of Device Head register on issuing the command If an Uncorrectable Data Error UNC 1 occurs the defective dat...

Страница 99: ...f data including ECC bytes via the Data Register c The device sets BSY 1 after it has received the sector d After processing the sector of data the device sets BSY 0 and interrupts the host e In response to the interrupt the host reads the Status Register f The device clears the interrupt in response to the Status Register being read The Write Multiple command transfers one block of data for each ...

Страница 100: ...mands involves no data transfer 1 The host writes any required parameters to the Features Sector Count Sector Number Cylinder and Device Head Registers 2 The host writes the command code to the Command Register 3 The device sets BSY 1 4 When the device has finished processing the command it sets BSY 0 and interrupts the host 5 In response to the interrupt the host reads the Status Register 6 The d...

Страница 101: ...and Register 4 The device sets DMARQ when it is ready to transfer any part of the data 5 Host transfers the data using the DMA transfer protocol currently in effect 6 When all of the data has been transferred the device generates an interrupt to the host 7 Host resets the slave DMA channel 8 Host reads the Status Register and optionally the Error Register 11 5 DMA Queued Commands These commands ar...

Страница 102: ...m the device 3 Bus Release If the device is not ready for data transfer REL is set a The device generates an interrupt if release interrupt is enabled b The host may issue another command or wait for service request from the device 94 OEM Specifications for DTTA 3xxxxx ...

Страница 103: ... 0 1 0 0 1 5 Read DMA Queued C7 1 1 0 0 0 1 1 1 1 Read Long retry 22 0 0 1 0 0 0 1 0 1 Read Long no retry 23 0 0 1 0 0 0 1 1 1 Read Multiple C4 1 1 0 0 0 1 0 0 3 Read Native Max LBA CYL F8 1 1 1 1 1 0 0 0 1 Read Sectors retry 20 0 0 1 0 0 0 0 0 1 Read Sectors no retry 21 0 0 1 0 0 0 0 1 3 Read Verify Sectors retry 40 0 1 0 0 0 0 0 0 3 Read Verify Sectors no retry 41 0 1 0 0 0 0 0 1 3 Recalibrate 1...

Страница 104: ... 1 0 1 1 0 0 0 0 3 Standby E2 1 1 1 0 0 0 1 0 3 Standby 96 1 0 0 1 0 1 1 0 3 Standby Immediate E0 1 1 1 0 0 0 0 0 3 Standby Immediate 94 1 0 0 1 0 1 0 0 2 Write Buffer E8 1 1 1 0 1 0 0 0 4 Write DMA retry CA 1 1 0 0 1 0 1 0 4 Write DMA no retry CB 1 1 0 0 1 0 1 1 5 Write DMA Queued CC 1 1 0 0 1 1 0 0 2 Write Long retry 32 0 0 1 1 0 0 1 0 2 Write Long no retry 33 0 0 1 1 0 0 1 1 2 Write Multiple C5...

Страница 105: ...ÄÄÄÄ ÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ Set Features Enable Write Cache EF 02 Set Transfer Mode EF 03 34 bytes of ECC apply on Read Write Long EF 44 Disable read lookÄahead feature EF 55 Enable release interrupt EF 5D Disable reverting to power on defaults EF 66 Disable write cache EF 82 Enable read lookÄahead feature EF AA 4 bytes of ECC apply on Read Wrtie Long EF BB Enable reverting to power on defaults EF CC...

Страница 106: ...the Option Bit of the Sector Count Register should be specified This bit is used by Set Max LBA CYL command V Valid Indicates that the bit is part of an output parameter and should be specified x Indicates that the hex character is not used Indicates that the bit is not used Input Registers 0 Indicates that the bit is always set to 0 1 Indicates that the bit is always set to 1 H Head number Indica...

Страница 107: ...inder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 1 0 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 108: ...Ä Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 Ä Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 0 0 1 0 0 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 109: ...Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 1 1 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 110: ... Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V V V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ Figure 77 Format Track Command 50h The Format Track...

Страница 111: ...ecifies current LBA address bits 8 15 Low 16 23 High H In LBA mode this register specifies current LBA address bits 24 27 L 1 Error The Error Register An Abort error ABT 1 will be returned under the following condition No spare data sector to be assigned In LBA mode this command formats a single logical track including the specified LBA Command Descriptions 103 ...

Страница 112: ...ÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 1 1 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄ...

Страница 113: ...s in default translate mode 02 0 Number of removable cylinders 03 00xxH Number of heads in default translate mode 04 0 Reserved 05 0 Reserved 06 003FH Number of sectors per track in default translate mode 07 0000H Number of bytes of sector gap 08 0000H Number of bytes in sync field 09 0000H Reserved 10Ä19 XXXX Serial number in ASCII 0 not specified 20 0003H Controller type 0003 dual ported multipl...

Страница 114: ...eads 56 xxxxH Number of current sectors per track 57Ä58 xxxxH Current capacity in sectors Word 57 specifies the low word of the capacity 59 0xxxH Current Multiple setting bit assignments 15Ä 9 0 Reserved 8 1 Multiple Sector Setting is Valid 7Ä 0 xxh Current setting for number of sectors 60Ä61 xxxxH Total Number of User Addressable Sectors Word 60 specifies the low word of the number 62 xx07H Singl...

Страница 115: ...r 15Ä 0 11 ATA ATAPIÄ4 X3T13 1153D revision 17 82 74EBH Command set supported 15 0 Reserved 14 1 NOP command 13 1 READ BUFFER command 12 1 WRITE BUFFER command 11 0 Reserved 10 1 Host Protected Area feature set 9 0 DEVICE RESET command 8 0 SERVICE interrupt 7 1 RELEASE interrupt 6 1 LOOK AHEAD 5 1 WRITE CACHE 4 0 PACKET Command feature set 3 1 Power management feature set 2 0 Removable feature set...

Страница 116: ...ture set 1 READ WRITE DMA QUEUED 0 DOWNLOAD MICROCODE command 87 4000H Command set feature default 15Ä14 01 Word 87 is valid 13Ä 0 0 Reserved 88 0x07H Ultra DMA transfer modes 15Ä 8 0x Current active Ultra DMA transfer mode 15Ä11 Reserved 0 10 Mode 2 1 Active 0 Not Active 9 Mode 1 1 Active 0 Not Active 8 Mode 0 1 Active 0 Not Active 7Ä 0 07 Ultra DMA transfer mode supported 7Ä 3 Reserved 0 2 Mode ...

Страница 117: ...ed 3 Freeze 1 Frozen 2 Lock 1 Locked 1 Enable Disable 1 Enable 0 Capability 1 Support 129 xxxxH Current Set Feature Option Bit assignments 15Ä 4 Reserved 3 Auto reassign 1 Enable 2 Reverting 1 Enable 1 Read LookÄahead 1 Enable 0 Write Cache 1 Enable 130Ä159 xxxxH Reserved 160Ä255 0000H Reserved ÀÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Figure 83 Identify device...

Страница 118: ...ÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 0 1 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅ...

Страница 119: ...ed the drive will enter Standby mode automatically if the timeout interval expires with no drive access from the host The timeout interval will be reinitialized if there is a drive access before the timeout interval expires Command Descriptions 111 ...

Страница 120: ...Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 0 0 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 121: ...ÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 0 0 V 0 0 0 V 0...

Страница 122: ...High Ä Ä Ä Ä Ä Ä Ä Ä Cylinder High Initial value ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Initial value ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 0 0 0 0 0 0 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄ...

Страница 123: ...Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 1 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Regis...

Страница 124: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ V 0 0 V 0 V 0 V 0 V 0 V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄ...

Страница 125: ...erred This will be zero unless an unre coverable error occurs Sector Number The sector number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the sector to be transferred L 0 In LBA m...

Страница 126: ... 1 1 0 0 0 1 1 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF SRV DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄ...

Страница 127: ...n the device performs a bus release This bit is set to one when the device is ready to transfer data Input Parameters From The Device On Command Complete Sector Count bits 7 3 Tag contain the Tag of the completed command bit 2 REL is cleared to zero bit 1 I O is set to one bit 0 C D is set to one Sector Number Cylinder High Low H sector address of unrecoverable error applicable only when unrecov e...

Страница 128: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 V 0 V 0 V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁ...

Страница 129: ...inder High Low The cylinder number of the transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 It should be noted that the device internally uses 34 bytes of ECC data on all data written or read from the disk The 4 byte mode of operation is pro...

Страница 130: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 V 0 V 0 V 0 V 0 V 0 V Ä ...

Страница 131: ...of the last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 Command Descriptions 123 ...

Страница 132: ...ice Head 1 L 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä H H H H ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 1 1 0 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7...

Страница 133: ...See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄ...

Страница 134: ...last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 126 OEM Specifications for DTTA 3xxxxx ...

Страница 135: ...ÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 V 0 V 0 V 0...

Страница 136: ...ast transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 128 OEM Specifications for DTTA 3xxxxx ...

Страница 137: ...ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 0 0 0 1 Ä Ä Ä Ä Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄ...

Страница 138: ...ÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 0 0 V 0 0 0 V 0 V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ Figure 97 Security Disable Password Command F6h The Security Disable Password command disables the security mode f...

Страница 139: ... Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 1 0 0 1 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 140: ...ÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V 0 V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄ...

Страница 141: ...ated The secu rity erase prepare command should be completed immediately prior to the Security Erase Unit command If the device receives a Security Erase Unit command without a prior Security Erase Prepare command the device aborts the security erase unit command This command disables the security mode feature device lock function however the master password is still stored internally within the d...

Страница 142: ...ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 1 0 1 0 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄ...

Страница 143: ...Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 1 0 0 0 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 AB...

Страница 144: ...sword The text of the password all 32 bytes are always significant The setting of the Identifier and Security level bits interact as follows Identifier User Security level High The password supplied with the command will be saved as the new user password The security mode feature lock function will be enabled from the next power on The file may then be unlocked by either the user password or the p...

Страница 145: ...ÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 V 0 0 0 V 0 0 0 V 0 Ä Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ Figure 105...

Страница 146: ...nlock Information Identifier Zero indicates that device regards Password as User Password One indicates that device regards Password as Master Password The user can detect if the attempt to unlock the device has failed due to a mismatched password as this is the only reason that an abort error will be returned by the file AFTER the password information has been sent to the device If an abort error...

Страница 147: ...ÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 0 1 1 1 Ä Ä Ä Ä Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄ...

Страница 148: ...Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head Ä Ä Ä D Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 0 1 0 0 0 1 0 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Figure 108 Service Command A2h The Service command is used to provide data transfer and or status of a command that was previously bus released Output Parameters To The ...

Страница 149: ...ÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 1 1 1 1 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ C...

Страница 150: ...000 nnn nnn 000 001 010 Note 2 If the number of auto reassigned sector reaches the device s reassignment capacity the write cache function will be automatically disabled Although the device still accepts the Set Features command with Feature register 02h without error but the write cache function will remains disabled For current write cache function status please refer to Identify Device Informat...

Страница 151: ...ÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 0 0 V 0 0 0 V 0 Ä Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ Figur...

Страница 152: ...ameters From The Device Sector Number In LBA mode this register contains max LBA bits 0 7 which is set L 1 In CHS mode this register contains max sector number L 0 Cylinder High Low In LBA mode this register contains max LBA bits 8 15 Low 16 23 High which is set L 1 In CHS mode this register contains max cylinder number which is set L 0 H In LBA mode this register contains max LBA bits 24 27 which...

Страница 153: ...Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 0 0 0 1 1 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 ...

Страница 154: ...ÄÄÄÄÄÄÄÄÄÄ Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 1 1 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 155: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 0 0...

Страница 156: ...f F1h written by the host into the device s Sector Count Register before issuing the SMART Enable Disable Attribute Autosave subcommand will cause this feature to be enabled Any other non zero value written by the host into this register before issuing the SMART Enable Disable Attribute Autosave subcommand will not change the current Autosave status but the device will respond with the error code ...

Страница 157: ...receipt of the SMART Disable Operations subcommand from the host the device disables S M A R T capabilities and functions and then saves any updated Attribute Values to the Attribute Data sector After receipt of the device of the SMART Disable Operations subcommand from the host all other S M A R T subcommands with the exception of SMART Enable Operations are disabled and invalid and will be abort...

Страница 158: ...ts required for 1 16Bh 1 01h offÄline data collection ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ Total time in seconds to 2 16Ch 1 2 complete next segment ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ Current segment pointer 1 16Eh 1 2 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ OffÄline data collection capability 1 16Fh 1 0...

Страница 159: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ 01h minimum value ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ 64h initial value for all attributes prior to any data collection ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ FDh maximum value ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ...

Страница 160: ...d bits Always 0 ÀÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Figure 116 Status Flag Definitions 12 31 2 2 3 Normalized Values The device will perform conversion of the raw Attribute Values to trans form them into normalized values which the host can then compare with the Threshold values A Threshold is the excursion limit for a normalized Attribute Value In norma...

Страница 161: ... indicating the next segment to execute as an off line data collection activity This varies from 00h to the total number of segments The current segment pointer will be 00h if the off line data collection has not been started If the off line data collection is aborted by a command or an error i e the status is 05h or 06h this byte will point to the aborted segment If the all segments complete this...

Страница 162: ...ÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ 30th Attribute Threshold 12 15Eh 1 2 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ Reserved 18 16Ah 3 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ Vendor specific 131 17Ch 3 ÃÄÄÄÄÄÄÄ...

Страница 163: ...hreshold value ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ FFh Ä always failing threshold value to be used for code test purposes ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ Reserved 00h 10 02h binary ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄ Total Bytes 12 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 164: ...ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ The device is unable to read its Attribute Values or 10h Attribute Thresholds data structure 51h or 40h ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ The device is unable to write to its Attribute Values 51h 10h data structure or 01h ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ The Data Structrue Revision Numbe...

Страница 165: ...ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 0 1 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄ...

Страница 166: ... 255 21 minutes 15 seconds When the automatic power down sequence is enabled the drive will enter Standby mode automatically if the timeout interval expires with no drive access from the host The timeout interval will be reinitialized if there is a drive access before the timeout interval expires 158 OEM Specifications for DTTA 3xxxxx ...

Страница 167: ...ÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 0 0 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Registe...

Страница 168: ...Ä Ä Ä Cylinder High Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Device Head 1 Ä 1 D Ä Ä Ä Ä Device Head Ä Ä Ä Ä Ä Ä Ä Ä ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Command 1 1 1 0 1 0 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ...

Страница 169: ...ÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V V V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄ...

Страница 170: ...requested sectors not transferred This will be zero unless an unre coverable error occurs Sector Number The sector number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last tran...

Страница 171: ...ommand 1 1 0 0 1 1 0 0 Status See Below ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF SRV DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ Ã...

Страница 172: ...evice performs a bus release This bit is set to one when the device is ready to transfer data Input Parameters From The Device On Command Complete Sector Count bits 7 3 Tag contain the Tag of the completed command bit 2 REL is cleared to zero bit 1 I O is set to one bit 0 C D is set to one Sector Number Cylinder High Low H sector address of unrecoverable error applicable only when unrecov erable e...

Страница 173: ...ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V V V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ ÀÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÙ Figure 125 Writ...

Страница 174: ...bits 8 15 Low 16 23 High L 1 H The head number of the sector to be transferred L 0 In LBA mode this register contains current LBA bits 24 27 L 1 The file internally uses 34 bytes of ECC on all data read or writes The 4 byte mode of operation is pro vided via an emulation technique As a consequence of this emulation it is recommended that 34 byte ECC mode is used for all tests to confirm the operat...

Страница 175: ...ÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V...

Страница 176: ...last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 168 OEM Specifications for DTTA 3xxxxx ...

Страница 177: ... ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Error Register Status Register ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ ÃÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄ 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ ÃÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄÅÄÄÄ 0 0 0 V 0 V 0 0 0 V V V Ä 0 Ä V ÀÄÄÄÁÄÄÄÁÄÄ...

Страница 178: ...last transferred sector L 0 In LBA mode this register contains current LBA bits 0 7 L 1 Cylinder High Low The cylinder number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 8 15 Low 16 23 High L 1 H The head number of the last transferred sector L 0 In LBA mode this register contains current LBA bits 24 27 L 1 170 OEM Specifications for DTTA 3xxxxx ...

Страница 179: ...c Hard Reset Asserted BSY 0 and RDY 1 ÃÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ Data In Device Busy After OUT to Command Status Register 400 ns Command Command Code Out Register BSY 1 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ Interrupt DRQ For Status Register Status Register 30 sec Data Transfer In BSY 1 BSY 0 and DRQ 1 Interrupt Ã...

Страница 180: ...ÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ DMA Data Device Busy after Out to Command Status Register 400 ns Transfer Command Code Out Register BSY 1 Command ÀÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÙ Figure 129 Timeout Values Continued Command category is referred to 11 0 Command Protocol on page 89 The abbreviations ns us ms and ...

Страница 181: ...bsolete 33h WRITE LONG w o retry Yes Obsolete 34hÄ3Bh Reserved Reserved Reserved 3Ch WRITE VERIFY No Obsolete 3DhÄ3Fh Reserved Reserved Reserved 40h READ VERIFY SECTOR S w retry Yes Mandatory 41h READ VERIFY SECTOR S w o retry Yes Mandatory 42hÄ4Fh Reserved Reserved Reserved 50h FORMAT TRACK Yes Obsolete 51hÄ5Fh Reserved Reserved Reserved 60hÄ6Fh Reserved Reserved Reserved 70h SEEK Yes Mandatory 7...

Страница 182: ...l Ä 2 E3h IDLE 1 Yes Optional Ä 2 E4h READ BUFFER Yes Optional E5h CHECK POWER MODE 1 Yes Optional Ä 2 E6h SLEEP 1 Yes Optional Ä 2 E7h FLUSH CACHE Yes Optional E8h WRITE BUFFER Yes Optional E9h WRITE SAME No Retired EAhÄEBh Reserved Reserved Reserved ECh IDENTIFY DEVICE Yes Mandatory EDh MEDIA EJECT No Optional Ä 5 EEh IDENTIFY DEVICE DMA No Obsolete EFh SET FEATURES Yes Optional F0h Vendor speci...

Страница 183: ...try No Obsolete 44h Set vendor specific bytes ECC Yes Obsolete 54h Set cache segments No Obsolete 55h Disable read lookÄahead feature Yes Optional 5Dh Enable release interrupt Yes Optional 5Eh Enable SERVICE interrupt No Optional 66h Disable reverting to power on defaults Yes Optional 77h Disable ECC No Obsolete 81h Disable 8 bit data transfers No Retired 82h Disable write cache Yes Mandatory 84h ...

Страница 184: ...176 OEM Specifications for DTTA 3xxxxx ...

Страница 185: ...sable Password F6h 130 Security Erase Prepare F3h 131 Security Erase Unit F4h 132 Security Freeze Lock F5h 134 Security Set Password F1h 135 Security Unlock F2h 137 Seek 7xh 139 Service A2h 140 Set Features EFh 141 Set Max LBA CYL F9h 143 Set Multiple C6h 145 Sleep E6h 99h 146 Standby E2h 96h 157 Standby Immediate E0h 94h 159 Command continued Write Buffer E8h 160 Write DMA CAh CBh 161 Write DMA Q...

Страница 186: ...1 Sector Number Register 71 Status Register 71 Register Initialization 74 Reset Diagnostic and Reset considerations 74 Register Initialization 74 RST 69 S S M A R T Function 79 Attribute thresholds 79 Attribute values 79 Attributes 79 S M A R T commands 79 Threshold exceeded condition 79 S M A R T Function Set 147 Sector Addressing Mode 75 LBA Addressing Mode 76 Logical CHS Addressing Mode 75 Secu...

Страница 187: ...imeout Parameter 110 157 Timeout Values 171 TK0NF 70 U UNC 70 V V 98 W Write Buffer 90 160 Write Cache 87 Write DMA 92 161 Write DMA Queued 93 163 Write Long 90 165 Write Multiple 90 167 Write Sectors 90 169 WTG 69 X x 98 Index 179 ...

Страница 188: ...Published in Japan S00K 0286 02 ...

Отзывы: