10.8
Protected Area Function (Vendor Specific)
Protected Area Function is to provide the 'protected area' which can not be accessed via conventional
method. This 'protected area' is used to contain critical system data such as BIOS or system management
information. The contents of entire system main memory may also be dumped into 'protected area' to
resume after system power off.
The LBA/CYL changed by following command affects the Identify Device Information.
Two vendor specific commands are defined for this function.
Read Native Max LBA/CYL
('F8'h)
Set Max LBA/CYL
('F9'h)
10.8.1 Example for operation (In LBA mode)
Assumptions :
For better understanding, following example uses actual values for LBA, size, etc. Since it is just an example,
those value could be different.
Device characteristics
Capacity (native)
: 536,870,912 byte
(536MB)
Max LBA
(native)
:
1,048,575 (0FFFFFh)
Required size for protected area
:
8,388,608 byte
Required blocks for protected area
:
16,384 (004000h)
Customer usable device size
: 528,482,304 byte
(528MB)
Customer usable sector count
:
1,032,192 (0FC000h)
LBA range for protected area
: 0FC000h to 0FFFFFh
1. Shipping HDDs from H D D manufacturer
When the HDDs are shipped from H D D manufacturer,the device has been tested to have capacity of
536MB,flagged the media defects not to be visible by system.
2. Preparing HDDs at system manufacturer
Special utility software is required to define the size of protected area and store the data into it. The
sequence is :
|
Issue Read Native Max LBA/CYL command to get the real device max of LBA/CYL. Returned
|
value shows that native device Max LBA is 0 F F F F F h regardless to the current setting.
|
Make entire device be accessible including the protected area by setting device Max LBA as
|
0 F F F F F h via Set Max LBA/CYL command. The option could be either nonvolatile or volatile.
Test the sectors for protected are (LBA > = 0FC000h) if required.
Write information data such as BIOS code within the protected area.
|
Change maximum LBA using Set Max LBA/CYL command to 0 F B F F F h with nonvolatile option.
From this point, the protected area cannot be accessed till next Set Max LBA/CYL command is
issued. Any BIOSes, device drivers, or application software access the H D D as if that is the 528MB
device because the device acts exactly same as real 528MB device does.
3. Conventional usage without system software support
General Operation Descriptions
71
Содержание DTNA-22160 - Travelstar 2.1 GB Hard Drive
Страница 2: ......
Страница 11: ...Figure 2 Breathing hole caution of DTNA 21800 22160 General 3...
Страница 12: ...4 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 14: ...6 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 15: ...Part 1 Functional Specification Copyright IBM Corp 1997 7...
Страница 16: ...8 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 26: ...18 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 40: ...32 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 51: ...Part 2 ATA Interface Specification Copyright IBM Corp 1997 43...
Страница 52: ...44 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 54: ...46 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 56: ...48 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 82: ...74 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 88: ...80 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 163: ...Command Descriptions 155...
Страница 164: ...156 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 167: ...Timings 159...
Страница 168: ...160 OEM Specifications of DTNA 2xxxx 2 5 inch HDD...
Страница 176: ...IBML Published in Japan S46H 5175 03...