background image

68 Pin Auxiliary Connector

12

Pin # 11

9

7

5

3

1

10

8

6

4

2

+5V

ID3 ID2 ID1 ID0

SCSI Address

Enable Active Termination

(Unused for differential models)

Write Protect

Unused

Ground

Auto Spin Start

External Activity LED

Reserved

SCSI ID (Address) Pins

Note: In the address determination

tables, “off” means jumper is not
in place and “on” means jumper
is in place.

Bit 3 Bit 2 Bit 1

Bit 0

Address

off off off off 

0

off off off on 

1

off off on off 

2

off off on on 

3

off on off off 

4

off on off on 

5

off on on off 

6

off on on on 

7

on off off off 

8

on off off on 

9

on off on off 

10

on off on on 

11

on on off off 

12

on on off on 

13

on on on off 

14

on on on on 

15

Address Determination
68 and 80 pin models

Bit 2

Bit 1

Bit 0

Address

off off  off 

0

off off  on 

1

off on  off 

2

off on  on 

3

on off  off 

4

on off  on 

5

on on  off 

6

on 

on on  7

Address Determination of 50 pin
models 

Auto Start and Delay Pins

The Auto Start and Auto Start Delay
pins control when and how the drive
can spin up and come ready.
When configured for Auto-Startup, the
motor spins up after power is applied
without the need of a SCSI Start Unit
command. For no Auto-Start, a SCSI
Start Unit command is required to make
the drive spin and be ready for  media
access operations. When in Auto-Start
mode, the drive will delay its start time
by a period of time multiplied by its own
SCSI address.

Pins (50 and 68

Drive

interface pin models)

Behaviour

Auto

Auto

Auto Delay(sec)

Start Delay Start

Start

Multiplier

off

off

No

N/A

off

on

Yes

0

on

off

Yes

10

on

on

Yes

4

Auto-Startup Modes selectable by
Auto-Start/Delay Pin Combinations.

Pins (80 interface

Drive

pin model)

Behaviour

Auto

Auto

Auto Delay(sec)

Start Delay Start

Start

Multiplier

off

off

Yes

0

off

on

No

N/A

on

off

Yes

10

on

on

No

N/A

Auto-Startup Modes selectable by
Auto-Start/Delay Pin Combinations.

PACKAGING: The drive must
be protected against
electrostatic Discharge
especially 

when 

being handled.

The safest way to avoid

damage is to put the drive in an anti
static bag before ESD wrist straps etc.
are removed.

Drives should only be shipped in
approved containers, severe damage
can be caused to the drive if the
packaging does not adequately protect
against the shock levels induced when
a box is dropped. Consult your IBM
marketing representative if you do not
have an approved shipping container.

External Activity (LED) Pins

The LED pins can be used to drive an
external  Light Emitting Diode. Please
refer to the LED pin section of the
Ultrastar Interface Specification for a
detailed functional description of this
pin, which is controlled by Mode Select
(Page  0).  Up to 33mA ( 5%) of TTL
level LED drive capability is provided.
Current limiting for the LED is provided
on the electronics card. The LED Anode
may be tied to the + 5V source provided
on pin 18 of the Front Option Jumper
Block, pin 11 of the Auxiliary connector
on the 68 pin Unitised connector or the
5V power source on the 80 pin  SCA
model.  The  LED Cathode is then
connected to the EXTERNAL ACTIVITY
Pin to complete the circuit.

Note: 68 pin and 80 pin SCA  SCSI

models have two sets of pins, a
set on the front and a set on the
back, that are connected to the
same LED driver circuit. The
combined drive capability is
stated above.

Write Protect Pin

If the Write Protect pin is jumpered to
ground, the drive will prohibit SCSI
commands that alter the customer data
area portion of the media from being
performed. The state of this pin is
monitored on a per command basis.
See the Ultrastar 9LP & 18XP interface
specification for functional details.

Содержание DGHS-318220

Страница 1: ...d multitasking applications M M Low command overhead M M Read ahead caching M M Improved data throughput M M ECC on the fly EOTF M M Industry standard mounting M M Ease of installation M M Predictive Failure Analysis S M A R T Compliant M M High reliability and availability IBM OEM has introduced a new range of drives intended for advanced storage applications which demand fast access to large amo...

Страница 2: ... 2 4 6 8 20 22 24 26 28 30 32 Enable Active Termination 5V 2 SCSI Address Not Used Blank Ground External Activity LED Write Protect Auto Start Delay Disable Sync Negotiations Disable SCSI Parity Disable Unit Attention Reserved Reserved Reserved Auto Start 50 Pin Single Ended Front Option Block and TermPower Block Reserved Reserved Ground Ground Ground Termination Power Enable 1 3 5 7 11 13 15 17 1...

Страница 3: ... Delay Start Start Multiplier off off Yes 0 off on No N A on off Yes 10 on on No N A Auto Startup Modes selectable by Auto Start Delay Pin Combinations PACKAGING The drive must be protected against electrostatic Discharge especially when being handled The safest way to avoid damage is to put the drive in an anti static bag before ESD wrist straps etc are removed Drives should only be shipped in ap...

Страница 4: ...apacity blocks block bytes drive 512 18 351 959 040 35 843 670 514 18 283 057 100 35 570 150 520 18 132 478 000 34 870 150 522 18 102 432 780 34 678 990 524 18 098 346 920 34 538 830 528 18 177 133 920 34 426 390 536 18 242 658 160 34 034 810 688 18 760 955 040 27 268 830 732 18 832 742 280 25 727 790 User bytes logical block 512 to 732 Mode Select Options Certain parameters are alterable using th...

Страница 5: ...hment 80 pin SCA 2 models use an AMP connector PN 5 917593 9 that is compatible with the specification of Single Connector Attachment for Small SCSI Disk Drives SFF 8046 It can transfer data in both 8 bit Narrow and 16 bit wide modes Note The SCA 2 connector is not mechanically compatible with the 50 pin A connector or the 68 pin P connector as defined in the ANSI SCSI standard This connector is i...

Страница 6: ... power SCSI Bus Termination Power Short Circuit Protection The ANSI SCSI specification recommends for devices that optionally supply TERMPWR to include current limited protection for accidental short circuits It also recommends that the maximum current available for TERMPWR should not exceed 2 Amps UL has a different requirement that they call the 8 Amp rule This rule states that when a power sour...

Страница 7: ... if the unpackaged 9 11GB drive is not subjected to an 2 millisecond half sine wave shock greater than 150Gs applied to all three axis one direction at a time Additionally no damage will occur if the unpackaged 18 22GB drive is not subjected to a 2 millisecond half sine wave shock greater than 140Gs applied to all three axis one direction at a time For the 1 0 models no degradation in A weighted i...

Страница 8: ...temperature must not be exceeded at the worst case drive and system operating conditions with the drive randomly seeking reading and writing Reliability temperatures must not be exceeded at the nominal drive and system operating conditions with the drive randomly seeking reading and writing Maximum and Reliable Operating Temperature Limits Maximum Optimum Disk Enclosure Top 149o F 65o C 122o F 50o...

Страница 9: ... trademark of AMP Incorporated Other company product and service names may be trademarks or service marks of others Produced by European SIT Lab International Business Machines Corporation 1997 This data sheet is not a substitute for the full production specification which should be used when detailed information is required Product Description data represents IBM s design objectives and is provid...

Отзывы: