background image

enable

 

the

 

I/O

 

module

 

ports,

 

external

 

management

 

of

 

I/O

 

module

 

ports,

 

other

 

I/O

 

module

 

settings;

 

and

 

start

 

the

 

configuration

 

and

 

management

 

firmware

 

that

 

is

 

in

 

an

 

I/O

 

module.

 

Note:

  

The

 

initial

 

factory-defined

 

user

 

ID

 

and

 

password

 

for

 

the

 

I/O

 

module

 

firmware

 

are:

 

v

   

User

 

ID:

 

USERID

 

(all

 

capital

 

letters)

 

v

   

Password:

 

PASSW0RD

 

(note

 

the

 

zero,

 

not

 

O,

 

in

 

PASSW0RD)

See

 

the

 

Installation

 

and

 

User’s

 

Guide

 

for

 

your

 

BladeCenter

 

unit

 

for

 

more

 

information

 

about

 

basic

 

I/O

 

module

 

configuration.

 

See

 

the

 

documentation

 

that

 

comes

 

with

 

the

 

I/O

 

module

 

for

 

details

 

about

 

the

 

configuration

 

and

 

management

 

firmware

 

for

 

the

 

I/O

 

module.

 

Documentation

 

for

 

some

 

I/O

 

modules

 

is

 

on

 

the

 

IBM

 

BladeCenter

 

Documentation

 

CD.

 

Firmware

 

Update

    

Select

 

the

 

Firmware

 

Update

 

choice

 

to

 

update

 

the

 

firmware

 

in

 

a

 

I/O

 

module.

 

Select

 

the

 

target

 

I/O

 

module

 

and

 

the

 

firmware

 

file

 

to

 

use

 

for

 

the

 

update;

 

then,

 

click

 

Update

.

 

You

 

can

 

obtain

 

the

 

firmware

 

files

 

from

 

the

 

IBM

 

Support

 

Web

 

site

 

at

 

http://www.ibm.com/pc/support/.

 

MM

 

Control

 

Select

 

the

 

choices

 

in

 

the

 

MM

 

Control

 

section

 

to

 

view

 

and

 

change

 

the

 

settings

 

or

 

configuration

 

on

 

the

 

management

 

module

 

that

 

you

 

are

 

logged

 

in

 

to

 

(the

 

primary

 

management

 

module)

 

through

 

this

 

management-module

 

Web

 

interface

 

session.

 

If

 

your

 

BladeCenter

 

unit

 

has

 

redundant

 

management

 

modules,

 

the

 

configuration

 

settings

 

of

 

the

 

primary

 

management

 

module

 

are

 

automatically

 

transferred

 

to

 

the

 

secondary

 

management

 

module.

 

Management

 

module

 

configuration

 

includes

 

the

 

following

 

items:

 

v

   

The

 

name

 

of

 

the

 

management

 

module

 

v

   

Up

 

to

 

12

 

login

 

profiles

 

for

 

logging

 

in

 

to

 

the

 

management

 

module

 

v

   

Ports

 

used

 

by

 

the

 

management

 

module

 

v

   

How

 

alerts

 

are

 

handled

 

v

   

The

 

management

 

module

 

Ethernet

 

connections

 

for

 

remote

 

console

 

and

 

for

 

communicating

 

with

 

the

 

I/O

 

modules

 

v

   

Settings

 

for

 

the

 

SNMP,

 

DNS,

 

SMTP,

 

and

 

LDAP

 

protocols

 

v

   

Settings

 

for

 

secure

 

socket

 

layer

 

(SSL)

 

and

 

secure

 

shell

 

(SSH)

 

security

 

This

 

also

 

includes

 

performing

 

the

 

following

 

tasks:

 

v

   

Backing

 

up

 

and

 

restoring

 

the

 

management-module

 

configuration

 

v

   

Updating

 

the

 

management-module

 

firmware

 

v

   

Restoring

 

the

 

default

 

configuration

 

v

   

Restarting

 

the

 

management

 

module

 

v

   

Switching

 

from

 

the

 

current

 

active

 

management

 

module

 

to

 

the

 

redundant

 

management

 

module

  

26

 

BladeCenter

 

Management

 

Module:

 

User’s

 

Guide

Содержание BladeCenter Management Module

Страница 1: ...BladeCenter Management Module User s Guide ERserver...

Страница 2: ......

Страница 3: ...BladeCenter Management Module User s Guide ERserver...

Страница 4: ...al information in Appendix B Notices on page 59 Fourth Edition February 2004 Copyright International Business Machines Corporation 2004 All rights reserved US Government Users Restricted Rights Use du...

Страница 5: ...ule Web interface 11 User authority 11 Starting the management module Web interface 12 Management module Web interface options 14 Monitors 14 System Status 14 Event Log 16 LEDs 17 Hardware VPD 18 Firm...

Страница 6: ...odifying your ASM configuration 55 Appendix A Getting help and technical assistance 57 Before you call 57 Using the documentation 57 Getting help and information from the World Wide Web 58 Software se...

Страница 7: ...alleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Страница 8: ...disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems b...

Страница 9: ...r cords associated with accessories sold with this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands a...

Страница 10: ...viii BladeCenter Management Module User s Guide...

Страница 11: ...e redundant management module The latest level of management module firmware is available at the IBM Support Web site at http www ibm com pc support The management module functions as a service proces...

Страница 12: ...this indicator is lit the system error LED on each of the BladeCenter system LED panels is also lit v Ethernet link When this green LED is lit there is an active connection through the port to the ne...

Страница 13: ...net Video Mouse Keyboard Note There is no internal connections between the input output connectors on the management modules when two are installed in the BladeCenter unit See the IBM BladeCenter Mana...

Страница 14: ...e connection to the network management station on the network Use this port to establish connections with the remote management and remote console features of the BladeCenter unit The network manageme...

Страница 15: ...anagement station to connect to the management module to configure the port completely and to configure the rest of the BladeCenter unit v The IP address for the internal Ethernet port on the manageme...

Страница 16: ...rs v Accessing the I O modules to configure them v Changing the drive startup sequence for a blade server v Setting the date and time v Using a remote console for the blade servers v Changing ownershi...

Страница 17: ...thernet connector on the management module Connect the other end of the Ethernet cable to the network 2 Check the Ethernet LEDs to ensure that the network connection is working v When the green Ethern...

Страница 18: ...ment module then use your Web browser to connect to the management module see Starting the management module Web interface on page 12 for more information In the browser Address field specify the IP a...

Страница 19: ...y provide connectivity from the IBM Director server to the BladeCenter management module Ethernet port To establish connectivity the management module attempts to use DHCP to acquire its initial IP ad...

Страница 20: ...10 BladeCenter Management Module User s Guide...

Страница 21: ...face windows and the authority levels that are required to change information in these windows The windows and authorities listed in this table only apply to changing the information in a window or ex...

Страница 22: ...Update v v Configuration v v v Serial over LAN v v v I O Module Tasks Power Restart v v Management v v v Firmware Update v v MM Control General Settings v v v Login Profiles v v v Alerts v v v Port As...

Страница 23: ...all capital letters v Password PASSW0RD note the zero not O in PASSW0RD 3 Follow the instructions that appear on the screen Be sure to set the timeout value you want for your Web session The BladeCen...

Страница 24: ...in the sections that follow Online help is provided for the management module Web interface Click the help icon next to a section or choice to display additional information about this item Monitors...

Страница 25: ...ttings in the blade server BIOS code v Local Control An indication of whether the following options are enabled Local power control Local keyboard video and mouse switching Local CD ROM drive diskette...

Страница 26: ...rent speed of the blower module as a percentage of the maximum revolutions per minute RPMs The blower speed varies with the thermal load An entry of Offline indicates that the blower is not functionin...

Страница 27: ...LED and turn on turn off or blink the location LED on the BladeCenter unit and the blade servers v Front Panel LEDs The state of the following LEDs on the BladeCenter system LED panel You can change...

Страница 28: ...the log of modules inserted or removed from the BladeCenter unit Firmware VPD Select the Firmware VPD choice to view the vital product data VPD for the firmware in all blade servers I O modules and ma...

Страница 29: ...v Turn on or turn off the selected blade server set the power state on or off v Enable or disable local power control When local power control is enabled a local user can turn on or turn off the blad...

Страница 30: ...Select the check boxes in the Select column for one or more On Demand blade servers that have a Standby status then click the Activate Standby Blade Servers link to activate the selected blade server...

Страница 31: ...media tray Mount a disk drive or disk image from the computer that is acting as the remote console on to a blade server The mounted disk drive or disk image will appear as a USB device attached to the...

Страница 32: ...following commands init 3 Switch to text mode if necessary rmmod mousedev Unload the mouse device driver b Add the following statement to xinitrc in the user s home directory xset m 1 1 Turn off mous...

Страница 33: ...selection of hard disk drives depends on the hard disk drives that are installed in your blade server CD ROM Diskette Network PXE Attempt a PXE DHCP network startup the next time the selected blade s...

Страница 34: ...y for the BladeCenter unit Enabling or disabling SOL globally does not effect the SOL session status for each blade server SOL must be enabled both globally for the BladeCenter unit and individually f...

Страница 35: ...f I O modules such as pass thru modules Power Restart Select the Power Restart choice to display the power status of the I O modules and perform the following actions v Turn on or turn off an I O modu...

Страница 36: ...trol section to view and change the settings or configuration on the management module that you are logged in to the primary management module through this management module Web interface session If y...

Страница 37: ...ettings are used during SNMP and SMTP configuration See Configuring SNMP on page 35 and Configuring SMTP on page 37 for additional information Login Profiles Select the Login Profiles choice to config...

Страница 38: ...write and execute access to all management module functions Users with Read Only authority can access all management module functions for viewing only Attention If you change the default login profil...

Страница 39: ...ients for IBM Director over LAN the remote alert recipient must be an IBM Director enabled server Port Assignments Select the Port Assignments choice to configure some of the ports used by the managem...

Страница 40: ...mber fixed Description 25 Port used for TCP e mail alerts 53 Port used for the UDP Domain Name Server DNS resolver 68 Port used for DHCP client connection using UDP 427 Port used for the UDP Service L...

Страница 41: ...external Ethernet port the I O module internal network interface and the management module internal and external interfaces must be on the same subnet v External Network Interface eth0 This is the int...

Страница 42: ...warning messages generated by the TCP IP code running on the management module and might be used by your service representative for advanced troubleshooting The log displays the most recent entries fi...

Страница 43: ...between self signed certificates and certificates provided by a certificate authority CA You can also enable or disable the default SSH and generate and manage the SSH server key Some of the Security...

Страница 44: ...ate will automatically be applied to both management modules Click Browse to locate the firmware file you want then click Update Management module firmware is in several separate files that are instal...

Страница 45: ...nfigured SNMP alerts to the configured host names or IP addresses Note If you plan to configure Simple Network Management Protocol SNMP traps on the management module you must install and compile the...

Страница 46: ...traps fields to forward alerts to SNMP communities on your network To enable the SNMP agent the following criteria must be met v System contacts must be specified on the General Settings page v The s...

Страница 47: ...ranslate host names into IP addresses 12 If you enabled DNS in the DNS server IP address fields you can specify the IP addresses of up to three DNS servers on your network Each IP address should conta...

Страница 48: ...ement module can be associated with one or more groups and a user would only pass group authentication if he belongs to at least one group associated with the management module Setting up a client to...

Страница 49: ...e belongs only to this group If a prefix filter is used for example RSA this management module belongs to any group whose first three letters are RSA If a wildcard filter is used then this management...

Страница 50: ...eps to configure the LDAP client authentication 1 In the navigation pane click MM Control Network Protocols 2 Scroll down to the Lightweight Directory Access Protocol LDAP Client section and click Set...

Страница 51: ...ermission Attribute When a user is successfully authenticated using an LDAP server the login permissions for this user must be retrieved To retrieve these permissions the search filter sent to the ser...

Страница 52: ...o restrictions when configuring the management module blade servers I O Modules and VPD This user can also perform firmware upgrades on the management module or blade servers restore the management mo...

Страница 53: ...l tasks list to configure the security for the management module 1 Configure the Secure Web server a Disable the SSL server Use the SSL Server Configuration for Web Server section on the MM Control Se...

Страница 54: ...rity is to verify the identity of the management module A certificate contains digital signatures for the certificate authority and the management module If a well known certificate authority issues t...

Страница 55: ...e sure that the SSL server is disabled If it is not disabled select Disabled in the SSL Server field and then click Save 3 In the SSL Server Certificate Management section select Generate a New Key an...

Страница 56: ...re that the SSL server is disabled If it is not disabled select Disabled in the SSL Server field and then click Save 3 In the SSL Server Certificate Management section select Generate a New Key and a...

Страница 57: ...as it is known by the Web browser The browser compares the host name in the resolved Web address to the name that appears in the certificate To prevent certificate warnings from the browser the value...

Страница 58: ...o assign a password to the certificate signing request This field can contain a maximum of 30 characters Unstructured Name Use this field for additional information such as an unstructured name assign...

Страница 59: ...o to step 8 after the signed certificate is returned from the certificate authority 8 In the navigation pane click MM Control Security Scroll to the SSL Server Certificate Management section which loo...

Страница 60: ...on key and certificate for the SSL client is the same as the procedure for the SSL server except that you use the SSL Client Certificate Management section of the Security Web page instead of the SSL...

Страница 61: ...click Import Certificate A progress indicator is displayed as the file is transferred to storage on the management module Remain on this page until the transfer is completed 8 The SSL Client Trusted C...

Страница 62: ...ature provides secure access to the command line interface and the serial over LAN text console redirect features of the management module Secure shell users are authenticated by exchanging user ID an...

Страница 63: ...Hmac sha1 Complete the following steps to create a new secure shell server key 1 In the navigation pane click MM Control Security 2 Scroll to the Secure Shell SSH Server section and make sure that th...

Страница 64: ...he management module configuration v Restore the management module configuration Note If you cannot communicate with a replacement management module through the Web interface or the IBM Director progr...

Страница 65: ...ving to enter common shared information Complete the following steps to restore or modify your current configuration 1 Log in to the management module where you want to restore the configuration For m...

Страница 66: ...te was successful Note The security settings on the Security page are not restored with the restore operation To modify security settings see Secure Web server and secure LDAP on page 42 7 After recei...

Страница 67: ...ssistance by following the troubleshooting procedures that IBM provides in the online help or in the publications that are provided with your system and software The information that comes with your s...

Страница 68: ...about which products are supported by Support Line in your country or region go to http www ibm com services sl products For more information about Support Line and other IBM services go to http www i...

Страница 69: ...TY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Страница 70: ...ountries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United St...

Страница 71: ...applicable regulations IBM offers product return programs in several countries Information on product recycling offerings can be found on IBM s Internet site at http www ibm com ibm environment produ...

Страница 72: ...nformity with the protection requirements of EU Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsib...

Страница 73: ...Chinese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 63...

Страница 74: ...64 BladeCenter Management Module User s Guide...

Страница 75: ...3 error log See event log Ethernet configuring remote connection 8 port cabling 7 Ethernet activity LED 2 Ethernet connector remote management and console 4 Ethernet link status LED 2 event log 16 eve...

Страница 76: ...ing security 43 enabling SSL for LDAP client 52 enabling SSL for secure Web server 50 overview 42 SSL certificate overview 44 SSL client certificate management 50 SSL client trusted certificate manage...

Страница 77: ......

Страница 78: ...Part Number 13N0318 Printed in USA 1P P N 13N0318...

Отзывы: