Table
1.
Abbreviated
list
of
firmware
error
codes
(continued)
Error
code
Failing
device
or
problem
found
Suggested
action
25C0
xx
yy
DIMM
failure:
where
xx
and
yy
are:
xx
Description
01
DIMM4
missing
02
DIMM3
unsupported
and
DIMM4
missing
04
DIMM3
failed
and
DIMM4
missing
10
DIMM3
missing
12
DIMM3
unsupported
14
DIMM3
failed
20
DIMM3
missing
and
DIMM4
unsupported
21
DIMM4
unsupported
22
DIMM3
and
DIMM4
unsupported
24
DIMM3
failed
and
DIMM4
unsupported
40
DIMM3
missing
and
DIMM4
failed
41
DIMM4
failed
42
DIMM4
failed
and
DIMM3
unsupported
44
DIMM3
and
DIMM4
failed
88
DIMM3
and
DIMM4
mismatch
Note:
For
additional
information
about
DIMMs,
see
“Installing
memory
modules”
on
page
24.
1.
Make
sure
that
all
the
DIMMs
in
the
blade
server
are
supported.
Replace
all
the
unsupported
DIMMs.
2.
Make
sure
that
the
DIMMs
are
installed
in
matched
pairs.
If
the
DIMMs
are
not
installed
in
matched
pairs,
reinstall
them
in
matched
pairs.
3.
Make
sure
that
the
DIMMs
are
correctly
seated.
If
necessary,
reseat
the
DIMMs.
4.
Restart
the
blade
server.
5.
Remove
and
reinstall
the
DIMMs
one
at
a
time
until
the
failing
DIMM
is
isolated.
Replace
the
defective
DIMM.
If
the
problem
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
74
BladeCenter
JS20
Type
8842:
Installation
and
User’s
Guide
Содержание BladeCenter JS20
Страница 3: ...BladeCenter JS20 Type 8842 Installation and User s Guide ...
Страница 46: ...34 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Страница 120: ...108 BladeCenter JS20 Type 8842 Installation and User s Guide ...
Страница 131: ......
Страница 132: ... Part Number 31R1749 Printed in USA 1P P N 31R1749 ...