v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
201-xxx-0nn
Failed
memory
test.
Note:
nn
=
DIMM
slot
number,
01
to
04
1.
Reseat
the
DIMM
nn
in
the
indicated
slot.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMM
nn
in
indicated
slot
b.
(Trained
service
technician
only)
System
board
assembly
201-xxx-0nn
Failed
memory
test.
Note:
nn
=
DIMM
slot
number,
05
to
08
1.
Reseat
the
DIMM
nn
in
the
indicated
slot.
2.
Reseat
the
Memory
and
I/O
Expansion
Blade.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMM
nn
in
indicated
slot
b.
Memory
and
I/O
Expansion
Blade
201-xxx-n99
Multiple
DIMM
failure,
see
error
text.
Note:
n
=
number
of
failing
pair;
see
1.
See
the
error
text
for
failing
DIMMs.
2.
If
a
Memory
and
I/O
Expansion
Blade
is
installed,
reseat
it.
3.
If
the
failing
pair
is
n=
1
or
2,
replace
the
system
board.
4.
If
the
failing
pair
is
n=
3
or
4,
replace
the
Memory
and
I/O
Expansion
Blade
202-xxx-00n
Failed
system
cache
test.
Note:
n
=
microprocessor
1
or
microprocessor
2.
1.
Reseat
microprocessor
n
.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
n
b.
(Trained
service
technician
only)
System
board
assembly
217-198-xxx
Could
not
establish
drive
parameters.
1.
Reseat
hard
disk
drive
x
.
2.
Update
the
BIOS
code.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Hard
disk
drive
x
b.
(Trained
service
technician
only)
System
board
assembly
217-xxx-000
Failed
hard
disk
drive
test.
Note:
If
RAID
is
configured,
the
SAS
Attached
Disk
number
refers
to
the
RAID
logical
drive.
1.
Reseat
hard
disk
drive
1.
2.
Replace
hard
disk
drive
1.
Chapter
2.
Diagnostics
63
Содержание BladeCenter HS21 1885
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...