8.
To
install
the
DIMMs,
repeat
the
following
steps
for
each
DIMM
that
you
install:
a.
Turn
the
DIMM
so
that
the
DIMM
keys
align
correctly
with
the
connector
on
the
system
board.
Attention:
To
avoid
breaking
the
retaining
clips
or
damaging
the
DIMM
connectors,
handle
the
clips
gently.
b.
Insert
the
DIMM
by
pressing
the
DIMM
along
the
guides
into
the
connector.
Make
sure
that
the
retaining
clips
snap
into
the
closed
positions.
Important:
If
there
is
a
gap
between
the
DIMM
and
the
retaining
clips,
the
DIMM
has
not
been
correctly
installed.
In
this
case,
open
the
retaining
clips
and
remove
the
DIMM;
then,
reinsert
the
DIMM.
9.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to
Removing
the
blade
server
bezel
assembly
To
install
certain
options,
you
must
first
remove
the
blade
server
bezel
assembly.
The
following
illustration
shows
how
to
remove
the
bezel
assembly.
Control panel
connector
Bezel-assembly
release
Bezel-assembly
release
Control-panel
cable
To
remove
the
blade
server
bezel
assembly,
complete
the
following
steps:
1.
Read
the
safety
information
beginning
on
page
and
2.
Open
the
blade
server
cover
(see
for
instructions).
3.
Press
the
bezel-assembly
release
and
pull
the
bezel
assembly
away
from
the
blade
server
approximately
1.2
cm
(0.5
inch).
4.
Disconnect
the
control-panel
cable
from
the
control-panel
connector.
5.
Pull
the
bezel
assembly
away
from
the
blade
server.
6.
Store
the
bezel
assembly
in
a
safe
place.
Chapter
3.
Installing
options
27
Содержание BladeCenter HS20
Страница 3: ...BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 24: ...12 BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 32: ...20 BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 60: ...48 BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 74: ...62 BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 86: ...74 BladeCenter HS20 Type 7981 Installation and User s Guide...
Страница 87: ......
Страница 88: ...Part Number 31R1715 Printed in USA 1P P N 31R1715...