Step 1240-3
The failure may be caused by the last memory module installed or the system board.
To isolate the failing FRU, do the following:
1. Power off the system.
2. Exchange the last memory module installed.
3. Power on the system.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
Go to
"
MAP 0410: Repair Checkout
"
in Diagnostics Information for
Multiple Bus Systems.
YES
Go to “Step 1240-4.”
Step 1240-4
One of the FRUs remaining in the system unit is defective.
1. Power off the system.
2. Exchange the following FRUs in the order listed.
System Board
Power Supply
3. Power on the system.
Does the system stop with a memory checkpoint displayed on the operator
panel?
NO
Go to
"
MAP 0410: Repair Checkout
"
in Diagnostics Information for
Multiple Bus Systems.
YES
Reinstall the original FRU.
Repeat this step until the defective FRU is identified or all the FRUs have
been exchanged.
If the symptom did not change and all the FRUs have been exchanged,
go to “MAP 1540: Minimum Configuration” on page 2-17.
Chapter 2. Maintenance Analysis Procedures (MAPs)
2-11
Содержание B50
Страница 1: ...RS 6000 7046 Model B50 IBM Service Guide SA38 0564 00...
Страница 2: ......
Страница 3: ...RS 6000 7046 Model B50 IBM Service Guide SA38 0564 00...
Страница 8: ...vi 7046 Model B50 Service Guide...
Страница 16: ...xiv 7046 Model B50 Service Guide...
Страница 21: ...Front View without Covers Chapter 1 Reference Information 1 3...
Страница 30: ...1 12 7046 Model B50 Service Guide...
Страница 94: ...3 30 7046 Model B50 Service Guide...
Страница 100: ...4 6 7046 Model B50 Service Guide...
Страница 106: ...After the System Management Services starts the following screen displays 6 2 7046 Model B50 Service Guide...
Страница 177: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Страница 190: ...A 6 7046 Model B50 Service Guide...
Страница 194: ...X 4 7046 Model B50 Service Guide...
Страница 197: ......