AS/400
Prompt
AS/400
Parameter
3174
Configuration
Questions
Notes
Local adapter
address
ADPTADR
107
Token-Ring Network Address of the Gateway
If the AS/400 system uses a Token-Ring network line to
connect to the 3174 controller, values specified for question
107 and for the ADPTADR parameter on the CRTLINTRN
command must match.
If the AS/400 system uses an Ethernet line through an 8209
LAN Bridge, see
″
Appendix C: Local Area Network
Addressing Considerations
″
in the Communications
Configuration book, for information about specifying the
ADPTADR parameter on the CRTLINETH command.
Connection
number
CNNNBR
423
Host DTE Address (HNAD)
For X.25 lines, the numbers specified on the CRTLINX25
command and in question 423 must match.
368
X.21 Switched Short-Hold Mode Dial Number
For X.21 short-hold mode connections, the numbers
specified on the CRTCTLRWS command and in question
368 must match.
424
3174 DTE Address
For X.25 SVCs, the connection number specified on the
CRTCTLRWS command and in question 424 must match.
Destination
service access
point
DSAP
940
Ring Address Assignment
The value specified for the DSAP parameter on the
CRTCTLRWS command must match the SAP@ specified for
the 3174 on the Ring Address Assignment display. Used for
token-ring only.
Exchange
identifier
EXCHID
215
Physical Unit Identification
For switched connections, the 5-digit hexadecimal value
specified for question 215 must match the last 5 digits of the
exchange identifier specified on the CRTCTLRWS
command.
Link type
LINKTYPE
101
Host Attachment
(3174)
Values specified on the CRTCTLRWS command and for
question 101 must match as follows:
v
LINKTYPE(*SDLC), 101 = 2
v
LINKTYPE(*X25), 101 = 3
v
LINKTYPE(*LAN), 101 = 7 (token ring)
v
LINKTYPE(*LAN), 101 = 8 (Ethernet)
Modem data
rate select
MODEMRATE
318
Full- or Half-Speed Transmission
The values specified for the MODEMRATE parameter on the
CRTLINSDLC and CRTLINX25 commands must match
question 318 as follows:
v
If MODEMRATE(*FULL), 318 = 0
v
If MODEMRATE(*HALF), 318 = 1
Chapter 7. Communicating with remote workstation controllers
59
Содержание AS/400
Страница 1: ...iSeries Networking iSeries Communications Management ERserver...
Страница 2: ......
Страница 3: ...iSeries Networking iSeries Communications Management ERserver...
Страница 8: ...2 Version 5...
Страница 10: ...4 Version 5...
Страница 12: ...6 Version 5...
Страница 22: ...For more information about creating subsystems see the Work Management book 16 Version 5...
Страница 26: ...20 Version 5...
Страница 34: ...Example 3 AS 400 system for DLUR support with the host system 28 Version 5...
Страница 36: ...30 Version 5...
Страница 46: ...40 Version 5...
Страница 57: ...Chapter 7 Communicating with remote workstation controllers 51...
Страница 63: ...Chapter 7 Communicating with remote workstation controllers 57...
Страница 82: ...Example 2 AS 400 to 4690 PEER connection over token ring network 76 Version 5...
Страница 83: ...Chapter 7 Communicating with remote workstation controllers 77...
Страница 84: ...78 Version 5...
Страница 102: ...96 Version 5...
Страница 103: ......
Страница 104: ...Printed in U S A...