Yes:
Go to step 8.
8.
Select the parent or child of the resource for the replaced part from the
Resource Repair Action
menu if necessary. When a test is run on a resource in system verification mode, and that resource
has an entry in the error log, if the test on the resource was successful, the
Resource Repair Action
menu appears. Complete the following steps to update the error log to indicate that a
system-detectable part has been replaced.
Note:
This changes the indicator light for the part from the fault state to the normal state.
a.
From the
Resource Repair Action
menu, select the parent or child of the resource that has been
replaced. If the repair action was to reseat a cable or adapter, select the resource associated with
that repair action. If the resource associated with your action does not appear on the Resource
List, select
sysplanar0
. Press Enter.
b.
Select
Commit
after you make your selections.
c.
If the
No Trouble Found
display appears, go to step 9.
9.
If you changed the service processor or network settings, as instructed in previous procedures,
restore the settings to the values they had prior to servicing the system.
10.
Did you do any hot-plug procedures before doing this procedure?
No:
Go to step 11.
Yes:
Go to step 12.
11.
Start the operating system, with the system or logical partition in normal mode. Were you able to
start the operating system?
No:
Contact your service provider.
This ends the procedure.
Yes:
Go to step 12.
12.
Are the indicator lights still on?
v
No. This ends the procedure.
v
Yes.
Turn off the lights. See one of the following for instructions: Changing service indicators
Verifying a repair
Use these procedures to verify hardware operation after making repairs to the system.
Choose from the following options:
v
To verify the repair of a system that is currently powered off, go to step 1.
v
To verify the repair of a system that is currently powered on with no operating system loaded, go to
step 3 on page 68.
v
To verify the repair of a system that is currently powered on and that has an operating system loaded,
go to step 5 on page 68.
1.
Power on the server and all attached I/O enclosures.
Did all the enclosures power on?
Yes:
Go to step 3 on page 68.
↓
Go to step 3 on page 68.
No:
Continue with the next step.
2.
Choose from the following options:
Power supplies
67
Содержание 9117-MMB
Страница 1: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 2: ......
Страница 3: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 112: ...100 Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 113: ......
Страница 114: ... Printed in USA ...