correctly. If you cannot correct the problem, collect all SRNs or any other reference code
information that you see. If the system does not start or you have no login prompt, see: Problems
with loading and starting the operating system.
If the system is partitioned, note the logical partition in which you replaced the part. Contact your
service provider for assistance.
v
Yes:
Go to step 4
4.
At the command prompt, type
diag —a
and press Enter to check for missing resources. If you see a
command prompt, go to step 5.
If the
Diagnostic selection
menu is shown with
M
appearing next to any resource, follow these
steps:
a.
Select the resource and press Enter.
b.
Select
Commit
.
c.
Follow any instructions that are shown.
d.
If a
Do you want to review the previously displayed error?
message is shown, select
Yes
and press
Enter.
e.
If an SRN is shown, suspect a loose card or connection. If no obvious problem is shown, record
the SRN and contact your service provider for assistance..
f.
If no SRN is shown, go to 5.
5.
Test the part by doing the following:
a.
At the command line, type
diagmenu
and press Enter.
b.
From the
Function Selection
menu, select
Advanced Diagnostics Routines
and press Enter.
c.
From the
Diagnostic Mode Selection
menu, select
System Verification
and press Enter.
d.
Select
All Resources
, or select the diagnostics for the individual part to test only the part you
replaced, and any devices that are attached to the part you replaced and press Enter.
Did the
Resource Repair Action
menu appear?
No:
Go to step 6.
Yes:
Go to step 7.
6.
Did the
Testing Complete, No trouble was found
message appear?
v
No:
There is still a problem. Contact your service provider.
This ends the procedure.
v
Yes:
Select
Log Repair Action
, if not previously logged, from the
Task Selection
menu to update
the error log. If the repair action was reseating a cable or adapter, select the resource associated
with that repair action. If the resource associated with your action is not displayed on the
Resource List, select
sysplanar0
and press Enter.
Tip:
This action changes the indicator light for the part from the fault state to the normal state.
Go to step 9 on page 67
7.
Select the resource for the replaced part from the
Resource Repair Action
menu. When a test is run
on a resource in system verification mode, and that resource has an entry in the error log, if the test
on the resource was successful, the
Resource Repair Action
menu appears. Complete the following
steps to update the error log to indicate that a system-detectable part has been replaced.
Note:
On systems with a indicator light for the failing part, this changes the indicator light to the
normal state.
a.
Select the resource that has been replaced from the
Resource Repair Action
menu. If the repair
action was reseating a cable or adapter, select the resource associated with that repair action. If
the resource associated with your action does not appear on the Resource List, select
sysplanar0
.
Press Enter.
b.
Select
Commit
after you make your selections. Did another
Resource Repair Action
display
appear?
No:
If the
No Trouble Found
display appears, go to step 9 on page 67
66
Power Systems: Power supplies for the 9117-MMB, 9117-MMC, 9179-MHB, or 9179-MHC
Содержание 9117-MMB
Страница 1: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 2: ......
Страница 3: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 112: ...100 Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Страница 113: ......
Страница 114: ... Printed in USA ...