b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
3;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
6.
Next,
route
the
cable
through
the
node
6
cable-management
arm.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
5;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
6.
Next,
route
the
cable
through
the
node
6
cable-management
arm.
9.
Connect
the
SMP
Expansion
cables
to
node
7:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
6;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
7.
Next,
route
the
cable
through
the
node
7
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
2;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
7.
Next,
route
the
cable
through
the
node
7
cable-management
arm.
c.
Connect
one
end
of
an
SMP
Expansion
cable
to
port
3
on
node
7;
then,
route
the
cable
through
the
node
7
cable-management
arm.
Use
a
2.3-m
(7.6-foot)
SMP
Expansion
cable
for
this
connection.
10.
Connect
the
SMP
Expansion
cables
to
node
8:
a.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
1
on
node
5;
then,
connect
the
opposite
end
of
the
cable
to
port
1
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
b.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
2
on
node
4;
then,
connect
the
opposite
end
of
the
cable
to
port
2
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
c.
Locate
the
SMP
Expansion
cable
that
is
connected
to
port
3
on
node
7;
then,
connect
the
opposite
end
of
the
cable
to
port
3
of
node
8.
Next,
route
the
cable
through
the
node
8
cable-management
arm.
11.
Route
any
remaining
cables
through
the
cable-management
arms.
12.
Secure
the
cables
in
the
cable-management
arms
with
the
hook-and-loop
straps
that
come
with
the
server.
13.
Configure
the
scalable
partition.
See
“Using
the
Scalable
Partition
Web
Interface”
on
page
51.
Chapter
2.
Installing
options
29
Содержание 88728AU - System x3950 - 8872 Datacenter High Availability
Страница 3: ...IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Страница 42: ...30 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Страница 68: ...56 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Страница 104: ...92 IBM System x3950 Type 8872 and System x3950 E Type 8874 Installation Guide...
Страница 105: ......
Страница 106: ...Part Number 31R1855 Printed in USA 1P P N 31R1855...