Table 2. Troubleshooting charts (continued)

Device

Suggested action

Ethernet switch-module
firmware graphics shows a
blank panel when the blade
server is present but powered
off.

If the Wake-on-LAN (WOL) feature is disabled on a blade server, and the blade
server is turned off, the switch module internal port link to that blade is down. This is
not an error, but the graphic of the BladeCenter unit might show a blank panel
instead of a blade server in that bay.

Note:

You can enable or disable the WOL feature on a blade server through the

management-module Web interface or through the IBM Director console. Do not rely
on the BladeCenter graphic in the Ethernet switch-module firmware Web interface to
determine the presence or absence of blade servers in the BladeCenter unit.

Ethernet switch-module log
reports elapsed time, not time
of day.

The timestamp on entries in the Ethernet switch module log uses elapsed time (since
last switch restart). The timestamp on entries restarts from 0 each time the switch is
restarted, although the entries do remain in order of occurrence.

Ethernet disconnect notice
will not appear when running
Windows 2000.

If an Ethernet cable is accidentally removed from the back of the BladeCenter unit,
the small red X (disconnect notice) that normally would appear to indicate that the
cable was disconnected will not appear in the bottom right of the screen. The
disconnect notice does not appear because the blade server Ethernet controller
connects to the Ethernet switch module through integrated circuitry inside the
BladeCenter unit.

When troubleshooting Ethernet-related problems, ensure that the Ethernet cables on
the back of the BladeCenter unit are connected properly.

The default IP address set by
the Ethernet switch module
does not match the one
assigned by the management
module.

When troubleshooting Ethernet-related problems, ensure that the Ethernet cables on
the back of the BladeCenter unit are connected properly.

Updating the Ethernet switch
module configuration through
the management module
does not save the switch
NVRAM.

When you use the management-module Web interface to update the Ethernet switch
module configuration, the management module firmware writes its settings for the
switch module only to the management module NVRAM; it does not write its settings
for the switch module to the switch-module NVRAM.

If the switch module restarts when the management module is not able to apply the
IP address it has in NVRAM for the switch module, the switch module will use
whatever IP address it has in its own NVRAM. If the two IP addresses are not the
same, you might not be able to manage the Ethernet switch module any more.

The management module cannot apply the switch IP address from its NVRAM if:

v

The management module is restarting

v

The management module has failed

v

The management module has been removed from the unit.

When you use the management-module Web interface to update the Ethernet switch
module configuration, the management module firmware writes its settings for the
switch module only to the management module NVRAM; it does not write its settings
for the switch module to the switch module NVRAM.

If the switch module restarts when the management module is not able to apply the
IP address it has in NVRAM for the switch module, the switch module will use
whatever IP address it has in its own NVRAM. If the two IP addresses are not the
same, you might not be able to manage the Ethernet switch module any more.

The management module cannot apply the switch IP address from its NVRAM if:

v

The management module is restarting

v

The management module has failed

v

The management module has been removed from the unit.

Keyboard problems

64

BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide

Содержание 8677 - BladeCenter Rack-mountable - Power...

Страница 1: ...BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 2: ......

Страница 3: ...BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 4: ...and IBM Systems Environmental Notices and User Guide documents on the IBM Documentation CD 17th Edition May 2010 Note The most recent version of this document is available at http www ibm com systems...

Страница 5: ...ladeCenter unit 21 BladeCenter unit power requirement 22 BladeCenter power configuration 22 Firmware updates 22 Configuring the BladeCenter unit 23 Configuring the management module 23 Communicating w...

Страница 6: ...ath Diagnostics table 69 Temperature error messages 70 Blower error messages 70 Power error messages 71 Blade server error messages 72 KVM error message 72 I O module error messages 72 Management modu...

Страница 7: ...statement 131 Avis de conformit la r glementation d Industrie Canada 131 Australia and New Zealand Class A statement 131 United Kingdom telecommunications safety requirement 131 European Union EMC Di...

Страница 8: ...vi BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 9: ...ok before performing any of the instructions See Safety information on page 85 Lea todas as instru es de cuidado e perigo antes de executar qualquer opera o Prenez connaissance de toutes les consignes...

Страница 10: ...ownload the most current diagnostic H8 flash and device driver files from http www ibm com systems support on the World Wide Web Support telephone numbers View support telephone numbers at http www ib...

Страница 11: ...ter E models do have a diskette drive in the media tray In this document this difference is noted when necessary to describe differences that exist between current and older model offerings 2 The illu...

Страница 12: ...labels comes with each blade server Write whatever identifying information you want on a label and place it on the BladeCenter bezel just below the blade server as shown in the following illustration...

Страница 13: ...Acrobat Reader or xpdf The Documentation Browser automatically detects the regional settings in use in your system and displays the documents in the language for that region if available If a documen...

Страница 14: ...ppears in the documentation has a number that you can use to locate the corresponding statement in your language in the Safety Information book v BladeCenter Type 8677 Rack Installation Instructions T...

Страница 15: ...ardous to you A caution statement is placed just before the description of a potentially hazardous procedure step or situation v Danger These statements indicate situations that can be potentially let...

Страница 16: ...ne active one redundant Upgradeable microcode v Management module firmware v I O module firmware some I O module types v Blade server firmware Security features v Login password for remote connection...

Страница 17: ...ment modules one active one redundant Upgradeable microcode v Management module firmware v I O module firmware some I O module types v Blade server firmware Security features v Login password for remo...

Страница 18: ...it Note The illustrations in this document might differ slightly from your hardware Attention To maintain proper system cooling each module bay must contain either a module or a filler module each bla...

Страница 19: ...ows the locations of components and indicators on the front of the BladeCenter Type 8677 and 1881 unit See BladeCenter components controls and LEDs on page 13 for details about these components and in...

Страница 20: ...ts and indicators on the rear of the BladeCenter Type 8677 and 1881 unit See BladeCenter components controls and LEDs on page 13 for details about these components and indicators 10 BladeCenter E Type...

Страница 21: ...ld the Shift key 2 Press keyboard keys in the following sequence NumLock blade server number Enter 3 Release the Shift key Starting the BladeCenter unit Important For the LEDs on each system LED panel...

Страница 22: ...e power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power...

Страница 23: ...is lit it indicates that the optical drive is in use Optical drive eject button Press this button to release a CD or DVD from the optical drive Diskette drive activity LED not shown in illustration Fo...

Страница 24: ...e home page http www ibm com servers IBM Server home page http www ibm com eserver xseries IBM server xSeries home page Power on Location Over temperature Information System error System service card...

Страница 25: ...eir speed as required to control internal BladeCenter temperature Blower error LEDs The amber LED on each blower is lit and stays lit when an error has been detected in the blower The system error LED...

Страница 26: ...320 watt power modules only When this amber LED is lit it indicates that an error has been detected in the power module When this LED is lit the BladeCenter unit system error LED is also lit Managemen...

Страница 27: ...creasing the blower speed This LED turns off automatically when there is no longer an over temperature condition Information When this amber LED is lit a noncritical event has occurred that requires a...

Страница 28: ...ht flashes rapidly the blade server has not yet synchronized with the management module and the power button will have no effect See the IBM BladeCenter Type 8677 Installation and User s Guide for mor...

Страница 29: ...ervers on the World Wide Web v To register go to http www ibm com support mysupport v To profile go to http www ibm com systems support Important 1 Do not switch control of a shared removable media dr...

Страница 30: ...20 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 31: ...ide or Command Line Interface Reference Guide for your management module type for instructions v The internal Ethernet management port on each I O module for communication with the management module Y...

Страница 32: ...he power modules in power bays 1 and 2 provide power to blade bays 1 through 6 and to common components in the BladeCenter unit The power modules in power bays 3 and 4 provide power to blade bays 7 th...

Страница 33: ...r accounts DHCP or Wake on LAN See the BladeCenter Management Module User s Guide and the BladeCenter Management Module Command Line Interface Reference Guide for instructions Communicating with the I...

Страница 34: ...dule bay 1 you must configure the network switch that the pass thru module is connected to see the documentation that comes with the network switch 2 You can set up Ethernet failover by installing an...

Страница 35: ...configuration ports v Set up the initial security profile for the BladeCenter unit including user names passwords enablement or disablement of management services and so forth v Optionally configure...

Страница 36: ...ector about director52 extensions rdm html on the World Wide Web for updated information about the RDM program and to download the software BladeCenter networking guidelines Your networking administra...

Страница 37: ...hes within the BladeCenter chassis an external network device is required for data packets to flow from one internal switch to the other The management module has a separate internal 100 Mbps link to...

Страница 38: ...e following guidelines when creating this topology 1 The external ports on the BladeCenter switch modules are designed for point to point full duplex operation to a compatible LAN switch or router Con...

Страница 39: ...t It is run from the IBM Director Management Console window under the BladeCenter task in the Task panel To obtain the Real Time Diagnostics program go to the following Web site http www ibm com syste...

Страница 40: ...ee BladeCenter unit power controls and indicators on page 11 for the location of error LEDs see the documentation that comes with your blade server for the location of error LEDs on the blade If the c...

Страница 41: ...nstalled remove them first Blade servers are installed from the front of the BladeCenter unit without sliding the BladeCenter unit into or out of the rack Detailed instructions for installing a BladeC...

Страница 42: ...l v Cables for the option modules are routed according to the illustrations and instructions in this document v A failed blower is replaced as soon as possible to restore cooling redundancy Handling s...

Страница 43: ...e installed When replacing a module do not operate the BladeCenter unit for more than one minute without either a module or a filler module installed in each module bay Management module Your BladeCen...

Страница 44: ...No more than two fibre channel switch modules can be connected to the BladeCenter unit If you install an I O expansion option on any blade server you must install a hot swap I O module of the same ne...

Страница 45: ...de server uses through your operating system settings 2 The routing of an Ethernet controller to a particular I O module bay depends on the type of blade server You can verify which Ethernet controlle...

Страница 46: ...to blade bays 1 through 6 3 and 4 Provides power to blade bays 7 through 14 Power modules are not needed in bays 3 and 4 until you begin installing blade servers and options in blade bays 7 through 1...

Страница 47: ...a problem with one of these parts contact a service technician Complete the following steps to install a module Note These instructions assume the BladeCenter unit is connected to power 1 Read the sa...

Страница 48: ...module is lit 9 If you have other modules to install do so now otherwise go to step 10 10 Replace the acoustic module option if you removed it in step 2 Removing a module Complete the following steps...

Страница 49: ...emoving a management module you might prefer to stop all management module local and remote sessions before proceeding to avoid unexpected termination of sessions 3 Disconnect any cables from the modu...

Страница 50: ...el is replicated on the acoustic module for visibility Installing an acoustic module increases the length of a BladeCenter unit and requires use of an enterprise rack Installing the acoustic module op...

Страница 51: ...s removable media drives keyboard mouse and video ports USB port remote monitoring port from the BladeCenter unit reducing the server physical size and reducing the number of cables needed Blade serve...

Страница 52: ...ed mirroring Important 1 To ensure proper cooling and system reliability make sure that each of the SCSI hard disk drive bays on the SCSI storage expansion unit contains either a hot swap SCSI hard di...

Страница 53: ...option require two adjacent blade bays b If you install a blade server or option in bay 7 through 14 you must install power modules in power bays 3 and 4 4 Remove the filler blade from the bay and st...

Страница 54: ...de server into a different bay than the one from which it was removed could have unintended consequences Some configuration information and update options are established according to bay number You m...

Страница 55: ...Important safety information on page vii Installation guidelines on page 31 and Handling electrostatic discharge sensitive devices on page 88 2 Shut down the blade server operating system then press t...

Страница 56: ...it and the location of the LEDs on the modules See the Installation and User s Guide for your blade server for the location of the LEDs on the blade servers Input output connectors Your BladeCenter ha...

Страница 57: ...aining blower continues to cool the BladeCenter and blades Important 1 The failed blower module must be replaced within two minutes during service 2 If ambient temperature is 72 F or below the BladeCe...

Страница 58: ...ut of the BladeCenter Reverse these instructions to reinstall the media tray Removing the media tray cover Complete the following steps to remove the media tray cover Note v Read Installation guidelin...

Страница 59: ...s on the left on the diskette drive the wire spring is on the right Complete the following steps to replace the optical drive or the diskette drive Note v Read Installation guidelines on page 31 v Rea...

Страница 60: ...te drive reconnect the cable at the rear of the drive Installing SuSE to a SCSI drive The SuSE Linux operating system sees the diskette drive as a SCSI device When you are trying to install SuSE to a...

Страница 61: ...D interposer board Note The CD interposer board is only present in BladeCenter unit models that have a media tray with a diskette drive Complete the following steps to replace the CD interposer board...

Страница 62: ...ing electrostatic discharge sensitive devices on page 88 1 Shut down the operating systems and turn off any blades in the BladeCenter 2 Turn off the BladeCenter and any attached devices see Shutting d...

Страница 63: ...chassis reverse the previous steps Media cable tray Note The media cable is only present in BladeCenter unit models that have a media tray with a diskette drive The media cable tray is between the med...

Страница 64: ...Media cable tray 3 Remove the media tray cable To replace or reinstall the media cable tray reverse the previous steps 54 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshoot...

Страница 65: ...s that hold the midplane to the SPC chassis 4 Pull the midplane away from the SPC chassis Alignment pins Midplane Screws 12 places 5 Install the replacement midplane by reversing the previous steps Sy...

Страница 66: ...he midplane 4 Unscrew the two fasteners on the LED panel 5 Remove the LED panel from the SPC chassis LED panel Cable Note You might need to push the LED panel cable toward the panel to leverage the pa...

Страница 67: ...les with more than two columns multiple columns are required to describe the error symptoms Take the action or replace the FRU suggested first in the list of the right hand column then try the server...

Страница 68: ...er in this way is considered an improper shutdown by the Wake on LAN feature and the Wake on LAN feature will not restart the blade server 2 Unlatch and slide the blade server partially out of the Bla...

Страница 69: ...safely stop the media tray devices on the blade server that currently owns the media tray similar to the following 1 Double click the Unplug or Eject Hardware icon in the Windows taskbar at the bottom...

Страница 70: ...page at http www ibm com systems support The necessary workaround is described in the instructions for your operating system X does not start in Red Hat 7 3 when the blade server does not own the KVM...

Страница 71: ...4x768 60Hz 1 Run the graphical interface to the AutoYaST control file to set the VESA video mode to 1040x768 60Hz The graphical interface creates the AutoYaST control file 2 Edit the resulting AutoYaS...

Страница 72: ...d to the diskette drive 2 Create a directory for the diskette drive under mnt by running mkdir mnt floppy 3 Mount the diskette drive by typing mount mnt floppy Note When running Linux you must unmount...

Страница 73: ...in a blade server is operating system dependent In the blade server Configuration Setup Utility program the Ethernet port designated as Planar Ethernet 1 is routed to Ethernet switch module 2 and the...

Страница 74: ...e management module When troubleshooting Ethernet related problems ensure that the Ethernet cables on the back of the BladeCenter unit are connected properly Updating the Ethernet switch module config...

Страница 75: ...ole can have keyboard entry problems Use the Microsoft Java Virtual Machine JVM or Java Runtime Environment JRE on the blade server instead of using the Sun Java Virtual Machine The Microsoft JVM come...

Страница 76: ...appears See Undetermined problems on page 75 The screen is wavy unreadable rolling distorted or has screen jitter If the monitor self tests show the monitor is working properly consider the location o...

Страница 77: ...wer module are on and the power module error LED 2320 watt power modules only on the power module is off 4 If you just installed an option remove it and restart the BladeCenter unit If the BladeCenter...

Страница 78: ...nd update the I O module configuration saving the new configuration saves only to the I O module NVRAM not to the management module NVRAM The management module will not be able to communicate with the...

Страница 79: ...A noncritical event has occurred that should be looked at such as the wrong I O module inserted in a bay or power needs that exceed the capacity of power modules currently installed Check the error l...

Страница 80: ...fault 1 Ensure that the system is being properly cooled see System reliability considerations on page 32 2 Replace power supply x Power supply x temperature warning 1 Ensure that the system is being p...

Страница 81: ...module 2 Reseat the power modules 3 Replace the power modules 4 Replace the management module System over recommended voltage for 1 8V 1 Reseat the management module 2 Replace the management module S...

Страница 82: ...upported by the management module KVM error message Note See Chapter 7 Parts listing BladeCenter Type 8677 and 1881 on page 77 to determine which components should be replaced by a field service techn...

Страница 83: ...y Take action as required System log 75 full Information only Take action as required System log full Information only Take action as required Management module network initialization complete Informa...

Страница 84: ...Type 8677 and 1881 on page 77 to determine which components should be replaced by a field service technician Message Action Failure reading I2C device Check devices on bus 1 1 Reset the management mo...

Страница 85: ...rrect the problem remove or disconnect the BladeCenter components one at a time to a minimal configuration or until you locate the problem You do not need to remove power from the system Complete the...

Страница 86: ...has been working what changes were made prior to it failing Is this the original reported failure v Diagnostics version type and version level v Hardware configuration Print print screen configuration...

Страница 87: ...tp www ibm com servers IBM Server home page http www ibm com eserver xseries IBM server xSeries home page Power on Location Over temperature Information System error 1 2 3 4 5 6 7 8 9 Note Field repla...

Страница 88: ...3Rx 3Sx 3Tx 3Xx 4Sx 4Tx 26K5423 CRU 6 Combo drive 24 24 24 8X alternate models 3Rx 3Xx 26K5439 CRU 6 DVD ROM 8X primary model 3Rx 39M3531 CRU 6 DVD ROM 8X alternate model 3Xx 26K5393 CRU 6 UltraSlim...

Страница 89: ...Power supply module 2320 watt model 4Sx 4Tx 39Y7400 CRU 4 Power supply filler models 1Xx 2Xx 49P2519 CRU 4 Power supply filler models 1Xx 22x 3Rx 3Xx 39M3262 CRU 4 Power Supply Filler models 3Sx 3Tx...

Страница 90: ...iniband optional all models 44V5082 CRU Cable Nortel optional all models 26K6541 CRU Cable Nortel CX4 1 5 meter optional all models 32R1940 CRU Cable Nortel CX4 3 meter optional all models 32R1944 CRU...

Страница 91: ...26R0888 CRU Module CPM optional all models 46C7101 CRU Module CPM optional all models 39Y9169 CRU Module fibre channel model CXx optional all models 59P6621 FRU Module optical optional all models 02R9...

Страница 92: ...h Infiniband optional all models 26K6452 CRU Switch Infiniband card module optional all models 32R1903 CRU Switch McDATA fibre channel optional all models 32R1792 CRU Switch Nortel Ethernet 6 Pt Fiber...

Страница 93: ...agnostic tests that you can perform Most systems operating systems and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes If y...

Страница 94: ...Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through your IBM reseller or IBM Services To locate a reseller authorized by IBM to provide war...

Страница 95: ...causes hazards to the customer or that makes the equipment unsafe v Before you start the machine ensure that other service representatives and the customer s personnel are not in a hazardous position...

Страница 96: ...lling main units v Before you start to work on the machine unplug the power cord If you cannot unplug it ask the customer to power off the wall box that supplies power to the machine and to lock the w...

Страница 97: ...assist you in identifying potentially unsafe conditions on these products Each machine as it was designed and built had required safety items installed to protect users and service personnel from inj...

Страница 98: ...charge Notes 1 Use product specific ESD procedures when they exceed the requirements noted here 2 Make sure that the ESD protective devices you use have been certified ISO 9000 as fully effective When...

Страница 99: ...Traditional Chinese v French v German v Italian v Japanese v Korean v Spanish Important All caution and danger statements in this IBM documentation begin with a number This number is used to cross re...

Страница 100: ...water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and co...

Страница 101: ...CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser...

Страница 102: ...he power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device e...

Страница 103: ...nt when the blade is connected to the power source Always replace the blade cover before installing the blade Importante Todas as instru es de cuidado e perigo da IBM documentation come am com um n me...

Страница 104: ...ou na estrutura v Desconecte cabos de alimenta o sistemas de telecomunica o redes e modems antes de abrir as tampas dos dispositivos a menos que especificado de maneira diferente nos procedimentos de...

Страница 105: ...ateria pelo correio para a IBM Instru o 3 PRECAUCI N Quando produtos a laser unidades de CD ROM unidades de DVD dispositivos de fibra tica transmissores etc estiverem instalados observe o seguinte v N...

Страница 106: ...a ao dispositivo O dispositivo tamb m pode ter mais de um cabo de alimenta o Para remover toda a corrente el trica do dispositivo assegure que todos os cabos de alimenta o estejam desconectados da fon...

Страница 107: ...a unidade remova todas as l minas para reduzir o peso Instru o 21 CUIDADO A energia uma amea a quando a l mina estiver conectada fonte de alimenta o Sempre substitua a cobertura da l mina antes de ef...

Страница 108: ...98 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 109: ...Laser Klass 1 Appendix B Related service information 99...

Страница 110: ...100 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 111: ...Appendix B Related service information 101...

Страница 112: ...102 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 113: ...Appendix B Related service information 103...

Страница 114: ...Luokan 1 Laserlaite 104 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 115: ...anglais avec ses versions traduites dans la pr sente section Par exemple si une consigne de type Attention est pr c d e du chiffre 1 ses traductions sont galement pr c d es du chiffre 1 dans la pr sen...

Страница 116: ...s de l unit mettez celle ci hors tension et d connectez ses cordons d alimentation ainsi que les c bles qui la relient aux r seaux aux syst mes de t l communication et aux modems sauf instruction cont...

Страница 117: ...laser sont install s tels que des unit s de CD ROM ou de DVD des p riph riques contenant des fibres optiques ou des metteurs r cepteurs prenez connaissance des informations suivantes v N ouvrez pas c...

Страница 118: ...s l arriv e de courant lectrique l int rieur de la machine Il se peut que votre unit dispose de plusieurs cordons d alimentation Pour isoler totalement l unit du r seau lectrique d branchez tous les c...

Страница 119: ...nstaller le Serveur lame Wichtig Alle Sicherheitshinweise in dieser IBM documentation beginnen mit einer Nummer Diese Nummer verweist auf einen englischen Sicherheitshinweis mit den bersetzten Version...

Страница 120: ...ng zu den angeschlossenen Netzkabeln Telekommunikationssystemen Netzwerken und Modems ist vor dem ffnen des Geh uses zu unterbrechen Es sei denn dies ist in den zugeh rigen Installations und Konfigura...

Страница 121: ...Einheiten mit Glasfaserkabeln oder Transmitter installiert ist beachten Sie folgendes v Das Entfernen der Abdeckungen des CD ROM Laufwerks kann zu gef hrlicher Laserstrahlung f hren Es befinden sich...

Страница 122: ...wird die Stromversorgung f r den Server nicht unterbrochen Der Server k nnte auch mehr als ein Netzkabel aufweisen Um die gesamte Stromversorgung des Servers auszuschalten mu sichergestellt werden da...

Страница 123: ...di attenzione e di pericolo riportati nella pubblicazione IBM documentation iniziano con un numero Questo numero viene utilizzato per confrontare avvisi di attenzione o di pericolo in inglese con le...

Страница 124: ...esenti danni all apparecchiatura stessa v Scollegare i cavi di alimentazione i sistemi di telecomunicazioni le reti e i modem prima di aprire i coperchi delle unit se non diversamente indicato nelle p...

Страница 125: ...izioni nazionali e locali Avviso 3 ATTENZIONE Quando si installano prodotti laser come ad esempio le unit DVD CD ROM a fibre ottiche o trasmettitori prestare attenzione a quanto segue v Non rimuovere...

Страница 126: ...sattiva la corrente elettrica fornita all unit L unit potrebbe disporre di pi di un cavo di alimentazione Per disattivare la corrente elettrica dall unit accertarsi che tutti i cavi di alimentazione s...

Страница 127: ...unit rimuovere tutte le lame in modo da ridurre il peso Avviso 21 ATTENZIONE Quando la lama collegata alla sorgente elettrica presente una tensione pericolosa Sostituire sempre il coperchio della lama...

Страница 128: ...118 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 129: ...Appendix B Related service information 119...

Страница 130: ...120 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 131: ...Appendix B Related service information 121...

Страница 132: ...122 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 133: ...gl s con las versiones traducidas que de dichas declaraciones pueden encontrarse en esta secci n Por ejemplo si una declaraci n de peligro empieza con el n mero 1 las traducciones de esta declaraci n...

Страница 134: ...bles de alimentaci n sistemas de telecomunicaciones redes y m dems conectados antes de abrir las cubiertas del dispositivo a menos que se indique lo contrario en los procedimientos de instalaci n y co...

Страница 135: ...o o la legislaci n local Declaraci n 3 PRECAUCI N Cuando instale productos l ser como por ejemplo CD ROM unidades DVD dispositivos de fibra ptica o transmisores tenga en cuenta las advertencias siguie...

Страница 136: ...inistrada al dispositivo Es posible tambi n que el dispositivo tenga m s de un cable de alimentaci n Para eliminar la corriente el ctrica del dispositivo aseg rese de desconectar todos los cables de a...

Страница 137: ...levantar a unidade retire todas as l minas para diminuir o peso Declaraci n 21 PRECAUCI N Existe energia perigosa quando a l mina est ligada fonte de alimenta o Substitua sempre a cobertura da l mina...

Страница 138: ...128 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 139: ...s or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically mad...

Страница 140: ...speed is the variable read rate Actual speeds vary and are often less than the possible maximum When referring to processor storage real and virtual storage or channel volume KB stands for 1024 bytes...

Страница 141: ...e the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept a...

Страница 142: ...roduct In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures European Community contact IBM Technical Regulations Pascals...

Страница 143: ...IBM power cord part number Used in these countries and regions 39M5354 China 39M5330 Australia Fiji Kiribati Nauru New Zealand Papua New Guinea 39M5282 Afghanistan Albania Algeria Andorra Angola Armen...

Страница 144: ...Zambia Zimbabwe 39M5322 Liechtenstein Switzerland 39M5298 Chile Italy Libyan Arab Jamahiriya 39M5310 Israel 39M5262 Antigua and Barbuda Aruba Bahamas Barbados Belize Bermuda Bolivia Brazil Caicos Isla...

Страница 145: ...n 13 specifications 5 Dynamic Host Control Protocol 23 E eject button diskette drive 13 optical drive 13 electrical input 5 6 7 electronic emission Class A notice 131 environment 5 6 7 Ethernet contro...

Страница 146: ...3 power module 36 error LED description 16 specifications 5 power supply specifications 6 7 power on LED system LED panel 17 problem hardware 29 management module 65 power 67 problem solving 29 proble...

Страница 147: ...web site publication ordering 83 support 83 support line telephone numbers 84 Web site 1 compatible options 32 weight 5 6 7 World Wide Web 1 Index 137...

Страница 148: ...138 BladeCenter E Type 8677 and 1881 Hardware Maintenance Manual and Troubleshooting Guide...

Страница 149: ......

Страница 150: ...Part Number 49Y0145 Printed in USA 1P P N 49Y0145...

Отзывы: