Hot-swap fan
Fan air
baffle
Note:
Replace a hot-swap fan within 30 seconds of removal.
Attention:
Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which could
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when working
inside the server with the power on.
9. Remove the power-supply filler from the second power-supply bay.
10. Slide the new power supply partially into the empty power-supply bay. Pinch
the orange release latch and push the power supply the rest of the way into
the bay until it is seated.
11. Install the left-side cover (see “Completing the installation” on page 105).
12. Connect one end of the new power cord into the connector on the back of
power supply, and connect the other end of the power cord to a properly
grounded electrical outlet.
Chapter 2. Installing optional devices
103
Содержание 7380E1U
Страница 1: ...IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 2: ......
Страница 3: ...IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 8: ...vi IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 64: ...48 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 66: ...50 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 68: ...52 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 79: ...Chapter 2 Installing optional devices 63 ...
Страница 142: ...126 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 152: ...136 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 158: ...142 IBM System x3500 M3 Type 7380 Installation and User s Guide ...
Страница 159: ......
Страница 160: ... Part Number 81Y6295 Printed in USA 1P P N 81Y6295 ...