Step
20
This
step
runs
the
AIX
diagnostics
to
determine
the
problem
or
to
verify
a
fix.
1.
Press
the
power
switch
to
turn
on
the
power.
2.
Press
the
load/unload
button
to
eject
any
media
currently
loaded
in
the
devices.
3.
Obtain
the
appropriate
test
media
for
the
device.
Inspect
the
test
media
for
damage
and
debris.
If
the
quality
of
the
test
media
is
questionable,
replace
it
with
new
test
media.
4.
Load
the
test
media
into
the
drive.
Note:
For
the
preceding
step,
use
only
the
test
media;
do
not
substitute
with
other
media.
5.
Run
the
diagnostics
on
the
7212
Storage
Enclosure.
For
instructions,
refer
to
your
AIX
manuals.
Do
all
of
the
diagnostic
routines
pass?
NO
Exchange
the
FRU
isolated
by
the
diagnostics
and
identified
by
the
service
request
number.
Note:
If
the
drive
is
the
FRU
that
is
isolated
by
the
diagnostics,
check
that
the
connectors
are
properly
seated.
If
the
drive
has
recently
been
replaced
because
of
a
similar
problem,
contact
your
service
personnel.
YES
The
problem
is
fixed.
This
completes
the
MAPs
for
RS/6000
or
pSeries
host
systems.
Step
21
(AS/400
or
iSeries
Only)
You
are
here
because
the
host
system
is
an
AS/400
or
iSeries
host
system.
This
step
verifies
that
the
installed
devices
are
properly
configured
to
the
host
system.
1.
At
the
command
line
on
the
Main
Menu,
type
wrkcfgsts
then
press
Enter.
The
Work
with
Configuration
Status
display
appears.
2.
In
the
Type
field,
type
*dev
3.
In
the
Configuration
Description
field,
type
*tap
then
press
Enter
twice.
Does
the
device
that
you
are
configuring
appear
under
the
Description
column,
and
can
you
vary
it
on
and
off
successfully?
Note:
To
determine
the
number
of
the
device
that
you
are
configuring,
see
″
Performing
the
Checkout
Procedure,
″
in
the
7212
Model
102
Storage
Device
Enclosure
Setup
and
Operator
Guide
NO
Continue
with
Step
22
(AS/400
or
iSeries
Only).
YES
Go
to
Step
23.
Chapter
2.
Maintenance
Analysis
Procedures
23
Содержание 7212 102
Страница 2: ......
Страница 40: ...26 7212 Storage Device Enclosure Service Guide...
Страница 60: ...46 7212 Storage Device Enclosure Service Guide...
Страница 64: ...50 7212 Storage Device Enclosure Service Guide...
Страница 68: ...54 7212 Storage Device Enclosure Service Guide...
Страница 88: ...74 7212 Storage Device Enclosure Service Guide...
Страница 91: ......
Страница 92: ...Part Number 24R1295 Printed in USA SY44 0084 04 1P P N 24R1295...