Multi–Platform Interface Feature Operation Guide
61
6400-LU1-SCS-Remote SNA 3174 Control Unit
LU1-SCS mode is utilized when
neither
IPDS nor PSF
is needed to accomplish the
print function desired. An existing remote
3174 SNA-connected control unit is
assumed. The steps required to install a
remote LU1-SCS printer for host definitions
are as follows:
1.
Define to NCP, point to LU1 Logmode
entry defined below
2.
Define to VTAM by adding logmode
entry to VTAM Logmode Table
3.
Define to JES2 (May not be required if
VPS. See details below)
4.
Define to JES328X Print Facility, VPS,
or equivalent product.
5.
Select the options on the printer that
are appropriate for the environment.
Step 1 – NCP Definition
XYZ
GROUP
TYPE=NCP,...
LINK
ADDRESS=(032),...
REMPU74
PU
ADDR=C1,...
REM64XX
LU
LOCADDR=#,
(# replaced by port on control
unit)
DLOGMOD=64XXSCSR,(Default LOGMODE ENTRY NAME)
MODETAB=MYTABLE (Table name containing MODEENT)
*
Step 2 – VTAM Definition
*
The following entry should be placed in
the VTAM MODE TABLE specified above
or another of your choice.
64XXSCSR MODEENT LOGMODE=64XXSCSR,
FMPROF=X'03',TSPROF=X'03',PRIPROT=X'B1'
SECPROT=X'90',COMPROT=X'3080',RUSIZES=X'87C6',
PSERVIC=X'01000000E100000000000000',
PSNDPAC=X'01',SRCVPAC=X'01'
Содержание 6400 Series
Страница 1: ...S246 0149 03 6400 Line Matrix Printer Coax Twinax Multi Platform Interface Feature Operation Guide...
Страница 12: ...x...
Страница 83: ...Multi Platform Interface Feature Operation Guide 69 Appendix B Describing Custom Set 8 Printer Configuration 70...
Страница 89: ...hardware assemblies Multi Platform Interface Feature Operation Guide 75 Hardware Assemblies...
Страница 90: ...cable assemblies 76 Multi Platform Interface Feature Operation Guide Cable Assemblies...
Страница 91: ...cable assemblies Multi Platform Interface Feature Operation Guide 77...
Страница 109: ...coax character sets Multi Platform Interface Feature Operation Guide 95...
Страница 110: ...coax character sets 96 Multi Platform Interface Feature Operation Guide...