background image

Appendix

 

A.

 

Communications

 

Statements

 

The

 

following

 

statement

 

applies

 

to

 

this

 

product.

 

The

 

statement

 

for

 

other

 

products

 

intended

 

for

 

use

 

with

 

this

 

product

 

appears

 

in

 

their

 

accompanying

 

documentation.

 

Federal

 

Communications

 

Commission

 

(FCC)

 

Statement

 

Note:

  

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

A

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

when

 

the

 

equipment

 

is

 

operated

 

in

 

a

 

commercial

 

environment.

 

This

 

equipment

 

generates,

 

uses,

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instruction

 

manual,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

Operation

 

of

 

this

 

equipment

 

in

 

a

 

residential

 

area

 

is

 

likely

 

to

 

cause

 

harmful

 

interference

 

in

 

which

 

case

 

the

 

user

 

will

 

be

 

required

 

to

 

correct

 

the

 

interference

 

at

 

his

 

own

 

expense.

 

Properly

 

shielded

 

and

 

grounded

 

cables

 

and

 

connectors

 

must

 

be

 

used

 

in

 

order

 

to

 

meet

 

FCC

 

emission

 

limits.

 

Neither

 

the

 

provider

 

nor

 

the

 

manufacturer

 

is

 

responsible

 

for

 

any

 

radio

 

or

 

television

 

interference

 

caused

 

by

 

using

 

other

 

than

 

recommended

 

cables

 

and

 

connectors

 

or

 

by

 

unauthorized

 

changes

 

or

 

modifications

 

to

 

this

 

equipment.

 

Unauthorized

 

changes

 

or

 

modifications

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

this

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

European

 

Union

 

(EU)

 

Statement

 

This

 

product

 

is

 

in

 

conformity

 

with

 

the

 

protection

 

requirements

 

of

 

EU

 

Council

 

Directive

 

89/336/EEC

 

on

 

the

 

approximation

 

of

 

the

 

laws

 

of

 

the

 

Member

 

States

 

relating

 

to

 

electromagnetic

 

compatibility.

 

The

 

manufacturer

 

cannot

 

accept

 

responsibility

 

for

 

any

 

failure

 

to

 

satisfy

 

the

 

protection

 

requirements

 

resulting

 

from

 

a

 

non-recommended

 

modification

 

of

 

the

 

product,

 

including

 

the

 

fitting

 

of

 

option

 

cards

 

supplied

 

by

 

third

 

parties.

 

Consult

 

with

 

your

 

dealer

 

or

 

sales

 

representative

 

for

 

details

 

on

 

your

 

specific

 

hardware.

 

This

 

product

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

Class

 

A

 

Information

 

Technology

 

Equipment

 

according

 

to

 

CISPR

 

22

 

/

 

European

 

Standard

 

EN

 

55022.

 

The

 

limits

 

for

 

Class

 

A

 

equipment

 

were

 

derived

 

for

 

commercial

 

and

 

industrial

 

environments

 

to

 

provide

 

reasonable

 

protection

 

against

 

interference

 

with

 

licensed

 

communication

 

equipment.

  

Attention:

  

This

 

is

 

a

 

Class

 

A

 

product.

 

In

 

a

 

domestic

 

environment

 

this

 

product

 

may

 

cause

 

radio

 

interference

 

in

 

which

 

case

 

the

 

user

 

may

 

be

 

required

 

to

 

take

 

adequate

 

measures.

 

International

 

Electrotechnical

 

Commission

 

(IEC)

 

Statement

 

This

 

product

 

has

 

been

 

designed

 

and

 

built

 

to

 

comply

 

with

 

IEC

 

60950.

 

United

 

Kingdom

 

Telecommunications

 

Safety

 

Requirements

 

This

 

equipment

 

is

 

manufactured

 

to

 

the

 

International

 

Safety

 

Standard

 

EN60950

 

and

 

as

 

such

 

is

 

approved

 

in

 

the

 

UK

 

under

 

the

 

General

 

Approval

 

Number

 

NS/G/1234/J/100003

 

for

 

indirect

 

connection

 

to

 

the

 

public

 

telecommunication

 

network.

 

The

 

network

 

adapter

 

interfaces

 

housed

 

within

 

this

 

equipment

 

are

 

approved

 

separately,

 

each

 

one

 

having

 

its

 

own

 

independent

 

approval

 

number.

 

These

 

interface

 

adapters,

 

supplied

 

by

 

the

 

manufacturer,

 

do

 

not

 

use

 

or

 

contain

 

excessive

 

voltages.

 

An

 

excessive

 

voltage

 

is

 

one

 

which

 

exceeds

 

70.7

 

V

 

peak

 

ac

 

or

 

120

 

V

 

dc.

 

They

    

27

Содержание 5710

Страница 1: ...PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide SA23 1303 02...

Страница 2: ......

Страница 3: ...PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide SA23 1303 02...

Страница 4: ...g this information and the product it supports read the information in Safety Information on page v and Appendix B Notices on page 31 International Business Machines Corporation 2003 2004 All rights r...

Страница 5: ...ices 10 Chapter 5 Setting Up the PCI X Dual Channel Ultra320 SCSI Adapter AIX 11 Verifying the Installation 11 Verifying AIX Software Installation 11 Verifying Hardware Installation 11 Updating Hard D...

Страница 6: ...an Union EU Statement 27 International Electrotechnical Commission IEC Statement 27 United Kingdom Telecommunications Safety Requirements 27 Avis de conformit aux normes du minist re des Communication...

Страница 7: ...and all attached devices are unplugged When adding or removing any additional devices to or from the system ensure that the power cables for those devices are unplugged before the signal cables are co...

Страница 8: ...vi PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 9: ...ssibly damage the device v While the device is still in its antistatic package touch it to an unpainted metal part of the system unit for at least two seconds This drains static electricity from the p...

Страница 10: ...viii PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 11: ...ntains references to the AIX and Linux operating system If you are using another operating system consult the appropriate documentation for that operating system This document may describe hardware fe...

Страница 12: ...x PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 13: ...tly with external LVD low voltage differential subsystems internal LVD devices or external SE single ended devices see Appendix C Connecting SCSI Devices to the Adapter on page 33 None of these config...

Страница 14: ...ternally attached devices on the same channel is not supported with this adapter The following figure shows the external and internal channels Note The adapter has built in SCSI terminators on each ch...

Страница 15: ...ss is http techsupport services ibm com server support Updates can also be ordered by calling IBM Support Using Linux The PCI X Dual Channel Ultra320 SCSI Adapter is supported on the following Linux d...

Страница 16: ...4 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 17: ...igh density plastic D shell connector This connector joins to a VHDCI to P shell converter cable which plugs into the adapter External Cable Lengths SCSI specifications limit the total cable length at...

Страница 18: ...cs CD ROM Version 5 2 0 11 or higher v Flat blade screwdriver Using AIX In addition to the preceding items listed you will need the following AIX specific items v AIX 5 1 Update CD ROM Recommended Mai...

Страница 19: ...ilable Software screen appears and highlights the INPUT Device directory for software option 6 Select or type the input device using one of the following methods v Press F4 to display the input device...

Страница 20: ...18 Press F10 to exit SMIT 19 Go to Chapter 4 Installing the PCI X Dual Channel Ultra320 SCSI Adapter Hardware AIX on page 9 8 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 21: ...tly Connecting External or Internal Devices To connect external or internal devices use the following procedures Note Attachment cables are usually shipped with the attaching subsystem or device Conne...

Страница 22: ...tem drive or backplane 2 Connect the adapter end of the cable to the correct internal connector on the PCI X Dual Channel Ultra320 SCSI Adapter Use either connector Channel 0 J2 or Channel 1 J3 3 When...

Страница 23: ...hannel Ultra320 SCSI Adapter device software is installed the following is an example of the data that displays on your screen devices pci 14106602 diag 5 2 0 11 COMMITTED PCI X Dual Channel Ultra320...

Страница 24: ...of the drive you are updating can be identified by reading its VPD Vital Product Data Similarly the name of the PCI X Dual Channel Ultra320 SCSI Adapter Microcode download you need can be found under...

Страница 25: ...ct Apply change to DATABASE only 2 Press F4 and select yes 3 Press Enter 4 Press F10 to exit SMIT 5 At this point the adapter and its child devices must be reconfigured To reboot your system log in as...

Страница 26: ...14 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 27: ...ou are using the ipr device driver Note If you are using AIX follow the steps in Chapter 4 Installing the PCI X Dual Channel Ultra320 SCSI Adapter Hardware AIX on page 9 Attention Do not remove the PC...

Страница 28: ...To verify the version number of ipr do the following For 2 6 Linux kernels 1 If necessary log in as root user 2 Type modinfo ipr grep version Press Enter The following is an example of the data that d...

Страница 29: ...Web site http www 124 ibm com storageio ipr After downloading the needed software package install the software by continuing with the instructions in this section Then return to Verifying Linux Softw...

Страница 30: ...hannel Ultra320 SCSI Adapter installed correctly data displays for the adapter and each disk attached to it The following is an example of the data that displays on your screen Display Hardware Status...

Страница 31: ...d you are finished If you are using a 2 6 based kernel type iprconfig Press Enter and go to the next step 4 If you are using a 2 6 based kernel choose the Download microcode menu option and v Select t...

Страница 32: ...f these options may not be available 7 Press Enter to continue 8 Press c to confirm the changes Wide Bus Enabled If you are attaching an external device with an 8 bit SCSI interface cable set Wide ena...

Страница 33: ...ng a Some systems support the hot plugging of adapters If supported prepare your system to hot plug this adapter while system power is on Shut down your system unit if your system does not support hot...

Страница 34: ...nel Ultra320 SCSI Adapter requires Version 1 Revision 19 or later of the sisconfig utility To verify the version number of the sisconfig utility do the following 1 If necessary log in as root user 2 T...

Страница 35: ...see the readme file located in the sisutils directory Verifying Hardware Installation To verify that your system unit recognizes the PCI X Dual Channel Ultra320 SCSI Adapter do the following 1 If nece...

Страница 36: ...microcode Type make install 5 Update the microcode Type sisupdate Press Enter Configuring the PCI X Dual Channel Ultra320 SCSI Adapter The PCI X Dual Channel Ultra320 SCSI Adapter permits up to 320 MB...

Страница 37: ...your hardware some of these options may not be available 7 Press Enter to continue 8 Press c to confirm the changes Wide Bus Enabled If you are attaching an external device with an 8 bit SCSI interfac...

Страница 38: ...26 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 39: ...esired operation European Union EU Statement This product is in conformity with the protection requirements of EU Council Directive 89 336 EEC on the approximation of the laws of the Member States rel...

Страница 40: ...s A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may a...

Страница 41: ...n oder des Bundesamtes f r Post und Telekommunikation betrieben werden Die Genehmigung wird erteilt wenn keine elektromagnetischen St rungen zu erwarten sind Auszug aus dem EMVG vom 9 Nov 92 Para 3 Ab...

Страница 42: ...30 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 43: ...untry where such provisions are inconsistent with local law THIS MANUAL IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES O...

Страница 44: ...32 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 45: ...l on the adapter has a terminator that is automatically enabled when a cable is attached to either the external or internal connector The PCI X Dual Channel Ultra320 SCSI Adapter does not support simu...

Страница 46: ...be used to attach VHDCI connectors on the adapter and P shell connector on external cables The terminator may be built into the last device or it may be externally attached A Adapter C Converter cabl...

Страница 47: ...ystems might also split the buses For details see your subsystem documentation In subsystems that have drives shared between two systems each port of the subsystem is connected to a different SCSI ada...

Страница 48: ...36 PCI X Dual Channel Ultra320 SCSI Adapter Installation and Using Guide...

Страница 49: ...DB 13 2 36 DB 13 Ground DB 14 3 37 DB 14 Ground DB 15 4 38 DB 15 Ground DB P1 5 39 DB P1 Ground DB 0 6 40 DB 0 Ground DB 1 7 41 DB 1 Ground DB 2 8 42 DB 2 Ground DB 3 9 43 DB 3 Ground DB 4 10 44 DB 4...

Страница 50: ...ould tie the following signals inactive high DB 8 DB 9 DB 10 DB 11 DB 12 DB 13 DB 14 DB 15 DB P1 and float the same signal lines v 8 bit LVD devices or SE mode the following signals must be tied inact...

Страница 51: ......

Страница 52: ...Part Number 80P5520 Printed in USA SA23 1303 02 1P P N 80P5520...

Отзывы: