background image

 

10

Remote access to the command line interface 

From any computer on the same network as the Network Management Card, you can use ARP and Ping to assign an IP address to the 
Network Management Card, and then use Telnet to access its command line interface and configure the other TCP/IP settings. 

Note:

 After the Network Management Card has its IP address configured, you can use Telnet, without first using ARP and Ping, to 

access that Network Management Card. 

1.

 

Use the MAC address of the Network Management Card in the ARP command to define the IP address.  

Note:

 Look for the MAC address on the bottom of the Network Management Card or on the Quality Assurance slip included in the 

package. 

For example, to define 156.205.14.141 as the IP address of a Network Management Card with 00 c0 b7 63 9f 67 as its MAC address, 
use one of the following commands: 

 

Windows command format: 

arp -s 156.205.14.141 00-c0-b7-63-9f-67

 

 

LINUX command format: 

arp -s 156.205.14.141 00:c0:b7:63:9f:67 

 

2.

 

Use Ping with a size of 113 bytes to assign the IP address defined by the ARP command. For the IP address defined in step 1, 
use one of the following commands:  

 

Windows command format: 

ping 156.205.14.141 -l 113

 

 

LINUX command format: 

ping 156.205.14.141 -s 113 

3.

 

Use Telnet to access the Network Management Card at its newly assigned IP address. For example: 

telnet 156.205.14.141

 

4.

 

Use apc for both user name and password. 

See “Command line interface” on page 10 to finish the configuration. 

Command line interface 

After you log on at the command line interface, as described in “Local access to the command line interface” on page 13 or “Remote 
access to the command line interface” on page 10, you can manually configure network settings. 

1.

 

Contact your network administrator to obtain the IP address, subnet mask, and default gateway for the Network Management 
Card.  

2.

 

Use these three commands to configure network settings. (Text in italics indicates a variable.) 

a.

  tcpip -i yourIPaddress  

b.

  tcpip -s yourSubnetMask  

c.

 tcpip 

-g 

yourDefaultGateway 

 

For each variable, type a numeric value that has the format 

xxx.xxx.xxx.xxx

 

For example, to set a system IP address of 156.205.14.141, type the following command and press Enter:

  

tcpip -i 156.205.14.141 

Type 

exit

. The Network Management Card restarts to apply the changes. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 5000XHV

Страница 1: ...Supply Operation and Setup Guide for information on how to obtain service and support for the unit NOTE Illustrations in this document might vary in appearance from the purchased unit Utility knife or scissors Two Phillips screwdrivers 1 and 2 One wrench 10mm Cage nut insertion tool or flat blade screwdriver for installing cage nuts in some rack cabinets Inventory Quick Installation Guide Importan...

Страница 2: ... Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate Connect any equipment that will be attached to this product to properly wired outlets When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunication...

Страница 3: ...emoving the UPS from the shipping carton or installing or removing the UPS in the rack D007 CAUTION Energy hazard present Shorting might result in system outage and possible physical injury Remove all metallic jewelry before servicing C001 CAUTION Lead acid batteries can present a risk of electrical burn from high short circuit current Avoid battery contact with metal materials remove watches ring...

Страница 4: ... uninterruptible power supply Y Refer to the instruction sheet included in the rail kit for rail installation details Refer to the diagram below for cage nut clip nut installation The solid squares indicate the cage nut clip nut locations Install the uninterruptible power supply at the bottom of the rack Note Leave 3 U of space below the uninterruptible power supply for each battery pack to be ins...

Страница 5: ...sical injury Remove all metallic jewelry before servicing C001 X Open the battery compartment door Y Install the battery modules Z Connect the battery modules Close the battery compartment door Be sure the battery cables are positioned so that they are not pinched Secure the battery compartment door using the screws removed previously Attach the bezel ...

Страница 6: ...zed from a remote location without switching to battery operation See Emergency Power Off EPO Option Network Management Card The Network Management Card NMC is factory installed in the uninterruptible power supply Link RX TX 10 100 LED Refer to the NMC documentation for details Status LED Refer to the NMC documentation for details Reset on the NMC Resets the NMC while the unit is connected to util...

Страница 7: ...fications for uninterruptible power supply or system events Limits SNMP traps and e mail notifications based on the severity level of the events Provides tools to configure one or more Network Management Cards over the network Provides enhanced security To configure the pre installed Network Management Card of your uninterruptible power supply using this network interface option refer to Chapter 3...

Страница 8: ... Management Cards 1 If autorun is enabled the user interface of the CD starts when you insert the APC Network Management Card Utility CD into a computer on your network Otherwise open the file contents htm on the CD 2 Select the Device IP Configuration Wizard from the main menu 3 When the Wizard discovers the unconfigured Network Management Card follow the on screen instructions Note If you leave ...

Страница 9: ...Management Card A User Class Identifier by default the identification of the application firmware installed on the Network Management Card 2 A properly configured DHCP server responds with a DHCP offer that includes all the settings that the Network Management Card needs for network communication The DHCP offer also includes the Vendor Specific Information option DHCP option 43 By default the Netw...

Страница 10: ... defined by the ARP command For the IP address defined in step 1 use one of the following commands Windows command format ping 156 205 14 141 l 113 LINUX command format ping 156 205 14 141 s 113 3 Use Telnet to access the Network Management Card at its newly assigned IP address For example telnet 156 205 14 141 4 Use apc for both user name and password See Command line interface on page 10 to fini...

Страница 11: ... name if configured 3 Enter the User Name and Password apc by default For SNMP use a MIB Browser and the supplied MIB to monitor and configure the Network Management Card of the uninterruptible power supply through SNMP When using high security access disable SNMP Note For more information about how to use any of these interfaces and about how to configure high security access see the User s Guide...

Страница 12: ...BE package the user can install just the Agent component for a simpler monitoring system INSTALLING POWERCHUTE BUSINESS EDITION The user can install all three PCBE components on the same computer or on different computers on the network The PCBE Agent component however must be installed on a computer that is connected to an uninterruptible power supply with the supplied serial cable For Windows Op...

Страница 13: ...ssible to install PCBE Agents after the initial installation These Agents can be added to the device list of any PCBE Server that uses the same password and user name Follow these steps 1 Use PCBE Console to log on to the PCBE Server 2 Select Configure Device List from the Tools menu 3 Highlight a PCBE Agent to be added in the Discovered Devices list and click Add 4 Repeat step 3 for each PCBE Age...

Страница 14: ...gs are 9 bits per second 9600 9 data bits 8 9 parity none 9 stop bit 1 9 flow control none c Click Enter 5 Once the blank terminal window is open follow these steps to configure the output voltage a Press Enter to initiate terminal mode b Press 1 to select uninterruptible power supply Settings Wait for the uninterruptible power supply Settings menu to appear on the screen c Press 1 to select Outpu...

Отзывы: