2. If you are installing a new power supply into an empty power supply bay,
remove the two screws near the edges of the cover plate to unlock the plate,
then remove the plate.
3. Remove the new power supply from its packaging.
4. With one hand, hold the front end of the power supply. With the other hand,
support the underside of the power supply, and insert the power supply into the
empty power supply slot. Press until the supply is completely in the slot, so that
the connectors on the back of the supply are fully engaged with the pins on the
power backplane.
Attention:
Make sure you insert the power supply right-side up. It is possible
to insert the supply upside down, although the supply will not engage with the
power backplane when upside down. The power supply is right-side up when
the power connector is on the left and the fan vent is on the right. All references
to right-side and left-side are referenced from looking at the device from the
front.
5. Secure the two screws near the edges of the supply to lock the supply in place.
6. Connect the power cord to the power supply.
7. Connect the plug end of the power cord into an outlet.
CAUTION:
For the NEBS compliant installation of c-series switches with AC system
use a ground wire of at least 8 American Wire Gauge (AWG). The ground
wire should have an agency-approved crimped connector (provided with
the chassis) attached to one end, with the other end attached to building
ground. The connector must be crimped with the proper tool, allowing it to
be connected to both ground screws on the enclosure. Before crimping
the ground wire into the provided ground lug, insure the bare copper wire
has been cleaned and antioxidant is applied to the bare wire.
Installing the device
You can install the system on a desktop, or in an equipment rack.
Desktop installation
1. Set the device on a flat desktop, table, or shelf. Make sure that adequate
ventilation is provided for the system; a 3-inch clearance is recommended on
each side.
2. Go to “Powering on the system” on page 19.
Rack mount installation
For rack mount installation, use the rack mount ears attached to the unit. Each unit
ships with rack ears attached to the front of the unit. You can mount the rack ears
in 4 different locations on the device.
Note:
When attaching the chassis to the rack, use star washers to provide
grounding of the chassis to the rack. If any single-hole grounding lugs are
used, star washers must be used to prevent rotation of the lug.
Forward rack mount position
The c-series switches ship with the rack ears attached to the front of the device as
shown in figure Figure 10 on page 15. Alternative mounting positions for the rack
mount ears are shown in figures Figure 11 on page 16, Figure 12 on page 17 and
Figure 13 on page 18.
14
IBM Ethernet Switch c-series Installation and User Guide
Содержание 4002-C4A
Страница 2: ......
Страница 8: ...vi IBM Ethernet Switch c series Installation and User Guide ...
Страница 10: ...viii IBM Ethernet Switch c series Installation and User Guide ...
Страница 12: ...x IBM Ethernet Switch c series Installation and User Guide ...
Страница 26: ...2 IBM Ethernet Switch c series Installation and User Guide ...
Страница 37: ...net48bc013 Figure 8 AC power supply net48bc014 Figure 9 Power supply installation Chapter 3 Installation 13 ...
Страница 39: ...net48bc017 Figure 10 Front rack mount position Chapter 3 Installation 15 ...
Страница 41: ...net48bc019 Figure 12 Mid rack mount position Chapter 3 Installation 17 ...
Страница 60: ...36 IBM Ethernet Switch c series Installation and User Guide ...
Страница 68: ...44 IBM Ethernet Switch c series Installation and User Guide ...
Страница 82: ...58 IBM Ethernet Switch c series Installation and User Guide ...
Страница 93: ......
Страница 94: ... Part Number 45W3139 Printed in USA GC27 2238 00 1P P N 45W3139 80218 001 ...