 2006 Model L10 Fixed Rack-Mount Kit Instructions

5

6.  Install the cover panel (see Figure 3).

a.  Align the cover panel’s 

 mounting holes with the empty center holes in the 

equipment rack’s rear rails.

b.  Securely fasten the cover panel to the equipment rack’s rear rails using one hex 

screw 

 for each side. The cover panel will conceal the tray assembly’s top and 

bottom hex screws in both of the equipment rack’s rails.

7.  Provide power to the switch.

a.  Insert the included power cord into the Model L10 switch and connect it to a power 

outlet.

Refer to the switch’s

 

User’s Guide for the proper procedure on powering on the 

switch.

Figure 3.  Installing the cover panel on the back side of the tray assembly

l100040

7

5

Содержание 26K7918

Страница 1: ...w the Guidelines for Mounting Equipment in a Rack section Guidelines for Mounting Equipment in a Rack When installing IBM Corporation equipment in a rack give careful consideration to the following factors The operating ambient temperature of rack mounted equipment must not exceed the maximum rated ambient temperature which is indicated in the product installation guide The air flow clearances spe...

Страница 2: ...shown in Figures 2 and 3 respectively Note The rack mount tray must be mounted using the 5 8 inch gap intervals The tray assembly will not mount properly using the 1 2 inch interval At least 1U of vertical space is necessary to accommodate the rack mount tray assembly Table 1 Parts supplied with the Model L10 fixed rack mount kit Part Description Quantity Rack mount tray assembly 1 Rear mounting r...

Страница 3: ...k c Repeat steps 3a and 3b for the remaining rear mounting rail 4 Mount the rack mount tray assembly in the equipment rack see Figure 1 a Align the rack mount tray assembly with the installed rear mounting rails b Slowly insert the tray assembly into the equipment rack and the rear mounting rails c Ensure that the front mounting rails insert properly into the rear mounting rails The rear mounting ...

Страница 4: ...ay until the metal tab is inserted in the slot c Insert the stop bracket s metal tab into the slot on the outer side of the switch d Pivot the stop bracket until the stop bracket lays flat against the equipment rack s front rail see Figure 2 e Align the stop bracket with the center hole in the equipment rack s front rail f Attach the stop bracket to the equipment rack s front rail using one hex sc...

Страница 5: ... rear rails using one hex screw for each side The cover panel will conceal the tray assembly s top and bottom hex screws in both of the equipment rack s rails 7 Provide power to the switch a Insert the included power cord into the Model L10 switch and connect it to a power outlet Refer to the switch s User s Guide for the proper procedure on powering on the switch Figure 3 Installing the cover pan...

Страница 6: ...express or implied warranties in certain transactions therefore this statement may not apply to you Order publications through your IBM representative or the IBM branch office serving your locality Copyright International Business Machines Corporation 2004 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp 2...

Отзывы: