© Copyright IBM Corp. 2004

1

IBM TotalStorage Storage Switch

2006 Model L10 Fixed Rack-Mount Kit Instructions

IBM Corporation offers this optional, fixed rack-mount kit for the IBM TotalStorage® 
Storage Switch 2006 Model L10. This kit includes the necessary hardware to install one 
or two switches into any standard 19-inch equipment rack.

Caution:  The fixed rack-mount kit is not designed to withstand the shock and vibration 
forces that may result from shipping an installed rack-mount kit and switch unit(s) in an 
equipment rack. IBM Corporation recommends installing the rack-mount kit and switch 
unit(s) in an equipment rack at the designated location where the equipment rack will 
reside. IBM Corporation is not responsible for any injury or damage that may result from 
improper installation or unintended use of this rack-mount kit. If you want the Model L10 
switch pre-installed, using the shippable shelf rack-mount kit, contact an IBM 
Corporation sales representative.

Before installing the fixed rack-mount kit, review the Guidelines for Mounting Equipment 
in a Rack s
ection.

Guidelines for Mounting Equipment in a Rack

When installing IBM Corporation equipment in a rack, give careful consideration to the 
following factors:

•  The operating ambient temperature of rack-mounted equipment must not exceed the 

maximum rated ambient temperature, which is indicated in the product installation 
guide.

•  The air flow clearances specified in the product installation guide must be maintained 

within the rack.

•  The AC supply circuit for rack-mounted equipment must be capable of supplying the 

total current specified on all the labels of the rack-mounted equipment.

•  All AC power supply connections must be properly grounded (earthed). To ensure the 

integrity of the grounded connection, special attention must be given to connections 
that are not directly connected to the branch circuit (for example, power strips).

•  The rack-mounting hardware provided for IBM Corporation equipment has been 

carefully selected to adequately support the equipment. Any alternate rack-mounting 
hardware must provide equal or superior support.

•  Plan the device installation starting from the bottom of the rack cabinet. Install the 

heaviest device in the bottom of the rack cabinet.

Содержание 26K7918

Страница 1: ...w the Guidelines for Mounting Equipment in a Rack section Guidelines for Mounting Equipment in a Rack When installing IBM Corporation equipment in a rack give careful consideration to the following factors The operating ambient temperature of rack mounted equipment must not exceed the maximum rated ambient temperature which is indicated in the product installation guide The air flow clearances spe...

Страница 2: ...shown in Figures 2 and 3 respectively Note The rack mount tray must be mounted using the 5 8 inch gap intervals The tray assembly will not mount properly using the 1 2 inch interval At least 1U of vertical space is necessary to accommodate the rack mount tray assembly Table 1 Parts supplied with the Model L10 fixed rack mount kit Part Description Quantity Rack mount tray assembly 1 Rear mounting r...

Страница 3: ...k c Repeat steps 3a and 3b for the remaining rear mounting rail 4 Mount the rack mount tray assembly in the equipment rack see Figure 1 a Align the rack mount tray assembly with the installed rear mounting rails b Slowly insert the tray assembly into the equipment rack and the rear mounting rails c Ensure that the front mounting rails insert properly into the rear mounting rails The rear mounting ...

Страница 4: ...ay until the metal tab is inserted in the slot c Insert the stop bracket s metal tab into the slot on the outer side of the switch d Pivot the stop bracket until the stop bracket lays flat against the equipment rack s front rail see Figure 2 e Align the stop bracket with the center hole in the equipment rack s front rail f Attach the stop bracket to the equipment rack s front rail using one hex sc...

Страница 5: ... rear rails using one hex screw for each side The cover panel will conceal the tray assembly s top and bottom hex screws in both of the equipment rack s rails 7 Provide power to the switch a Insert the included power cord into the Model L10 switch and connect it to a power outlet Refer to the switch s User s Guide for the proper procedure on powering on the switch Figure 3 Installing the cover pan...

Страница 6: ...express or implied warranties in certain transactions therefore this statement may not apply to you Order publications through your IBM representative or the IBM branch office serving your locality Copyright International Business Machines Corporation 2004 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp 2...

Отзывы: