Parameter
Description
op_mode
Default operation mode for the Network Active Bypass
unit
v
0: Normal Active Bypass
If heartbeat is received, system will be inline.
v
1: Normal Active Inline
If heartbeat is received, system will be in bypass.
v
2: Manual Active
v
3: Manual Active Bypass
v
4: Manual Passive Bypass (Bypass Switch is closed in
bypass mode)
Default: 0 (Normal Active Bypass)
hb_mode
Heartbeat mode for the Network Active Bypass unit
v
hb_mode 1: system is generating heartbeat
v
hb_mode 2: external source is generating heartbeat
v
hb_mode 3: system activates bypass depending on link
detection on the appliance
Default: hb_mode 1
state
State of the Network Active Bypass unit
This parameter is read-only.
v
0: Bypass Switch state
v
1: Active/Inline Switch state
active_hb_cnt
Stores the active heartbeat signal count
The segment switches to Active Switch mode only if it
receives active_hb_cnt number for a consecutive
heartbeat.
Default: 2 (Range: 1 - 10)
bypass_hb_cnt
Stores the bypass heartbeat signal count
The segment will switch to Bypass Switch mode only if it
loses bypass_hb_cnt heartbeat signal number.
Default: 3 (Range: 1 - 10)
parameters
Use the following parameters to configure from the CLI:
Parameter
Description
tacacs
Values:
v
0: disabled
v
1: enabled
tacacs_encryption
Values:
v
0: disabled
v
1: enabled
tacacs_protocol
protocol
Default: all
26
1G Network Active Bypass: User Guide
Содержание 1G
Страница 1: ...IBM Security 1G Network Active Bypass User Guide ...
Страница 4: ...iv 1G Network Active Bypass User Guide ...
Страница 6: ...vi 1G Network Active Bypass User Guide ...
Страница 16: ...xvi 1G Network Active Bypass User Guide ...
Страница 28: ...10 1G Network Active Bypass User Guide ...
Страница 46: ...28 1G Network Active Bypass User Guide ...
Страница 50: ...32 1G Network Active Bypass User Guide ...
Страница 51: ......
Страница 52: ... Printed in USA ...