Getting Started
21
2.5 Partially Populated Enclosure
If the enclosure is not fully populated, it is recommended to load the drive columns and not rows for
maximum performance, (
).
2.6 EBOD Module Installation
Warning
Operation of the Enclosure with
ANY
modules missing will disrupt the airflow and the drives will
not receive sufficient cooling. It is
ESSENTIAL
that all apertures are filled before operating the
unit. Dummy Carriers are available for this purpose.
2.6.1 Parts Check List
2 EBOD Modules
2.6.2 Installation Procedure
Check for damage especially to the interface connector, do not install if any pins are bent.
1
The modules should be installed in rear bays 3 and 4 of the Enclosure (
).
2
With the latch in the open position (
), slide the EBOD module into the enclosure until the latch
engages automatically.
Figure 2–8
Partially Populated Enclosure
Figure 2–9
Module Latch Operation
Содержание 1269-3S2
Страница 35: ...Getting Started 19 Figure 2 6 DCS9900 to 10 Enclosures 1 x 16 Configuration Singlet View...
Страница 76: ......
Страница 77: ...Printed in USA GA32 0613 00...