IBM System Storage DCS9900 1269-3S2 Storage Expansion Unit Installation, Service, and User Guide
36
4.3.2 Ops Panel
The Ops Panel displays the aggregated status of all the modules. The Ops Panel LEDs are shown in
and defined in
.
Note
The Ops Panel is supplied as an integral part of the Enclosure core product and is not user replaceable.
Figure 4–2
Ops Panel
Table 4–2
Ops Panel LEDs
Ops Panel LEDs
Powe
r (Gre
en
PSU/Coo
lin
g/
Temp (A
mbe
r)
Sy
stem (Amb
er)
Other Associated LEDs
or Alarms
State Description
On
Off
Off
Power On, enclosure ready
On
On
On
Single beep, then double beep Ops panel power on (5s) test state
On
On
Off
PSU LEDs or Fan LEDs
intermittent audible alarm
Any PSU fault or Fan fault
On
On
Flash
intermittent audible alarm
Over or under temperature
On
Off
On
LED on EM
Processor on EBOD Module A failed
On
Off
On
LED on EM
Processor on EBOD Module B failed
On
Off
On
None
Unknown (invalid or mixed) module type
installed, or 12C bus failed
On
Flash
Flash
PSU removed
PSU removed and system power redundancy
check option set. no indication if option not set.
On
Flash
On
intermittent audible alarm
Ops to EBOD Module communications failed