© Copyright LOTRONIC 2017
PAR-MINI-STR
4
DMX Channels
CH
VALUE
FUNCTION
1
0~255
Master dimmer
2
0~255
R dimmer
3
0~255
G dimmer
4
0~255
B dimmer
5
0~255
W dimmer
6
0~255
Strobe function selection
0~99
Par & Strobe Light flash at the same time
100~199
Par Light flash
200~255
Strobe Light flash
7
0~9
No Strobe
10~255
Value +, Strobe speed
-
8
0~50
Manual Mode, Available from CH1
-
CH7
51~100
Jump chan
ge, Same as 'FF**' mode, CH6 adjust speed
101~150
Gradual change, Same as 'CC**' mode, CH6 adjust speed
151~200
Pulse change, Same as 'EE**' mode, CH6 adjust speed
201~250
Auto Mode
251~255
Sound Mode
DMX Connection
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always
advisable to connect a DMX signal terminator.
Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Input voltage: ................................................................................ AC100
~
240V 50/60H
z
Consumption ................................................................................................................. 15W
INPUT
COMMON
DMX +
DMX-
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3 (DMX+)
of the last fixture.