background image

 

DIP number 

Function description 

remark 

10+1 R 
10+2 G 
10+3 B 
10+2+1 R+G 
10+3+1 R+B 
10+3+2 G+B 
10+3+2+1 R+G+B 

 
 
 
Fixed color (away brightness) 

10+8 Auto 

running 

Auto running show(include shade. strobe. change 
color and so on) 

10+8+1 R 

shade 

10+8+2 G 

shade 

10+8+3 B 

shade 

10+8+2+1 

RGB shade speed 1 fast  

10+8+3+1 

RGB shade speed 2

 

10+8+3+2 

RGB shade speed 3 slow  

10+8+3+2+1 R+G+B 

shade 

              
 
 
Shade 
 
 

10+9 

RGB change each other 

 

10+9+1 R 

strobe 

10+9+2 G 

strobe 

10+9+3 B 

strobe 

10+9+4 R+B 

strobe 

10+9+5 R+G 

strobe 

10+9+6 G+B 

strobe 

 
 
Strobe 

10+9+2+1 

R+G+B strobe(speed 
adjustment) 

(DIP3-DIP7) adjustment strobe speed 

10+7 Sound 

control1 

 

10+7+1 Sound 

control2 

 

10+7+2 Sound 

control3 

 

10+7+3 Sound 

control4 

 

10+7+4 Sound 

control5 

 

10+7+5 Sound 

control6 

 

 

Appendix 

1. Usage of the Signal Cable. Connector 
The connection between the output and input, it’s available to use the 3 pins XLR cable which provided by the 
manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, and connect 
to the DMX input of second slave light from the DMX output of the first master light, analogously till connected all 
the slave lights, and insert the last connector to the output of the final light. 
If you want to prolong the connection of signal cable, the connection of the pins between male connector and 
female connector should be:1 to 1; 2 to 2; 3 to 3,or it will cause communication interruption. Notice: the diameter 
of core of every cable should be 0.5mm at least double core shelter cable should be used. The signal connecting 
must use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch 
to each other or connect to the connector. 
The light is available to receive the DMX512 signal, connect the signal plug to the panel which marked with “IN” 
and connect it to the next light. then, connect to the “IN” of next light from the “OUT”. The DMX signal terminal 
organ is recommended when the lighting signal is connecting. It will avoid to damage the signal which caused by 
the noise, DMX terminal organ is a XLR connector, connect with a 120

 resistor between the pin 2 and pin 3 of 

the XLR connector, and connect it to the last OUTPUT socket of the final light. Follow picture: 
 

© Copyright Lotronic 2009 

5

1

st

 light 

2

n

d

 light 

3

rd

lig

ht

 

IN OUT 

IN 

 

OUT 

IN

OUT 

 
 
 
 

DMX 

 
 
 
 
 

 

 

120R 

Содержание MUSHROOM-LED (15-1084)

Страница 1: ...Copyright Lotronic 2009 1 L LE ED D M MU US SH HR RO OO OM M E EF FF FE EC CT T GB INSTRUCTION MANUAL F MANUEL D UTILISATION D BEDIENUNGSANLEITUNG Mod MUSHROOM LED 15 1084...

Страница 2: ...evice for indoor use only The protection grade is IP20 The light must keep dry and avoid to use under the Moist Overheat or Dusty surroundings And keep the light far away from the water or other liqui...

Страница 3: ...follows Voltage AC220V 240V Frequency 50Hz Voltage AC110V 240V Frequency 60Hz If the power cable is damaged please contact the area agents or ask professional to replace please use the same specifica...

Страница 4: ...P number Function description Remark 10 8 Auto Auto running show include shade strobe change color and so on 10 8 1 R shade 10 8 2 G shade 10 8 3 B shade 10 8 2 1 RGB shade speed1fast 10 8 3 1 RGB sha...

Страница 5: ...tput of the first master light analogously till connected all the slave lights and insert the last connector to the output of the final light If you want to prolong the connection of signal cable the...

Страница 6: ...agenta 120 136 Cyan 137 153 Red shade 154 170 Green shade 171 187 Blue shade 188 204 White shade 205 221 Color shade 222 238 RGB Swat change CH5 Fixed color shade 239 255 RGB shade Shading can be adju...

Страница 7: ...te fuse and start the light after find out troubleshooting but please attention to the technically person allowed to carry out maintenance work Faulty Disposal Familiar Faulty Disposal Light can not s...

Страница 8: ...doit se situer entre 15 C et 45 C L appareil peut atteindre des temp ratures allant jusqu 130 C Ne jamais toucher le bo tier L appareil doit tre branch imp rativement sur une prise de terre Ne jamais...

Страница 9: ...mutateur Description de la fonction Observation 10 8 Automatique Fonctionnement automatique comprenant teinte stroboscope changement de couleur etc 10 8 1 Teinte rouge 10 8 2 Teinte vert 10 8 3 Teinte...

Страница 10: ...effet est pr vu pour le format DMX512 Si vous branchez plusieurs effets l un la suite de l autre il faut mettre une r sistance de fin de ligne de 120 Ohms entre les broches 2 3 sur la sortie XLR du d...

Страница 11: ...prolonger sa dur e de vie Ne pas utiliser d alcool ou de d tergents pour nettoyer l appareil Nettoyez l appareil au moins une fois par an l aide d un aspirateur 11 En cas de panne Probl me Solution L...

Страница 12: ...deren Gegenst nden muss mindestens 1m betragen Der Mindestabstand zwischen dem Ger t und brennbaren Gegenst nden muss mindestens 2m betragen Die Raumtemperatur muss zwischen 15 und 45 C liegen Das Ger...

Страница 13: ...r verschiedenen Betriebsarten im Automatikbetrieb Schalternr Beschreibung der Funktion Bemerkung 10 8 Automatik Automatikbetrieb mit Farbabstufung Blitzleuchte Farbwechsel usw 10 8 1 Rotabstufung 10 8...

Страница 14: ...chster Qualit t um eine einwandfreie bertragung des DMX Signals zu gew hrleisten Copyright Lotronic 2009 14 DMX Ausgang DMX Eingang Das Ger t ist f r das Protokoll DMX512 ausgelegt Wenn Sie mehrere Ge...

Страница 15: ...Ger ts dient nicht nur zur Erhaltung der vollen Lichtausbeute sondern verl ngert auch erheblich die Lebenserwartung Keinen Alkohol oder andere chemische Reinigungsmittel verwenden Reinigen Sie das Ger...

Отзывы: