Electrical & Automation

Preset Digital Counter

IBEST ELECTRICAL CO.,LTD

 CRN SERIES

Press “RST” 

key for 3s

Select the counting frequency: 30, 300, 1000, 3000(Hz),press “    ” to select

Input mode: In-A,In-B (Press “    ” to selsect)

Output mode: N,F,C,A (Press “    ” to selsect)

a. Operation menu:

b. Convert displaying set value:

 on the faceplate, “SET2” lamp  “ON” means the displaying value is comparing output set value,“SET1” lamp “ON” means 

     counting value. Simply press “     ” key to convert set value and counting value.
    

e. Input modes selection: IN-A, IN-B

F. Output Mode selection: N, F, C, R

C. Modify set point(value):

 first press “      ” key to convert to “SET2”, and follow below steps:

      ENTER:  press “      ” key to enter into set value modifying parameter, by entering, the highest digit will be flashing.
      SETTING: press  “      ” key to shift to the digit you want to modify, press “     ” to increase value of flashing digit.
      QUIT: when value is modified, press “RST” key to quit the set point parameter, or 10s until automatically quit, counter will save the value modified.

d. Counting speed:

 performance ability to restrain counting errors as follows:

      *  3000 Hz         ≤ 3000 Hz     weak ( propitious to non-contact input)                           *  1000 Hz         ≤ 1000 Hz     common
      *  300 Hz           ≤ 300 Hz       Strong                                                                              *  30 Hz         ≤ 30 Hz     Strongest ( propitious to contact input)

7.OPERATION INSTRUCTIONS

Relay or transistor output delay time: 0~9.9s, only function for C and R auto-reset function,
Press“      ” to shift the digit, press “    ” to increase the (flashing digit) value.

press “Mode” key, then press “     ” key

press “Mode” key, then press “     ” key

press “Mode” key, then press “     ” key

Quit the menu

1. Mode “A”:  IN1: counting up input terminal (can used as independent signal input terminal)
                      IN2: GATE function; when input high voltage signals or short circuit with +12V, IN1 terminal input signals are restrained, counting value keep not 
                      changed (like “S” poition in figure “ F1 ”)      (A) must >the width of min.input signals    (S) is the width of “IN2” input signals

F1 (IN-A)

IN1

IN2

H
L

H
L

S

Counting 

value

2. Mode “B”:  IN1: counting up input terminal (can be used as independent signal input terminal)
                      IN2: counting down function, when input high voltage signals or short circuit with +12V, IN1 nput signals are changed from counting up to counting 
                      down (like “S” poition in figure “ F2 ”)      (A) must <the width of min.input signals     (S) is the width of “IN2” input signals  

F2 (IN-B)

IN1

IN2

H
L

H
L

Counting 

value

S

1. Mode “N”: when the counting value equals to set value, 
    relay or transistor output, the counting value remains 
    unchanged until manual reset or external  signal reset,after 
   reset, the counting start from zero.

2. Mode “F”: when the counting value equals to set value, 
    relay or transistor output, the counting value keep on 
    rising until manual reset or external signals reset, after 
    reset, the counting start from zero.

Manual reset or 
external signals reset

Reset

Manual reset or 
external signals reset

Reset

Press “Mode” key

Содержание CRN Series

Страница 1: ...e sure the power OFF when cleaning the product Working beyond the stated power supply 90 250V AC is prohibited so as to avoid damage to the product or cause fire Make sure the OUTPUT RELAY is used at the rated load and electrical life if the contact of the output reply works against the electrical life it may melt or burned or even cause fire Install power switches and circuit breaker for power sa...

Страница 2: ...oelectric sensor 1 2 4 3 IN1 GND IN2 12V RST OUT 0V V Rotary encoder 1 2 4 3 IN1 GND IN2 12V OUTA 0V OUTB V 2 Proximity Photoelectric sensors 1 2 4 3 IN1 GND IN2 12V OUTA 0V V OUTB 5 RST 5 RST 5 48 96mm NO NC Out 2 RST 12V IN2 GND TR OUT IN1 AC 90 250V 48 48mm 72 72mm Note a IN1 and IN2 are signal input terminal related to intput mode b RST external signal reset terminal c TR OUT and TR OUT2 are t...

Страница 3: ...9s only function for C and R auto reset function Press to shift the digit press to increase the flashing digit value press Mode key then press key press Mode key then press key press Mode key then press key Quit the menu 1 Mode A IN1 counting up input terminal can used as independent signal input terminal IN2 GATE function when input high voltage signals or short circuit with 12V IN1 terminal inpu...

Страница 4: ...TH METER MODULUS By using modulus of length meter the puslse number can be transformed to measure length liquid flow position angel and height etc E G 1 for sheet cutting machines when blade cut once 10 sheets was produced set parameter SCAL 10 so the blade cut once twice three times the counter will display 10 20 30 etc E G 2 For ethene material rolling machine use rotary switch of 100P R the rol...