Preset Digital Counter

IBEST ELECTRICAL CO.,LTD

4.TECHINCAL SPECIFICATIONS

5. ELECTRICAL CONNECTION DRAWING

Power supply

90~250V AC 50/60HZ 

Power consumption

Transmitter supply

Control outpu

≤ 5VA (220v AC 50Hz)

12V DC ±10% max.50mA

Reset modes: manual reset, auto reset (0.1~9.9s), external signals reset

Reset

Relay: NO., contact capacity: AC  250V /3A or DC 30V /3A Cosφ=1
Open collector output: max. DC 30V, max. 100mA

Input signals

Contact input, volate input, transducer input
Input signals low voltage: 0~2V, high voltage: 4~30V, input resistance: 5KΩ

Input mode

Counting Up, counting down

Output mode

Ambient temperature

N, F, C, R

 0

̚

50

ć

 

35~85%(RH)

Display range

0~9999 ( 4 digit), 0~999999 ( 6 digit), 0~99999999 ( 8 digit)

Decimal point

Modulus

0.001 ~ 9999(4 digit), 0.00001 ~ 999999 (6 digit), 0.000001-99999999 (8 digit)

0.001 ~ 9999(4 digit), 0.00001 ~ 999999 (6 digit), 0.000001-99999999 (8 digit)

Insualtion strength

100MΩ/min (use 500V DC MΩ meter to measure)

Withstand voltage

AC 2000V, 50/60 Hz (1m)

Single Proximity/Photoelectric sensor

1

2

4

3

IN1

GND

IN2

+12V

RST

OUT

0V

+V

Rotary encoder

1

2

4

3

IN1

GND

IN2

+12V

OUTA

0V

OUTB

+V

2 Proximity/Photoelectric sensors

1

2

4

3

IN1

GND

IN2

+12V

OUTA

0V

+V

OUTB

5

RST

5

RST

5

48×96mm

NO

NC

Out 2

RST

+12V

IN2

GND

TR.OUT

IN1

̚

AC 90~250V

48×48mm / 72×72mm

Note:

a. IN1 and IN2 are signal input terminal, related to intput mode
b. RST: external signal reset terminal.
c. TR. OUT and TR.OUT2 are the 1st and 2nd transistor or open 
    collector output termincal.
d. OUT1 and OUT2 are the 1st and 2nd relay output terminal
e. If the connection drawing doesn’t correspond to the drawing 
    on the product, please according to thedrawing on the product.

Note:

a. IN1 and IN2 are signal input terminal, related to intput mode.
b. RST: external signal reset terminal (effective at high voltage)
c. OUT is relay output terminal.
d. TR. OUT is dynatron open collector output terminal.
e. If the connection drawing doesn’t correspond to the drawing 
    on the product, please according to thedrawing on the product.

IN1

Out 1

NO

NC

NO

NC

Out 2

GND

RST

+12V

TR.OUT1 TR.OUT2

̚

AC 100~240V

IN2

6. INSTRUMENT DIMENSION AND  INSTALLATION HOLE DIMENSION( unit: mm)

W

H

D

L

C

a

b

MODE

DIMENSION

INSTALLATION HOLE DIMENSION

a × b

˄PP

W × H(mm)

C × D × L(mm)

CRN-R1(2)8

48 × 96

(44) × (92)

43 × 91× 112

Содержание CRN Series

Страница 1: ...e sure the power OFF when cleaning the product Working beyond the stated power supply 90 250V AC is prohibited so as to avoid damage to the product or cause fire Make sure the OUTPUT RELAY is used at the rated load and electrical life if the contact of the output reply works against the electrical life it may melt or burned or even cause fire Install power switches and circuit breaker for power sa...

Страница 2: ...oelectric sensor 1 2 4 3 IN1 GND IN2 12V RST OUT 0V V Rotary encoder 1 2 4 3 IN1 GND IN2 12V OUTA 0V OUTB V 2 Proximity Photoelectric sensors 1 2 4 3 IN1 GND IN2 12V OUTA 0V V OUTB 5 RST 5 RST 5 48 96mm NO NC Out 2 RST 12V IN2 GND TR OUT IN1 AC 90 250V 48 48mm 72 72mm Note a IN1 and IN2 are signal input terminal related to intput mode b RST external signal reset terminal c TR OUT and TR OUT2 are t...

Страница 3: ...9s only function for C and R auto reset function Press to shift the digit press to increase the flashing digit value press Mode key then press key press Mode key then press key press Mode key then press key Quit the menu 1 Mode A IN1 counting up input terminal can used as independent signal input terminal IN2 GATE function when input high voltage signals or short circuit with 12V IN1 terminal inpu...

Страница 4: ...TH METER MODULUS By using modulus of length meter the puslse number can be transformed to measure length liquid flow position angel and height etc E G 1 for sheet cutting machines when blade cut once 10 sheets was produced set parameter SCAL 10 so the blade cut once twice three times the counter will display 10 20 30 etc E G 2 For ethene material rolling machine use rotary switch of 100P R the rol...

Отзывы: